background image

Technical Data

User manual 9000-41011-0200000_hdb_en_20

 43 / 92

NOTE

A high-energy impulse (surge) applied to the output of the Mico Pro modules 

can cause short-term voltage interruption (max. 3 ms). This protects the con-

nected loads. Mico Pro detects within this time, whether a faulty short circuit 

or a high-energy impulse occurred. If there is no short circuit, Mico Pro will be 

switched on again.

9000-41012-0400000

Tripping current  (I

N

)

Full load per channel 4 A (+20%)

Output current (I

)

Full load all channels 8 A

Power-up delay

Per channel to avoid 

inrush current peaks

75 ms

9000-41012-0600000

Tripping current  (I

N

)

Full load per channel 6 A (+20%)

Output current (I

)

Full load all channels 12 A

Power-up delay

Per channel to avoid 

inrush current peaks

75 ms

9000-41014-0200000

Tripping current  (I

N

)

Full load per channel 2 A (+20%)

Output current (I

)

Full load all channels 8 A

Power-up delay

Per channel to avoid 

inrush current peaks

75 ms

9000-41014-0400000

Tripping current  (I

N

)

Full load per channel 4 A (+20%)

Output current (I

)

Full load all channels 16 A

Power-up delay

Per channel to avoid 

inrush current peaks

75 ms

9000-41014-0600000

Tripping current  (I

N

)

Full load per channel 6 A (+20%)

Output current (I

)

Full load all channels 24 A

Power-up delay

Per channel to avoid 

inrush current peaks

75 ms

Variants Output: Number of channels, Tripping current (I

N

), Output current (I

), 

Power-up delay
Art.-No.

Parameter

Conditions

Value

Characteristics: Disconnecting characteristics | Tripping current (I

N

)

For Mico Pro fix Tripping current (I

N

) 2 A to 10 A

Disconnection time at short circuit: approx. 5 ms

Fig. 4-11: Disconnecting characteristics | Tripping current

Содержание Mico Pro fix 1.10

Страница 1: ...MANUAL Mico Pro Murrelektronik GmbH ...

Страница 2: ...raße 3 71570 Oppenweiler GERMANY Phone 49 7191 47 0 Fax 49 7191 47 491000 info murrelektronik com NOTE Translation of the original instructions Document status Manual number 9000 41011 0200000 Language EN Version 2 0 Date 2019 08 ...

Страница 3: ...lue and 1x red 9000 41000 0000002 Fix Modul Load circuit monitoring with preadjusted tripping current value Designation Art No Mico Pro fix 1 2 9000 41011 0200000 Mico Pro fix 1 4 9000 41011 0400000 Mico Pro fix 1 4 CL2 9000 41011 0400001 Mico Pro fix 1 6 9000 41011 0600000 Mico Pro fix 1 8 9000 41011 0800000 Mico Pro fix 1 10 9000 41011 1000000 Mico Pro fix 1 16 9000 41011 1600000 Mico Pro fix 2 ...

Страница 4: ...international legal regulations 14 3 Description 15 3 1 Product family 15 3 2 Products 16 3 2 1 Mico Pro PS power supply 16 3 2 2 Mico Pro PM power module 16 3 2 3 Mico Pro PD power distribution 16 3 2 4 Mico Pro Plug In link 17 3 2 5 Mico Pro fix 18 3 2 6 Mico Pro flex 19 4 Technical Data 22 4 1 Mico Pro PS Power Supply 22 4 1 1 Electrical data 22 4 1 1 1 Input 22 4 1 1 2 Output 23 4 1 2 Environm...

Страница 5: ...haracteristics 33 4 2 2 1 Climatic 33 4 2 2 2 Mechanical 33 4 2 2 3 Electrical safety 34 4 2 2 4 EMC interference 34 4 2 2 5 EMC immunity 34 4 2 3 Protection 34 4 2 3 1 Device protection 34 4 2 4 Mechanical data 34 4 2 4 1 Materials 34 4 2 4 2 Mounting data 35 4 2 5 Product reliability 35 4 2 6 Conformity Approvals 35 4 3 Mico Pro PD power distribution 36 4 3 1 Electrical data 36 4 3 1 1 Input 36 ...

