1.2.

Features

 

Power  350VA;  24Vac  or  28  Vac  individually

selected  and  protected,  transmitted  through  each
port.

 

Slide-switch  to  set  each  port  to  Pass-Thru  Mode

(500022) or Power-Thru Mode (500024/500029).

 

Slide-switch to set each port to 24Vac, or 28 Vac or

“OFF”.

 

Auto-resettable fuses on each port.

 

Seamless integration with 500000R, 500022, 500024

and 500130.

 

Pin configuration chart on unit.

 

2U rack height.

 

Remote-power LED indicators.

 

cUL, FCC, CE compliance.

 

5 year warranty

Содержание 500136-Eur

Страница 1: ...P N 94 000668 A SE 000669 A Passive CCTV Power Integrator Hub 24VAC 500136 US 500136 UK 500136 Eur Installation Guide ...

Страница 2: ...iew 4 1 1 Description 4 1 2 Features 5 2 Technical Specifications 6 3 Installation Procedure 8 3 1 Parts List 8 3 2 Product Overview 9 3 3 Pre Installation Checklist 10 3 4 Physical Installation 11 3 5 Installation Procedure 13 4 Troubleshooting 19 5 Distance Tables 21 6 Product Warranty Policy 23 ...

Страница 3: ...articularly the outdoor camera must be of type Integral Isolated Camera Power The mentioned equipment must be manufactured and connected in respect to all local safety codes ensuring that the grounds of adjacent devices are connected to the same local ground net This installation should be carried out by qualified service personnel and should conform to all local safety codes CAUTION To reduce the...

Страница 4: ... need to install multiple cables for more efficient cabling in the security video environment The product features a built in 16 channel 350VA CCTV power supply that supplies 24Vac or 28Vac power to each CCTV camera and works in conjunction with MuxLab s 500000R 500009 500022 500023 500024 500029 500120 500122 and 500130 Each hub port features two slide switches one for remote power and one for Po...

Страница 5: ...ough each port Slide switch to set each port to Pass Thru Mode 500022 or Power Thru Mode 500024 500029 Slide switch to set each port to 24Vac or 28 Vac or OFF Auto resettable fuses on each port Seamless integration with 500000R 500022 500024 and 500130 Pin configuration chart on unit 2U rack height Remote power LED indicators cUL FCC CE compliance 5 year warranty ...

Страница 6: ...r Thru Mode 500024 500029 Number of twisted pairs Two 2 Three 3 Max Distance 24VAC Based on 10 voltage drop at camera Longer distances may be achieved 28 VAC 5 VA 350 ft 107m 10 VA 175 ft 53m 20 VA 90 ft 30m 30 VA 60 ft 20m 5 VA 518 ft 170m 10 VA 259 ft 85 m 20 VA 130 ft 43 m 30 VA 86 ft 28 m Maximum Power Rating 350 VA 60 Hz Voltage Selector Switch Sets port to 24 Vac or 28 Vac or OFF Factory def...

Страница 7: ...ls Sixteen 16 RJ45 jacks Port Configuration Switch Sets each port to Pass Thru Mode 500022 or Power Thru Mode 500024 500029 RJ45 Pin Configuration Signal 500022 Mode 500024 500029 Mode Reverse polarity Power A 1 3 1 3 5 sensitive Power B 2 6 2 4 6 Control 4 Not used Control 5 Not used Video BNC Center Tip 7 T same as 500000R 7 T same as 500000R Video BNC Ground Ring 8 R same as 500000R 8 R same as...

Страница 8: ...Passive CCTV Power Integrator Hub comes with the following parts Please verify that all pieces are present before proceeding Base Unit Factory configuration Power Thru Mode 500022 Voltage Selector Switch OFF Power cord for US UK or Continental Europe Two 2 L brackets and four 4 Philips 4 40 screws Installation Guide ...

Страница 9: ...24V OFF 28V 24V O FF 28V 24V OFF 28V 24V O FF 28V 24V OFF 28V 24V O FF 28V 24V OFF 28V 24V O FF 28V 24V OFF 28V 24V O FF 28V 24V OFF 28V 24V O FF 28V Figure 1 Front panel Product Label ON THIS EQUIP MENT T O MOISTUREORRAIN OR E LECTRICAL S HOCK DO NOTEX POSE CAUTION T O RE DUCETHERIS K OFFIRE IN S IDE REF ER SE RVICING TO QUALIFIED P ERSONNEL DO NOTREMOVECOVE R NO USER SERVICEABLEPART S CAUTION TO...

Страница 10: ... port and is connected to the DVR via coaxial cable and features a switch at each port to select between Pass Thru Mode 500022 compatible or Power Thru Mode 500024 500029 compatible depending on the cabling configuration 3 The Passive CCTV Power Integrator Hub works in conjunction with MuxLab s other CCTV products including the 500000R 500009 500015 500022 500023 500024 500029 500120 500122 and 50...

Страница 11: ...fault switch setting of each port is Pass Thru Mode 500022 The factory default setting for remote power is OFF 1 MuxLab s Passive CCTV Power Integrator Hub comes with two 2 L brackets and four 4 Philips 4 40 screws for standard 19 rack mounting Select the final destination for the product and attach the L brackets as shown in the diagram below Figure 3 L brackets installation ...

Страница 12: ... MuxLab Inc Passive CCTV Power Integrator Hub Installation Guide Page 12 2 If the product fits in the relay rack install the unit using standard rackmount screws Figure 4 Rack mount installation ...

Страница 13: ...ease verify that the cable lengths between the hub and cameras are within MuxLab specifications 2 Ensure that the Passive CCTV Power Integrator Hub is properly grounded in accordance with local safety codes On the rear panel a grounding terminal is provided Refer to the instructive figures below Power up the unit Crimp the terminal on the tip of green cable gage 18 or better Fit the terminal on th...

Страница 14: ... the front of the Passive CCTV Power Integrator Hub fig 5 Ensure wiring is that EIA 568 and straight through polarity is respected between the CCTV balun and the hub The use of other Cat5e 6 connection hardware such as patch panels and 110 blocks is supported Figure 5 Camera connection Port Switch Settings 5 For each camera port determine whether video power and or control are to be transmitted vi...

Страница 15: ...sted pairs are used for remote power thus supporting greater distance 7 In order to transmit video on one 1 twisted pair remote power on two 2 twisted pairs and control on one 1 twisted pair set the port switch to Pass Thru Mode 500022 using a small flathead screwdriver as shown in fig 6 Ensure that there is a CCTV Pass Thru Balun 500022 at the camera Figure 6 Port Setting Pass Thru Mode 500022 8 ...

Страница 16: ... Figure 8 Port Power Setting Set to 24Vac 9 Verify that the green LED indicator is ON fig 8 If so the port is ready for use If not the port fuse may be in FAULT status In order to reset the fuse to ACTIVE status slide the power switch 24 OFF 28 to the middle position wait 3 5 seconds and then slide it back to the desired position Verify again that the green LED indicator is ON If not verify the Ca...

Страница 17: ... that the distance between the camera and the hub is within the distance specifications for sending PTZ control over twisted pair Consult the PTZ equipment vendor for maximum distances Please ensure that the port switch is set to Pass Thru Mode 500022 When the port switch is set to Pass Thru Mode 500022 one 1 twisted pair is used for PTZ control For optimum results it is recommended to use control...

Страница 18: ...onnect two 2 wires between the PTZ controller and the Control terminals on the hub fig 9 Figure 10 PTZ control connection 13 Power on the CCTV equipment cameras remote power supply PTZ controller The following diagram shows a typical configuration Figure 11 Typical Configuration ...

Страница 19: ...nfiguration Check pin configuration and verify straight through wiring Defective CCTV Balun Change CCTV baluns for another pair Poor image quality distortions interference EMI interference Wires reversed on signal pair on one side Split pair Check that wiring is not too close to transformers and lighting ballasts Make sure that the wires on the signal pair are not reversed on one side Check if the...

Страница 20: ... cable by higher grade No power or intermittent power at camera Wrong pin configuration Check wiring Distance exceeded Verify distance specifications for remote power Move power closer to camera PTZ controls not responding Wrong pin configuration Check wiring When contacting your nearest MuxLab dealer or MuxLab Technical Support please have the following information ready Unit model number Cabling...

Страница 21: ... a port on the Passive CCTV Power Integrator Hub is set to Pass Thru Mode 500022 or Power Thru Mode 500024 500029 Pass Thru Mode 500022 Two 2 Twisted Pairs Voltage Pcam W Vcam 1 min V Dist Spec 2 max Feet Dist Spec 2 max m 24 VAC 24Vac camera 5 21 60 346 113 10 21 60 173 57 20 21 60 86 28 30 21 60 58 19 28 VAC 24Vac camera 5 21 60 922 302 10 21 60 461 151 20 21 60 230 76 30 21 60 154 50 ...

Страница 22: ... 259 85 20 21 60 130 43 30 21 60 86 28 28 Vac 24Vac camera 5 21 60 1382 454 10 21 60 691 227 20 21 60 346 113 30 21 60 230 76 Notes 1 Distances are specified for temperatures of 20 o C to 30o C 2 Maximum distances based on 10 loss of voltage For 28VAC a 24VAC camera was used 3 Distances specified are 90 of distances calculated 4 If 22AWG gage wire is used there would be an increase in distance of ...

Страница 23: ...ion number RMA issued by its Customer Service Department and a proof of purchase date If this product is delivered to MuxLab by mail you agree to assume risk of loss or damage in transit to prepay shipping charges to the warranty service location and to use the original shipping container or equivalent THE ABOVE LIMITED WARRANTY IS THE ONLY WARRANTY COVERING YOUR MUXLAB PRODUCT THERE ARE NO OTHER ...

Страница 24: ...ve products are not returned Product more than six months old including shelf life The defective unit must be returned prepaid to MuxLab and then the unit will be repaired or if repair is not possible replaced by an equivalent unit and returned to the customer within one 1 month of receiving any returned product There is no charge for repair parts and labor during the full warranty period Items De...