Configuration Sample Flowchart:
Configure Module
(Command 0 x 52)
Configure Inputs
(Command 0 x 53 & 54)
Configure the Counters/Encoder (if using)
(Command 0 x 57)
Save Configuration
(Command 0 x 52)
Check Status Message 1
(Software and Node Status)
Status messages - Status message 1 PGN (EF(Controller Source Address)):
• Status 1 – Factory default configuration returns a value of 1, this should not be on if a module has been configured.
• Status 2 – Configuration Saved returns a value of 1 if the alternate configuration was on (value of 1) and saved the configuration
using “Save Configuration” in Command 52.
• Status 3 – Alternate configuration, a new configuration was made to the module but hasn’t been saved.
• Status 9-14 – Returns a value of 1 each time a Command message 52-57 is sent, to ensure each configuration has been sent.
This is on for a brief moment and then resets.