Страница 6: ...lectrical safety 47 4 5 2 4 EMC interference 47 4 5 2 5 EMC immunity 47 4 5 3 Protection 47 4 5 3 1 Device protection 47 4 5 4 Mechanical data 48 4 5 4 1 Materials 48 4 5 4 2 Mounting data 48 4 5 5 Product reliability 49 4 5 6 Conformity Approvals 49 4 6 Mico Pro fix CL2 module 50 4 6 1 Electrical data 50 4 6 1 1 Input 50 4 6 1 2 Output 50 4 6 1 3 Performance record 52 4 6 2 Environmental characte...

Страница 7: ...3 4 7 5 Product reliability 64 4 7 6 Conformity Approvals 65 5 Mounting 66 5 1 Installation distances 66 5 2 Installation position 67 5 3 Mounting Dismounting 69 6 Installation 72 6 1 Overview 73 6 1 1 Mico Pro PS power supply 73 6 1 2 Mico Pro PM power module 73 6 1 3 Mico Pro PD power distribution 74 6 1 4 Mico Pro fix 74 6 1 5 Mico Pro flex 74 6 2 Terminal 75 6 3 Connecting cable 76 6 3 1 Mico ...

Страница 8: ... 82 7 4 Control and signals 83 7 4 1 Mico Pro PS Mico Pro PM 83 7 4 2 Mico Pro fix 84 7 4 3 Mico Pro flex 84 7 5 Diagnostic 87 7 5 1 Mico Pro PS power supply 87 7 5 2 Mico Pro PM power module 87 7 5 3 Mico Pro fix and flex 88 7 6 Maintenance and cleaning 88 8 Appendix 89 8 1 Components 89 8 2 Accessories 90 8 2 1 Legal notes 90 ...

Страница 9: ...ries CAUTION Low risk danger Failure to observe this warning can lead to mild to moderate injuries NOTICE Possible material damage Failure to observe the warning may cause damage to the device and or the system NOTE Other technical information and notes of Murrelektronik GmbH RECOMMENDATION Notes with this symbol are recommendations of Murrelektronik GmbH PRODUCTS AND ACCESSORIES This symbol indic...

Страница 10: ...ith product related and customer specific software components support ing your application such as diagnostics For any further questions please do not hesitate to contact our sales repre sentatives Customer Service Cen ter CSC Our staff of the Customer Service Center will help you with all questions con cerning installation and start up They support you for example if you have problems with combin...

Страница 11: ... 5 Environmentally friendly disposal Comply with country specific waste disposal regula tions Always dispose of scrap devices in compliance with the valid country specific regulations for waste disposal e g the European Waste Code 16 02 14 Only qualified persons may sort scrap materi als Proceed with caution when dismantling the device since you could injure yourself Sort the separated components ...

Страница 12: ...been contaminated with hazardous substances will not be accepted for repair or disposal Returns Label the product and the packaging with For disposal Package the product Send the package to Murrelektronik GmbH Falkenstraße 3 71570 Oppenweiler GERMANY We will make sure that the items are disposed of in accordance with German legislation The most recent owner is responsible for transport to the retu...

Страница 13: ...ectives which apply to your application or national regulations generally recognized safety rules 2 2 Qualified personnel target group The Mico Pro system may only be mounted put into operation and operated by qualified personnel Personnel is considered qualified if they meet the following requirements The personnel have undergone appropriate technical training Have been trained for the operation ...

Страница 14: ...lek tronik 2 5 Warranty and liability claims Warranty and liability claims shall be lost if the Mico Prosystem is not used according to its designated use damage is caused because the manual and other applicable documents have not been observed see 1 3 2 Applicable documents the personnel was is not qualified 2 6 Legal regulations 2 6 1 National international legal regulations Murrelektronik GmbH ...

