![Mydtcstore MAXDTC2-BT Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/mydtcstore/maxdtc2-bt/maxdtc2-bt_user-manual_1862198008.webp)
Outdoor Reset Mode (RESET)
Outdoor reset mode is used to automatically adjust the setpoint for a wood boiler based on
outdoor temperature. The controller will automatically adjust the setpoint higher when the
outside temperature gets very cold as well as reduce the setpoint when the outdoor temperature
warms up. This reduces wood consumption and enhances comfort.
Reset_setpoint = 70 + ( ( 70 - Outside Temp ) * SLOPE / 10) - Fahrenheit
Reset_setpoint = 21 + ( ( 21 - Outside Temp ) * SLOPE / 10) - Celsius
Here is a link to a spreadsheet for comparing calculated setpoints vs outside temperature and
the slope setting:
https://docs.google.com/spreadsheets/d/1uj_T8KyJOKdhtVgsXukm8cQ8C06riTzFjORUtoDk3Fk
/edit?usp=sharing
Configure Outdoor Reset Menu Descriptions
Value
Range
Select Output to Configure (1-6):
1-6
Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF
5-ROOT, 6-RESET, 7-CYCLIC
7
Select Outside Ambient Temp Sensor (1-6):
1-6
Select Boiler Temp Sensor (1-6):
1-6
Enter Slope Value (x10) (1-99):
1-99
Enter Reset Hysteresis (1-99):
1-99
Enter Maximum Boiler Temp (0-255):
0-255
Enter Minimum Boiler Temp (0-255):
0-255
MAXDTC-BT User Manual - Rev A
www.mydtcstore.com
8