29  

The preset management enables to store eight different set-ups of all func-
tion settings which have been set within the whole iCLOCK system menu, as 
so-called ‚Presets‘. When switching over the presets, all individual function 
settings will be switched at one time. Additionally, the preset management 
stores intermediately the whole current system status permanently in a so-
called ‚System-Preset‘. This system-preset works fail-safe, which provides an 
automatic function-setting-recovery after, e.g., a mains failure!

When switching on your iCLOCK or iCOCKdp for the first time, all presets 
contain of the same factory default settings as described in the previous 
chapters of this manual. This system condition is equal to this one after a 
software-reset.

After normal switching on the unit, the last system status stored in the 
system-preset will be loaded. If this is different compared to the settings of 
the last active preset, the selected setting under the function OPERATION 
will be marked with a (*). If you want to work with the current system sta-
tus, you have to store it in one of the eight available presets. If you prefer 
to work with that preset, which was active before last switching off / on the 
unit, you have to load this preset separately.

But if the GPIO preset control is active, your iCLOCK or iCLOCKdp starts 
using the preset which was previously active, no matter if the system-preset 
consists of different settings, which are due to changes before switching of 
the unit.

PRESET 

(function) 

PRESET Within this function menu you can confirm and activate the settings 
you have choosed within the function menus OPERATION and NAME.      
Only after this step, the choosed setting will be activated.

GO,  SURE ?

 (setting) 

GO enables the setting which is choosed within the function menus OPERA-
TION and NAME. When the ENTER button has been pressed, a confirmation 
request (SURE?) will be displayed. If this request is confirmed by pressing 
the ENTER button again, the choosed setting is active.

OPERATION 

(function) 

OPERATION Here you can store and load presets as well as reload the 
system‘s default preset.

When a setting within this function menu is marked with a (*), the last 
preset settings are changed, but have not been stored!

SAVE

 (setting) 

SAVE stores all current system settings under one of the available eight 
preset  numbers  (01 –  08). The previously stored settings of this preset will 
be deleted.

LOAD

 (setting) 

LOAD loads and activates the choosed preset (number).

SET DEF

 (setting) 

SET DEFAULT reloads the factory default settings for the active preset.

P R E S E T

O P E R A T I O N

N A M E

N U M B E R

G O

L O A D

P R E S E T 0 1

0 1

  

|

<

|

<

PRESET

Preset Management

This functionality is available from software versions, V2.10 and V2.11, or 
higher. Does your iCLOCK or iCLOCKdp not include one of these software 
versions, please contact your local MUTEC dealer or distributor for an update.

Software V2.11 offers in combination with the new optional iC-ALARM/GPI 
interface the possibility to switch over different presets externally via GPIO 
control. If you are working with software V2.10, you need to switch over 
the presets on the PRESET page.

Software Reset

If a software-reset has been execut-
ed with help of the RESET function 

on GLOBAL 2/4 page, all presets will be 
deleted and the factory default settings are 
loaded again.

!

Entering the Preset Page

Starting from the main page, press 
the button pointing downwards 

for one time to reach the PRESET page 
immediately.

!

Содержание iclock

Страница 1: ...REDUNDANT MULTIPLE CLOCK SYNTHESIZER AND VIDEO REFERENCE GENERATOR VERSION 2 23...

Страница 2: ......

Страница 3: ...ranty claim proves to be justified the product will be returned freight prepaid by MUTEC GmbH within Germany Outside Germany the product will be returned with the additional international freight char...

Страница 4: ......

Страница 5: ...Generator 18 Configuring the Word Clock Outputs 20 Configuring the AES EBU Outputs 21 Configuring the S PDIF Outputs 23 Setting System Functions Pull Up Pull Down Varispeed etc 25 Preset Management 2...

Страница 6: ......

Страница 7: ...nals This applies also to external clock frequency changes e g from 44 1kHz to 48 0kHz or reference clock changes e g from video to GPS or AES11 Even if all external references are lost iCLOCK synthes...

Страница 8: ...tion of input assignment at the universal inputs SoftReLock functionality for recurring reference signals CYCLESYNC functionality for automatically re synchronization Drop out compensation of incoming...

Страница 9: ...chaining devices see the Switching off the Termination of the universal Clock Inputs section in the appendix 3 ALARM OUT The iC ALARM output is optionally available item no 8005 065 Refer to the EXTE...

Страница 10: ...nd B this allows for example for a simple documentation of the connected devices 10 RS485 This interface port is provided for programming the iCLOCK and updating the device firmware A software for rem...

Страница 11: ...which may be located on the outside or inside of the device For devices which have no termination of the Word Clock input e g RME Hammerfall with Word Clock i o or Alesis BRC you can use an additional...

Страница 12: ...nch connectors on both ends The specifications stipulate a specific cable resistance of 75 ask your retailer for a confirma tion of this value when purchasing the cables Cables for High Clock Rates Es...

Страница 13: ...R M A T L E V E L T E R M O U T2 4 4 1 k W O R D C L K 2 5 V 7 5 R W C LK S F R E Q F O R M A T L E V E L T E R M O U T3 4 4 1 k W O R D C L K 2 5 V 7 5 R W C LK S F R E Q F O R M A T L E V E L T E R...

Страница 14: ...ging parameter values and not for moving between menu pages 4 When the horizontal arrow has been positioned in front of the parameter to be changed pressing the up down buttons will first change to th...

Страница 15: ...between two externally applied clock signals or an auto matically or manually performed change from an external to an internal clock source or vice versa When the change occurs the LOCK indicator of...

Страница 16: ...ian in charge immediately The message is displayed only if the iCLOCK is equipped with a redundant power supply iCLOCKdp version item no 8015 046 OUTPUTs function Here the set clock rates of all outpu...

