background image

5. SITE REQUIREMENTS

The installation must be in accordance with Water 

Regulations Advisory Service (www.wras.co.uk).

Minimum running water pressure: 0.1 bar, but will 

operate better at a minimum of 0.5 bar.

Maximum running water pressure: 5 bar. Maximum 

static water pressure: 10 bar.

For your shower to perform well you should ensure 

that the pressure is as specified and a minimum flow 

of 5 litres per minute is available at both hot and cold 

inlets.

If the water supply is fed by a gravity system then 

the supply pressure should be verified to ensure the 

conditions of use are appropriate for the valve.

NOTE:  Water Regulations requires the handset to 

be ‘constrained by a fixed or sliding attachment so 

that it can only discharge water at a point not less 

than 25mm above the spill over level of the relevant 

bath, shower tray or other fixed appliance’. A double 

check valve, or similar, MUST be fitted in the supply 

pipe work to prevent back-flow.

The pressure at both the hot and cold water 

supplies to the mixer valve should be the same, 

and the installer should ensure that the flow is not 

affected by other taps elsewhere in the house. It is 

very important that for use in any mains pressure 

systems an expansion tank and a pressure reducing 

valve has been fitted to ensure the pressure does 

not exceed 5 Bar. 

This should be confirmed by the installation 

engineer or competent person  before installation. 

WATER TEMPERATURE REQUIREMENTS

Maximum hot water temperature = 80°C, 

Recommended maximum = 65°C.

Minimum hot water temperature = 55°C

Maximum cold water temperature = 20°C

TEMPERATURE ADJUSTMENT RANGE

The mixed water temperature can be adjusted from 

cold through to hot. There is a safety stop preset at a 

set temperature of about 38°C. Always test the water 

temperature prior to using the shower.

In the event of failure of cold water system, the mixer 

valve automatically reduces the flow of hot water to 

prevent scalding. It will only operate again once the 

flow of cold water has been resumed.

6. SITING OF THE MIXER VALVE

Position the mixer valve so that all controls can be 

comfortably reached whilst using the shower.

NOTE:  Easily accessible suitable service valves 

(complying with Water Regulations Advisory 

Service www.wras.co.uk), MUST be fitted as close 

as practical to the valve, on the hot and cold water 

supplies to the shower as an independent means 

of isolating the water supplies should maintenance 

or servicing be necessary. These valves should not 

restrict the flow.

Содержание Atmos 2 Way

Страница 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos 2 Way Thermostatic Mixer Valve for Round and Square Valve Options...

Страница 2: ...umof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTANT Beforeinstallingw...

Страница 3: ...RTANT This Step by Step guide should be retained after installation Concealing Plate Nut Cover Please make sure ALL components are included before starting the installation Description Quantity MixerV...

Страница 4: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Страница 5: ...Itis veryimportantthatforuseinanymainspressure systemsanexpansiontankandapressurereducing valvehasbeenfittedtoensurethepressuredoes notexceed5Bar Thisshouldbeconfirmedbytheinstallation engineerorcompe...

Страница 6: ...thesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto thehigherpressuresupplytothevalve Thisisbest donebytestingeachonetofindoutwhichgivesthe bestresults...

Страница 7: ...pointyoumaywishtofitthepipeworkto oultetspriortoanytiling 5 Thevalveshouldbeattachedfirmlybetween75mm and95mmbelowthefinishedsurfacetoallowthe coverplatetofitneatly usingthetwofixingholeson thevalve P...

Страница 8: ...ntothemixer valveuntilflushwiththetiles Fig5 NOTE Beforeassemblingthevalvecontrolsidentify allthepartsandcheckthatboththeredmarkingson thecontrolshaftofthethermostaticcontrolareinline 11 Fittheon offk...

Страница 9: ...becheckedtoconfirmthe waterisolationperformscorrectly Runthevalveat the38 Cstopposition Checkthewatertemperature 5 Turnoffthefeedofcoldwaterusingtheisolation valve Thewaterflowshouldfalltoaverylowflow...