Menus
22
zappi
operation and installation manual
Advanced Menu
Advanced
Menu Options
Description
Supply Grid…
Device…
Phase:
(single phase)
Phase
Rotation:
(three phase)
Sets the supply phase to use for this device – see
Advanced Settings (page
28
) for more information
Phase Return:
Sets the phase wired into the "Neutral" input terminal
(Used where
zappi
is installed on a 230V “delta
connected” supply – the Phase Return will normally be
set to Neutral
Device Limit:
Sets the maximum available supply current to be drawn
by the
zappi
– see Advanced Settings page
2528
for
more information
Neutral Limit:
Sets the maximum neutral current for the installation.
Needed in some countries with specific regulations (e.g.
Germany)
Earthing:
Enable or disable the PE conductor checks. To be set
according to the earthing arrangement in the installation
(TN/TT or IT)
Network…
Export Margin:
Minimum level of export power which is maintained when
zappi
is diverting surplus power – see Advanced Settings
page
28
for more information
Grid Limit:
Maximum grid import power limit. When charging, the
charge power is reduced to keep import below this level.
This also applies when boosting – see Advanced Settings
Page 28 for more information
Battery:
Sets the mode for managing power when an AC battery
system is present in the installation. See Battery Storage
Systems (page 52) for more information.
Net Phases:
Allows surplus power from one phase to be used on a
different phase when multiple phases are in use. – see
Advanced Settings (page 28
25
) for more information.
Note
: The Network menu options only appear and can be configured on the MASTER device
Linked
Devices…
Devices…
Other
myenergi
devices can be wirelessly linked, this shows connected
devices and their priorities. Settings for some devices are made here – see
Linking Devices
(page 3
4
31
)
Pairing Mode…
Puts this
zappi
in pairing mode so it can be linked to another device – see
Linking Devices
(page 34
31
)
Channel…
RF Channel:
Sets the radio frequency channel number used when
linking other devices – see Linking Devices (page 33)
Set Master…
Sets the
zappi
device to be master (
✓
is shown) or slave – see
Linking
Devices (Page 33)
Reset Settings…
Clear all linked device settings – see Linking Devices (Page 33)