Страница 17: ...1id compliant signals can be applied In addition S PDIF signals can be applied to this input and be used for synchronization Refer to the Synchronizable and Generatable Clock Rates section in the appe...

Страница 18: ...deo signal routing The factory default is INTERN INTERN setting INTERNAL links the video generator to the internal reference clock oscilla tor An extraordinary feature of iCLOCK is that the synthesize...

Страница 19: ...ignal In this mode the synthesizer synchronizes to the input video signal to pro vide the output of phase locked audio clock signals FORMAT function FORMAT This function allows for selecting the video...

Страница 20: ...FIELD RATE 48Hz PAL FR setting PAL VIDEO FRAME RATE 25Hz PAL FI setting PAL VIDEO FIELD RATE 50Hz NTSC FRBW setting NTSC VIDEO FRAME RATE 30Hz NTSC FIBW setting NTSC VIDEO FIELD RATE 60Hz 20 NTSC FRC...

Страница 21: ...MC conditions in the studio EMC electromagnetic compatibility Due to the internal signal phase corrections the synthesizer can re lock temporarily when switching AES EBU clock frequencies This does no...

Страница 22: ...te 2 bits 3 4 and 5 of the clear frame signal of the selected AES EBU output pair The factory default is 24BITs 16BITs 18BITs 20BITs 24BITs setting One of four word lengths between 16 and 24Bits are a...

Страница 23: ...TRIBUTION This setting allows for forwarding an input S P DIF or AES3 11 signal to the S P DIF output pair using a hardware bypass As no adjustments can be made in this mode the other functions and pa...

Страница 24: ...g the reference status stored in the channel status bits byte 3 bits 4 5 of the clear frame signal of the selected S P DIF output pair The factory default is LEVEL 3 LEVEL 3 setting With the LEVEL 3 v...

Страница 25: ...well as by instabilities of the synthesizer signal caused by clock source deviation Entering varispeed values and moving the cursor 0 ENTER Enable the varispeed function by pressing the up down cursor...

Страница 26: ...nd a subsequently selected clock source can be selected here FREEZE function FREEZE This function allows for blocking the four cursor buttons This is convenient for protecting the iCLOCK from unauthor...

Страница 27: ...common If a function is edited on any AES menu page any changes will be applied to the same function on the other AES menu page or output The factory default is SINGLE SINGLE setting SINGLE allows for...

Страница 28: ...ersion 1 ON 2 N A one active power supply iCLOCK dp 1 ON 2 ON two active power supplies OK setting The respective power supply is active N A setting NOT AVALABLE This message shows that the respective...

Страница 29: ...n menus OPERATION and NAME Only after this step the choosed setting will be activated GO SURE setting GO enables the setting which is choosed within the function menus OPERA TION and NAME When the ENT...

Страница 30: ...nce more will load the selected preset and reboot the system The number of the selected preset 01 08 will be displayed under NUMBER and the GO parameter will appear If no user input occurs while SHURE...

Страница 31: ...elect one of the PRESET01 08 memories by their preset number or name using the up down keys and confirm by pressing the ENTER key Press the ENTER key twice to switch to the PRESET function Press any u...

Страница 32: ...ANHANG ANHANG ANHANG 88 32...

Страница 33: ...internally or by an external source Doing this the powerful synthesis process enables additio nally as an outstanding feature the use of the pull up down and varispeed functions simultaneously Thus an...

Страница 34: ...3 in same procedure Note If a reference slot is set to NO REF the sys tem skips this slot and synchronizes the next activated slot or the internal video reference generator The system will be locked a...

Страница 35: ...LOCKdp ALARM OUT 3 Loss of the internal reference oscillator Every of the above mentioned operating conditions activate also the red front panel LED ALARM set The relays are normalled when the describ...

Страница 36: ...tions work faultlessly If a disturbance occurs the according relay faills instantly The output contacts supply a max switching power of 30W with 30V 1A DC AC peak The type of the used relays is called...

Страница 37: ...x128 4096 0 5644 8 6144 0 x256 8192 0 11289 6 12288 0 x512 16384 0 22579 2 24576 0 PILOT TONE Clock Rates Type PAL SECAM Hz NTSC Hz Film Hz Color Frame Rate 25 29 97 24 Color Field Rate 50 59 94 48 Bl...

Страница 38: ...ot 3 b conductor cold AES EBU XLR Output AES EBU XLR Input S P DIF Cinch Input Output 1 Audio signal 2 Audio ground 1 2 2 1 AES11 CLOCK RATES Dividers Factors Basic Clock 32 0kHz Basic Clock 44 1kHz B...

Страница 39: ...transfering the video signal of the internal video reference generator simultaneously Two Jumpers are put on two 2 pin sockets J16 and J17 Removing the jumpers from the 2 pin sockets will split up th...

Страница 40: ...ble in pairs Output levels 2 5V p p 75 output impedance 75 3 5V p p 75 output impedance 22 Generatable clock rates 36 audio clock rates 2 DSD clock rates 6 pilot tone clock rates 4 GPS atomic clock ra...

Страница 41: ...Remote controlling of whole system none standard software updating programming power supply Type Internal switching power supply Input voltage 90V 260V automatic adjustment 47Hz 440Hz Power consumpti...

Страница 42: ...PRODUCT NAMES ARE REGISTERED TRADEMARKS OF THEIR RESPECTIVE OWNERS WE RESERVE THE RIGHT TO CHANGE TECHNICAL DETAILS WITHOUT PRIOR NOTICE MUTEC GmbH 2002 7045 014 WWW MUTEC NET DE FON 0049 0 30 746880...

Отзывы: