Thermostat Heat and Cool Modes (HEAT / COOL)
Configure COOL / HEAT Thermostat Menu Descriptions
Value Range
Select Output to Configure (1-6):
1-6
Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF
5-ROOT, 6-RESET, 7-CYCLIC
2 or 3
Select Thermostat Temp Sensor (1-6):
1-6
Select Setpoint Temperature (-40-300F):
-40 - 300
Enter Hysteresis / Dwell Degrees (1-99):
1-99
Use HEAT or COOL mode to provide thermostat
heating or cooling or provide temperature alarming
for motors or refrigeration.
Setpoints from -40F to 300F (or celsius equivalent)
are supported by the controller.
Programmable Hysteresis and Dwell temperature
from (0 - 99F) (or celsius equivalent) is also
provided to adjust the run time and depth of
temperature cycling required.
The inputs sensor selection for these modes will
allow multiple thermostats to be controlled by the
same temperature input if desired for controlling
multiple output devices from one sensor.
The controller will print
Saving to Memory
when
the settings are committed to memory.
MAXDTC-BT User Manual - Rev A
www.mydtcstore.com
9