AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020806
35
The choice of setting options varies depending on the operating mode.
The following unit settings are only possible in the web interface and cannot be carried out on the
AC•THOR display.
The following parameters can be set on the web interface in operating mode M3 (6kW/18 kW).
Control tolerance:
This value defines the reaction sensitivity of the
AC•THOR
relay to changes in
the power input. The second heating rod is switched by the relay.
Load at relay:
The control range of the
AC•THOR
is extended by this adjustable threshold value.
When the threshold value is reached, the load on the relay is switched on and the
AC•THOR
starts
controlling again from 0 watts at the controlled load.
Load measurement on relay with my-PV Meter:
As an alternative to the static definition of the
load at the relay, it can also be measured with a my-PV Meter. To do this, enter the device ID of the
my-PV Meter. This can be found on the device.
TIP: If the
AC•THOR
control is also carried out with a my-PV Meter (recommended),
a static IP address should be assigned for it and the control type "my-PV Meter
Manual" should be selected. Otherwise, the
AC•THOR
could confuse the signal
source!