Service Manual
PH1800 PLUS 4K/5K
- 9 -
E
B
C
Positioning
Attribute
Reference Value
Failure Status
Q46/Q48/Q41/Q43
Diode
BE:0.6V
BC:0.6V
CE:1V
Short-circuit or burnt
Q15/Q16/Q47/Q49
Diode
BE:0.6V
BC:1.3V
CE:0.2V
Short-circuit or burnt
Q51/Q52/Q54/Q56:120-20035-00(SMD Transistors UTC/2SD1624 2A 50V NPN SOT-89)
Q50/Q53/Q55/Q57:120-20036-00 (SMD Transistors UTC/2SA1020 3A 50V PNP SOT-89)
C
Содержание PH1800 PLUS 4K
Страница 1: ...Service Manual PH1800 PLUS 4K 5K Inverter Charger PH1800 PLUS 4K 5K Service Manual ...
Страница 33: ...Service Manual PH1800 PLUS 4K 5K 31 5 2 2 To pluck AC input and output cable and fan connection cable ...
Страница 36: ...Service Manual PH1800 PLUS 4K 5K 34 Afterwards please Turn ON the unit 6 2 To connect with AC Grid for testing ...