AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020806
6
MEC electronics Manual
LAN
(RJ45, Ethernet)
Approved for meter type MECmeter.
Modbus TCP
LAN
(RJ45, Ethernet)
A description of this open protocol is available in a separate document,
which will be provided on request.
QCELLS (Modbus RTU)
Modbus RTU
(RS485, A B
GND)
The control signal is received via Modbus RTU (RS485, A B GND)!
Connection diagram according to chapter 9.
When controlling via Modbus RTU, the operating mode M7 cannot be used!
Tested by my-PV with Q.VOLT HYB-G3 5.0 kW 1P, baud rate 115200.
According to information from Q CELLS, the devices in the Q.VOLT HYB-G3
series support RTU communication.
The correct communication connection to the Q.VOLT HYB-G3 inverter can
be found in the Q CELLS manual.
RCT Power Manual
LAN
(RJ45, Ethernet)
-
Slave
LAN
(RJ45, Ethernet)
Cannot be selected manually. See chapter “
SMA Direct meter
communication
Auto / Manual
LAN
(RJ45, Ethernet)
This control type is available for the SMA Energy Meter and SMA Sunny
Home Manager devices.
If this control type is carried out by the Sunny Home Manager, the
superordinate energy planning for the my-PV device is then not given. There
is also no visualization in the Load Balance. However, the power control is
then carried out significantly faster than with the control type "SMA Home
Manager".
SMA Home Manager
LAN
(RJ45, Ethernet)
The power signal which the SMA Sunny Home Manager gives the my-PV
device depends not only on the feed-in, but also on the superordinate
energy planning.
SolarEdge Manual
Alternative:
SolarEdge Synergy for
2-unit Manual
SolarEdge Synergy for
3-unit Manual
LAN
(RJ45, Ethernet)
Modbus TCP must be enabled on SolarEdge.
The communication usually works either via port 502 or 1502.
According to the latest information from SolarEdge, this control only works
when connected via LAN, not WLAN.
Solax (Modbus RTU)
Modbus RTU
(RS485, A B
GND)
The control signal is received via Modbus RTU (RS485, A B GND)!
Connection diagram according to chapter 9.
When controlling via Modbus RTU, the operating mode M7 cannot be used!
Tested by my-PV with X1-Hybrid5.0-G4, baud rate 115200.
According to information from Solax, the G4 units support RTU
communication.
The correct communication connection to Solax can be found in the Solax
instructions.
Steca Auto
LAN
(RJ45, Ethernet)
-
Sungrow Manual
LAN
(RJ45, Ethernet)
Works with Sungrow devices that communicate via Modbus TCP.
Varta Auto / Manual
LAN
(RJ45, Ethernet)
-
Victron Energy 1ph /
3ph Manual
LAN
(RJ45, Ethernet)
With Modbus control, the excess power control can be selected according to
one or three phases.
TIP: For many of these
and other manufacturers
there are separate instructions
for the required settings. More information about compatible manufacturers can be
found
When controlled by an inverter, a feed-in meter is required in the system. The query of the
inverter otherwise provides no data.