24
-1
1
2
3
4
5
6
0
6
0
1
2
3
4
5
6
9. STANDARD FOLDING OF STANDARD PAPER
Set the paper feed pressure adjusting
lever to “0”.
Move the adjusting lever to the left and right while
pulling upwards.
If paper slips and mis-feed occurs, increase the paper
feed pressure by one from “0” to “1”.
Paper feed pressure increases as the scale value
increases.
If several sheets of paper are fed at the same time
(double-feed), decrease the paper feed pressure by
one from “0” to “–1”.
6
Top cover
Separating pressure adjusting dial
Open the top cover, and set the
separating pressure adjusting dial to
“0”.
After setting, close the top cover.
If several sheets of paper are fed at the same time
(double-feed), increase the paper separating pressure
gradually in steps of 0.5.
Paper separating pressure increases as the scale
value increases.
7
P r e s s t h e s p e e d k e y t o s e t t h e
processing speed.
When using thin and flimsy paper, setting the
maximum processing speed causes problems such as
paper jam and deformed folding. Set a lower
processing speed.
When the power is turned on, the last processing
speed used is displayed.
8
Press the test key to perform test folding.
When the test key is pressed, “WAIT” is displayed on the LCD, and the folding stopper starts moving to the set position.
When it completes moving, the message changes to “TEST RUN”, and test folding starts.
Test folding feeds two sheets of paper and allows the finish to be checked.
Test folded paper are not counted in the number of sheets processed.
9
If the unit does not start even if the test key is pressed, the automatic paper size detection function may not
be working. Check if the paper feed guides are at the appropriate paper size on the scale.
When the automatic paper size detection function starts working, the paper size will be displayed on the
LCD.
(Refer to “7-3. Automatic Detection of Paper Size” (
☞
p.19).)
Note
Note
Folded paper
Paper feed pressure adjusting lever