2.6 Operation Warnings

warning

caution

-5-

Make all electrical connections (e.g. conductor termination, fuses, PE connection, 
etc.) in accordance with prevailing regulations. When working with the inverter, 
adhere to all prevailing safety regulations to minimize risk of accidents.
Systems with inverters typically require additional control (e.g., switches, 
disconnects) or protective devices (e.g., fusing circuit breakers) depending 
on the prevailing safety rules.

The PH5000-T Inverter converts DC Current from PV generator into AC current. 
The inverter is suitable for mounting indoors and outdoors.
You can use the AC current generated as follows:

Energy flows into the house grid. The consumers connected, 
for example, household devices or lighting, consume the energy. 
The energy left over is fed into the public grid. When the 
PH5000-T is not generating any energy, e.g., at night, the 
consumers which are connected are supplied by the public 
grid. The PH5000-T does not have its own energy meter. When 
energy is fed into the public grid, the energy meter spins 
backwards.

Energy is fed directly into the public grid. The PH5000-T is 
connected to a separate energy meter. The energy produced is 
compensated at a rate from the electric power company.

Make sure all covers and doors closed and secure during operation.
Although designed meeting all safety requirements, some parts and surfaces 
of Inverter are still hot during operation. To reduce the risk of injury, do not 
touch the heat sink at the back of the PV-Inverter or nearby surfaces while 
Inverter is operating.
Incorrect sizing of the PV plant may result in voltages which could destroy 
the inverter. 
   Switch the rotary DC Disconnect to the Off position immediately.
   Contact installer.

All operations regarding transport, installation and start-up, including 
maintenance must be operated by qualified, trained personnel and in 
compliance with all prevailing codes and regulations.
Anytime the inverter has been disconnected from the power network, please 
be much careful as some components can retain charge sufficient to create a 
shock hazard; to minimize occurrence of such conditions, please comply with 
all corresponding safety symbols and precautions and present on the unit and 
in this manual.
In particular cases, there may still be interference for the specified application 
area despite maintaining standardized emission limit values (e.g. when 
sensitive equipment is located at the setup location or when the setup location 
is near radio or television receivers).In this case, the operator is obliged to 
take proper action to rectify the situation.
Do not stay closer than 20 cm to the inverter for any length of time.

Содержание PH50-10000T

Страница 1: ...PV Grid Inverter...

Страница 2: ......

Страница 3: ...6 4 Unpacking and inspection 8 5 Electrical Connection 14 6 Commissioning 18 7 Start up and shut down the inverter 21 8 maintenance and Cleaning 21 9 Trouble shooting 21 10 Decommissioning 23 11 Tech...

Страница 4: ...00T PH50 11000T PH50 12000T PH50 13000T PH50 15000T The manual and other documents must be stored in a convenient place and be available at all times For possible changes in this manual we accepts no...

Страница 5: ...C Abbreviation for Alternating Current DC Abbreviation for Direct Current Energy Energy is measured in Wh watt hours kWh kilowatt hours or MWh megawatt hours The energy is the accumulation of power ov...

Страница 6: ...result in damage to the units and other property Principle of a PV plant with this PH50 XXXXT three phase inverter Fig1 1 The inverter may only be operated with a permanent connection to the public po...

Страница 7: ...er to minimize the potential of a shock hazard due to hazardous voltages cover the entire solar array with dark material prior to connecting the array to any equipment Grounding the PV modules The PH5...

Страница 8: ...lectric power company Make sure all covers and doors closed and secure during operation Although designed meeting all safety requirements some parts and surfaces of Inverter are still hot during opera...

Страница 9: ...erter Description Symbol Explanation Inverter status symbol Indicates inverter operation status 6 LED WiFI A C D B E Position Description LED RS 485 F A C B D E F PV Input DC switch AC Output RS 485 W...

Страница 10: ...n the label PV Grid Inverter Model Name DC max voltage MPPT voltage range DC max current AC nominal voltage Grid frequency Rated AC power Max AC out apparent power Max AC current Power factor range Pr...

Страница 11: ...st before installation the inverter system 3 5 Advantage of the inverter Wide input voltage range from 160V 1000Vdc IP65 protection degree Integrated DC switch DSP controller The maximum efficiency is...

Страница 12: ...r Wrench Crimping tools Function To drill holes on the wall Remove PV terminal Strip wire Turn the screw to connect rear panel with inverter To crimp power cables 9 10 Certificate Output terminals 1PC...

Страница 13: ...g and electrical installation should be conducted by a quali ed service personnel Carefully remove the unit from its packaging and inspect for external damage If you nd any imperfections please contac...

Страница 14: ...ich means the inverter can be installed outdoors and indoors The humidity of the installation location should be 0 95 without condensation The installation location must be freely and safely to get at...

Страница 15: ...clearance spaces and make sure there is enough fresh air supply to ensure sufficient cooling of the inverters The inverter can t install to solarization drench firn location We suggest that the inver...

Страница 16: ...0mm 2 Please place the bitmap horizontally on the wall and con rm the level by level 3 Please mark the holes in the 4 mounting holes of the hoe pattern 4 Drill a hole with a depth of 55mm at the mark...

Страница 17: ...an be safely disconnected under load We suggest you choose the AC breaker rating current in this table PH50 9000 12000T PH50 13000 15000T 25A 4000V 32A 400V 5 Electrical connection 5 1 safety warning...

Страница 18: ...g Prepare the pressure screw sealing ring threaded sleeve over the AC cable 3 Insert the stripped and bared conductors L1 L2 L3 N PE into the screw terminals with sign L1 L2 L3 N PE on the socket elem...

Страница 19: ...on the AC terminal with a conductor cross section of at least 10 mm Cu Or install a second protective conductor on the earth terminal with the same cross section as the original protective conductor...

Страница 20: ...nnectors are in paired male and female connectors The connectors for PV arrays and inverters are H4 yunfan connectors Suggestions for the PV modules of the connected strings Same type Same quantity of...

Страница 21: ...ding conductor of the power distribution grid via the ground terminal PE 1 Because of the transformerless design the DC positive pole and DC negative pole of PV arrays are not permitted to be grounded...

Страница 22: ...1 2 RS485 PIN 5 7 RS485 PIN 3 4 6 8 Shielding layer or no connection PIN 1 2 RS485 PIN 5 7 RS485 PIN 3 4 6 8 Shielding layer or no connection 1 8 1 8 1 8 De nitions of RS485 PLUG standard as follows...

Страница 23: ...e type of cable is recommended as STP FTP ASTP information Pull cables outwards to con rm whether they are installed rmly 4 Plug in two terminals Cover the x board 1 8 1 8 1 8 1 8 1 8 1 8 1 8 1 8 2 Sl...

Страница 24: ...ink 8 2 Cleaning the Inverter If the inverter is dirty turn off the AC breaker and DC switch waiting the inverter shut down then clean the enclosure lid the display and the LEDs using only a wet cloth...

Страница 25: ...k if inverter ground properly 3 Check if the DC breaker gets wet 4 If the error message is displayed despite the above checking passed contact the installation contractor or supplier DCI High Output c...

Страница 26: ...n also use an equivalent carton The box must be capable of being closed completely and made to support both the weight and the size of the inverter 10 3 Storing the Inverter Store the inverter in a dr...

Страница 27: ...o weighted efficiency 98 3 97 5 99 5 MPPT efficiency Protection devices DC reverse polarity protection yes Output over current protection yes Output overvoltage protection varistor yes DC reverse pola...

Страница 28: ...ED YES YES Opt YES Standard 5 years 10 years opt CE IEC62109 General Data Features Features 22 11 2 Accessories We offers 5 years product warranty for PH5000 series inverters from date of installation...

Страница 29: ...Breaker Fuse Energy meter 12 PV system installation Installation with multiple inverters on three phase system A Single inverter L1 L2 L3 N PE Fuse L1 L2 L3 N PE L1 L2 L3 N PE Fuse L1 L2 L3 N PE L1 L2...

Страница 30: ...s contact the installation contractor or supplier We need the following information in order to provide you with the necessary assistance Inverter type Inverter error messages Inverter LED display Typ...

Страница 31: ......

Страница 32: ...420 00369 00 PV Grid Inverter...

Отзывы: