46
17. ADDITIONAL FUNCTIONS
17-2. Folding Stopper Operation Mode Setting Function
This function is used for setting the movements of the folding stoppers of folding plates 1 and 2
when the power is turned on. There are two modes; “Refold mode” and “Folding stopper fixed
mode”.
Refold mode
This function starts this unit at the last settings used when the power is turned on. When set to this
mode, the unit will automatically be set to the following settings when the power is turned on.
If the folding stopper position has been corrected, be sure to register the corrected data to save it. Otherwise,
the corrected data will be erased when the power is turned off.
Note
Note
Setting
Paper size
Folding mode
Stacker roller position
Processing speed
Folding stopper position
Before refold mode setting
Standard paper is automatically
detected.
For non-standard paper, nothing is
displayed on LCD. (Paper length
needs to be registered.)
Set to single fold as in shipment.
(Single-folding mode lamp lights up.)
Automatically set.
Set to same processing speed as when
power is turned off.
Moves to home position and stops.
(Resetting of position, registration
required.)
After refold mode setting
Standard paper is automatically
detected.
When non-standard paper length is
r e g i s t e r e d , r e g i s t e r e d d a t a i s
displayed on LCD.
Set to same folding mode as when
power is turned off.
(The folding mode display lamp lights
up.)
Set to same stacker roller position as
when power is turned off.
Set to same processing speed as when
power is turned off.
After moving to home position, moves to
position set when power is turned off.
Folding stopper fixed mode
This function allows control panel settings to be skipped when folding paper under the same
conditions all the time (paper size, folding mode, stacker roller position, processing speed, folding
stopper position). When set to this mode, the unit will always be automatically set to the same
conditions when the power is turned on, allowing paper folding to be started without the need for
control panel settings.
When set to this mode, normal operations will not be possible. However, the folding stopper position and
interval function can be changed.
If the folding stopper position has been corrected, be sure to register the corrected data to save it. Otherwise,
the corrected data will be erased when the power is turned off.
When set to this mode, the standard folding lamp and custom folding registration lamp will not light up.
Note
Note