Страница 15: ...g current Integrated 0 V wiring concept Enormous space saving Potential distributor for connecting several loads to a Mico Pro channel Cascading of two Mico Pro load circuit monitoring one after the other Channel specific or system integrated control inputs and outputs Mico Pro flex Channel specific switching function via CTRL input Mico Pro flex Quick connection with push in spring clamp terminal...

Страница 16: ...V Voltage range 90 V 265 V Mico Pro power module PM Power feeding module for system supply and control options Designation Article number Function Mico Pro PM 24 V 40 A 9000 41190 0000000 Operating voltage 12 V 24 V Input voltage range 9 V 30 V Total operating current 40 A Control inputs and outputs Mico Pro power distribution module PD Potential distributor Designation Article number Function Mic...

Страница 17: ...nt continuous jumper 40 A Length 500 mm Mico Pro Plug In link 2x red 9000 41000 0000001 2 pieces Farbe red Total operating current continuous jumper 40 A Length 500 mm Mico Pro Plug In link 1x blue and 1x red 9000 41000 0000002 1 piece blue and 1 piece red Color blue and red Total operating current continuous jumper 40 A Length 500 mm Mico Pro Plug In link 1x blue 1x red 250 9000 41000 0000003 1 p...

Страница 18: ...hannels 1 Tripping current 8 A 0 20 Mico Pro fix 1 10 9000 41011 1000000 Number of channels 1 Tripping current 10 A 0 20 Mico Pro fix 1 16 9000 41011 1600000 Number of channels 1 Tripping current 16 A 0 20 Mico Pro fix 2 2 9000 41012 0200000 Number of channels 2 Tripping current 2 A 0 20 Mico Pro fix 2 4 9000 41012 0400000 Number of channels 2 Tripping current 4 A 0 20 Mico Pro fix 2 6 9000 41012 ...

Страница 19: ...8 9 10 A 0 20 Control input and output Mico Pro flex 1 20 9000 41091 1102000 Number of channels 1 Tripping current setting range selectable via button 11 12 13 14 15 16 17 18 19 20 A 5 15 Control input and output Mico Pro flex 2 10 9000 41092 0101000 Number of channels 2 Tripping current setting range selectable for each channel 1 2 3 4 5 6 7 8 9 10 A 0 20 Control inputs and outputs per channel Mi...

Страница 20: ... 10 Mico Pro PM Mico Pro fix 1 2 Mico Pro fix 1 4 Mico Pro fix 1 4 CL2 Mico Pro fix 1 6 Mico Pro fix 1 8 Mico Pro fix 1 10 Mico Pro fix 2 2 Mico Pro fix 2 4 Mico Pro fix 2 6 Mico Pro fix 4 2 Mico Pro fix 4 4 Mico Pro fix 4 4 CL2 Mico Pro fix 4 6 Mico Pro flex 1 10 Mico Pro flex 1 20 Mico Pro flex 2 10 Mico Pro flex 4 10 Mico Pro PD 2x2x06 Mico Pro PD 2x12 DNV GL Location classes Temperature D Humi...

Страница 21: ...21 92 RECOMMENDATION Refer to the appendix for an overview of accessories 8 2 Accessories Storage and transport Avoid mechanical vibrations during transport of the system Mico Pro Adhere to the prescribed climatic conditions see chapter 4 Technical Da ta ...

Страница 22: ... for neutral side 100 240 V Max voltage L or N to PE N A Nominal frequency 50 60 Hz 6 Leakage current N A Variants Input Nominal current Inrush current i2t Efficiency Art No Parameter Conditions Value 9000 41190 0000105 Nominal current 115 V 2 3 A Nominal current 230 V 1 1 A Inrush current 30 A i2t 1 6 A2s Efficiency 115 V 89 4 Efficiency 230 V 90 8 9000 41190 0000110 Nominal current 115 V 3 7 A N...

Страница 23: ...ses 100 load 230 V 16 W Power losses 50 load 115 V 10 W Power losses 50 load 230 V 8 W No load power losses 115 V 1 0 W No load power losses 230 V 1 4 W Power factor 115 V 0 69 Power factor 230 V 0 62 Start up voltage 85 V Fig 4 3 Art No 9000 41190 0000105 Fig 4 4 Art No 9000 41190 0000110 Parameter Conditions Value PFC Passive Internal switching frequency 26 100 kHz Shutdown undervoltage 65 V Shu...

Страница 24: ... Line regulation 5 mV Load regulation 55 mV Ripple Static 15 mV rms Spikes Static 230 mV p p Current 24 V 5 0 A Current 28 V 4 3 A Output power 120 W 9000 41190 0000110 Line regulation 1 mV Load regulation 650 mV Ripple Static 20 mV rms Spikes Static 380 mV p p Current 24 V 10 0 A Current 28 V 8 6 A Output power 240 W Derating 90 109 V 207 W Fig 4 5 Art No 9000 41190 0000105 Fig 4 6 Art No 9000 41...

Страница 25: ...up time 115 V 175 ms Start up time 230 V 200 ms Short circuit current 15 A Output capacitance 5270 µF Return current when switched off 30 mA Parameter Conditions Value Output rise time 17 ms Short circuit energy i2t Infinite A2s Extra current hyper boost No Max switchable capacity on the output Infinite Touch Current 0 1 mA Parameter Conditions Value Operating temperature 25 55 C Operating tempera...

Страница 26: ...e Low voltage power supplies d c output Electromagnetic compatibility EMC EN 61204 3 Emission class B residential commercial and light industry Immunity High severity level Industrial Parameter Conditions Value Radiated emissions EN 55022 CISPR 22 30 1000 MHz Class B Conducted emissions EN 55011 CISPR 11 2009 0 15 30 MHz 0 01 30 MHz Class B Harmonic currents Class A Voltage fluctiation flicker pas...

Страница 27: ...a system the EMC emission values may vary eg due to other ground connections The installer is responsible for the EMC behavior of the entire system Voltage dips and short interruptions EN 61000 4 11 70 10 ms Criterion A 40 100 ms Criterion A 0 5 s Criterion C Parameter Conditions Value ...

Страница 28: ...tion Internal device protection Art No Parameter Conditions Value 9000 41190 0000105 Internal device protection 3 15 A T 9000 41190 0000110 Internal device protection 6 3 A T Current Miniature Circuit Breaker Neozed fuse or equivalent Power Switch A B C D K gG 13 x Iin 2 A 4 A X X 6 A X X X X X 8 A X X X X X X 10 A X X X X X X X 16 A X X X X X X X 20 A X X X X X X X 24 A X X X X X X X 32 A X X X X...

Страница 29: ...ds 35 V autostart Reverse polarity protection No Input Output separation Double or reinforced gal vanic isolation Parameter Conditions Value Parameter Conditions Value Overvoltage protection 36 36 V 600 W 10 1000 us Short circuit protection N A Reverse polarity protection N A Overcurrent protection No Parameter Conditions Value Input output 3000 V Input PE N A Output PE N A Output Alarm 500 V Curr...

Страница 30: ...lue Flame resistance UL 94 V 0 Housing material Plastic Protection class IEC 61140 2 Art No 9000 41190 0000105 Parameter Conditions Value Dimension Depth D 114 mm Dimension Height with unlocking actua tor H 130 mm Dimension Height without unlocking actuator H2 111 mm Dimension Width W 54 mm Net weight 0 41 kg Art No 9000 41190 0000110 Parameter Conditions Value Dimension Depth D 114 mm Dimension H...

Страница 31: ...Ta 40 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 1500000 h 9000 41190 0000110 MTBF 100 load Ta 40 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 800000 h Parameter Conditions Value EMC Directive 2014 30 EU Compliant RoHS 2011 65 EU Compliant REACH No 1907 2006 Compliant LoHS ME list of banned substances Compliant EAC Compliant UL UL 508 UR UL 60950 1 CB Scheme IEC 60950...

Страница 32: ...A CTRL signal Ctrl functions 2 3 are available from software version 1 06a onwards XXXXXX X XX 1 06a 1 OFF high 40 3 ms ON high 20 3 ms 2 OFF high 400 30 ms ON high 200 30 ms 3 OFF high 600 ms ON high CTRL ON 500 ms CTRL switching frequency 10 Hz CTRL overvoltage protection Suppressor diode 36 V Remote switch on ON Possible ON input voltage Low 0 V 5 V high 10 V 30 V ON control current n Number of...

Страница 33: ... trigger current 100 kOhm 1 kOhm Ohmic resistance terminals 90 Input voltage 9 V min 1 channel with output current 90 trigger cur rent 35 Ohm 15 Ohm Adjustable voltage terminals 90 30 V Current at terminal 90 20 mA Symbol Parameter Conditions Value Relative humidity No condensation 5 85 Storage temperature 40 80 C Climate class IEC EN 60721 3 3 3K3 Ta Surrounding airtemperature range 25 55 C Insta...

Страница 34: ...lue Electrostatic discharge housing EN 61000 6 2 EN 61000 4 2 Contact 4 kV air 8 kV High frequency electrical RF fields housing EN 61000 6 2 EN 61000 4 3 80 MHz 1 0 GHz 10 V m Fast transients burst DC inputs and outputs EN 61000 6 2 EN 61000 4 4 2 kV 5 kHz Fast transients burst signal connections EN 61000 6 2 EN 61000 4 4 2 kV 5 kHz Surge voltage DC inputs and outputs EN 61000 6 2 EN 61000 4 5 0 5...

Страница 35: ...nting c 3 5 mm Dimension Mounting d 7 5 mm Net weight 100 g Fig 4 9 Dimensions Parameter Conditions Value MTBF 40 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 4727675 h MTBF 55 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 2954797 h Parameter Conditions Value Product standard EN 61000 6 2 and EN 61000 6 3 Compliant EMC Directive 2014 30 EU Compliant RoHS 2011 65 EU Compl...

Страница 36: ...current Art No Parameter Conditions Value 9000 41000 0000212 Output current I Total 20 A Output current Per clamp U 0 V 20 A 9000 41000 0002206 Output current I Total 2x20 A Output current Per clamp U1 U2 0 V 20 A Symbol Parameter Conditions Value Relative humidity No condensation 5 85 Storage temperature 40 80 C Climate class IEC EN 60721 3 3 3K3 Ta Surrounding airtemperature range 25 55 C Varian...

Страница 37: ...nditions Value Degree of protection EN 60529 IP20 Pollution degree 2 Overvoltage category III Insulation voltage input output Type testing routine check test 50 V Parameter Conditions Value Radio interference field strength housing EN 61000 6 3 Industrial and residu al areas Conducted emission DC inputs and outputs EN 61000 6 3 Industrial and residu al areas Parameter Conditions Value Fast transie...

Страница 38: ...e 36 V Parameter Conditions Value Flame resistance EN 60695 2 1 Low flammability Housing material Plastic Parameter Conditions Value Dimension Depth D 114 mm Dimension Height with unlocking actuator H 130 mm Dimension Height without unlocking actuator H2 111 mm Dimension Width W 0 35 mm are inserted into the adjacent module 24 35 mm Dimension Mounting a 55 5 mm Dimension Mounting b 15 5 mm Dimensi...

Страница 39: ...EN 61000 6 2 and EN 61000 6 3 Compliant EMC Directive 2014 30 EU Compliant RoHS 2011 65 EU Compliant REACH No 1907 2006 Compliant LoHS ME list of banned substances Compliant EAC Compliant UL UL508 NMTR E200364 cUL CSA C22 2 No 14 NMTR7 E200364 UR UL2367 QVRQ2 E321289 CSA CSA C22 2 No 14 CLASS 3211 07 CSAus UL 508 Ed 17 CLASS 3211 87 ...

Страница 40: ...0 C Climate class IEC EN 60721 3 3 3K3 Ta Surrounding airtemperature range 25 55 C Installation height Above sea level without any restrictions 500 m 2000 m Installation height Above sea level max 32 A total operat ing current 2000 m 4000 m Installation height Above sea level max 24 A total operat ing current 4000 m 6000 m Parameter Conditions Value Vibration test IEC 60068 2 6 2007 Test Fc EN 600...

Страница 41: ...0000001 Mico Pro Plug In link 2x red Color Red 9000 41000 0000002 Mico Pro Plug In link 1x blue and 1x red Color Blue red Parameter Conditions Value Dimension Depth D 3 46 mm Dimension Height H 11 4 mm Dimension Width W Width freely dividable 500 mm Net weight Per Mico Pro Plug In link 44 g Parameter Conditions Value Product standard EN 61000 6 2 and EN 61000 6 3 Compliant EMC Directive 2014 30 EU...

Страница 42: ...Number of channels Tripping current IN Output current I Power up delay Art No Parameter Conditions Value 9000 41011 0200000 9000 41011 0400000 9000 41011 0600000 9000 41011 0800000 9000 41011 1000000 9000 41011 1600000 Number of channels 1 9000 41012 0200000 9000 41012 0400000 9000 41012 0600000 Number of channels 2 9000 41014 0200000 9000 41014 0400000 9000 41014 0600000 Number of channels 4 9000...

Страница 43: ...l to avoid inrush current peaks 75 ms 9000 41014 0200000 Tripping current IN Full load per channel 2 A 20 Output current I Full load all channels 8 A Power up delay Per channel to avoid inrush current peaks 75 ms 9000 41014 0400000 Tripping current IN Full load per channel 4 A 20 Output current I Full load all channels 16 A Power up delay Per channel to avoid inrush current peaks 75 ms 9000 41014 ...

Страница 44: ...1 0200000_hdb_en_20 44 92 Characteristics Disconnecting characteristics Tripping current IN For Mico Pro fix Tripping current IN 16 A Disconnection time at short circuit approx 5 ms Fig 4 12 Disconnecting characteristics Tripping current ...

Страница 45: ...41012 0400000 99 3 0 17 V Mico Pro fix 2 6 9000 41012 0600000 99 4 0 15 V Mico Pro fix 4 2 9000 41014 0200000 99 1 0 21 V Mico Pro fix 4 4 9000 41014 0400000 99 4 0 16 V Mico Pro fix 4 6 9000 41014 0600000 99 4 0 15 V Parameter Conditions Value Relative humidity 5 85 Storage temperature 40 80 C Climate class IEC EN 60721 3 3 3K3 Surroundingairtemperature range Ta 25 55 C Variants installation heig...

Страница 46: ...vel max 6 A trigger current full load per channel 4000 m 6000 m 9000 41011 1600000 Above sea level without any restricitons 500 m 4000 m Above sea level max 12 A trigger current full load per channel 4000 m 6000 m Variants installation height Art No Conditions Value Parameter Conditions Value Vibration test IEC 60068 2 6 2007 Test Fc EN 60068 2 6 2008 sin 5 17 8 Hz 1 6 mm 17 8 500 Hz 2 3 g 10x f S...

Страница 47: ...s and outputs EN 61000 6 2 EN 61000 4 5 0 5 kV DM Electrostatic discharge housing EN 61000 6 2 EN 61000 4 2 Contact 4 kV air 8 kV Conducted HF DC connections EN 61000 6 2 EN 61000 4 6 10 VRMS 1 kHz 80 AM sine Conducted HF control terminals EN 61000 6 2 EN 61000 4 6 10 VRMS 1 kHz 80 AM sine High frequency electrical RF fields housing EN 61000 6 2 EN 61000 4 3 80 MHz 1 0 GHz 10 V m Parameter Conditi...

Страница 48: ... Mico Pro fix 4 6 6 A Safety fuse 6 3 A T time lag fuse Safety fuse variants Internal fuse Fail Safe Element per channel Art No Designation Tripping current Fuse Parameter Conditions Value Flame resistance EN 60695 2 1 Low flammability Housing material Plastic Parameter Conditions Value Dimension Depth D 114 mm Dimension Height with unlocking actua tor H 130 mm Dimension Height without unlocking a...

Страница 49: ... Value 9000 41011 0200000 9000 41011 0400000 9000 41011 0600000 9000 41011 0800000 9000 41011 1000000 MTBF 40 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 2430719 h 9000 41011 0200000 9000 41011 0400000 9000 41011 0600000 9000 41011 0800000 9000 41011 1000000 MTBF 55 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 1519199 h Parameter Conditions Value Product standard EN 61...

Страница 50: ...t 0 9 Nominal output voltage Same as input Turn on capacity Until SW 1 01 1 channel depen dent on component tolerance wire length used power supply load current selected current range 20 mF Turn on capacity 1 channel depen dent on component tolerance wire length used power supply load current selected current range 30 mF Variants Output Number of channels Tripping current IN Output current I Power...

Страница 51: ...tage interruption max 3 ms This protects the con nected loads Mico Pro detects within this time whether a faulty short circuit or a high energy impulse occurred If there is no short circuit Mico Pro will be switched on again Characteristics Tripping current For Mico Pro fix 1 4 CL2 4 4 CL2 Fig 4 15 Tripping current for Mico Pro fix 1 4 CL2 and Mico Pro fix 4 4 CL2 ...

Страница 52: ... circuit approx 5 ms Fig 4 16 Disconnecting characteristics Tripping current Article Art No Efficiency Voltage drop per channel Mico Pro fix 1 4 CL2 9000 41011 0400001 96 6 0 06 V Mico Pro fix 4 4 CL2 9000 41014 0400001 96 6 0 06 V Parameter Conditions Value Relative humidity 5 85 Storage temperature 40 80 C Climate class IEC EN 60721 3 3 3K3 Surroundingairtemperature range Ta 25 55 C Variants ins...

Страница 53: ... 17 8 500 Hz 2 3 g 10x f Shock test IEC 60068 2 27 2008 Test Ea EN 60068 2 27 2009 1 2 sin 30 g 11 ms Shocks caused by rough handling Drop test 1 m Parameter Conditions Value Degree of protection EN 60529 IP20 Pollution degree 2 Overvoltage category III Insulation voltage input output Type testing routine check test 50 V Parameter Conditions Value Radio interference field strength housing EN 61000...

Страница 54: ...y electrical RF fields housing EN 61000 6 2 EN 61000 4 3 80 MHz 1 0 GHz 10 V m Parameter Conditions Value Short circuit protection Short circuit proof Overvoltage protection input Suppressor diode 36 V Overvoltage protection output Suppressor diode 36 V Overload protection See Disconnecting charac teristics Voltage monitoring No Safety fuse variants Internal fuse Fail Safe Element per channel Art ...

Страница 55: ...0 41014 0400001 Net weight 108 g Parameter Conditions Value Variants MTBF MTTF Art No Parameter Conditions Value 9000 41011 0400001 MTBF 40 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 2426001 h MTBF 55 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 1076888 h 9000 41014 0400001 MTBF 40 C DIN EN 61709 1999 01 SN 29500 DIN EN ISO 13849 1 2008 12 1516251 h MTBF 55 C DIN EN 6...

Страница 56: ...al 9000 41011 0200000_hdb_en_20 56 92 EAC Compliant UL UL508 NMTR E200364 cUL CSA C22 2 No 14 NMTR7 E200364 UR UL2367 QVRQ2 E321289 CSA CSA C22 2 No 14 CLASS 3211 07 CSAus UL 508 Ed 17 CLASS 3211 87 Parameter Conditions Value ...

Страница 57: ... 30 ms ON high 200 30 ms 3 OFF high 600 ms ON high CTRL ON 500 ms CTRL switching frequency Max 10 Hz CTRL overvoltage protection Suppressor diode 36 V Remote switch on ON Possible ON input voltage Low 0 V 1 V high 9 V 30 V ON control current High 6 mA ON pulse length 0 V and pulse ON high 120 ms ON overvoltage protection Suppressor diode 36 V Parameter Conditions Value Circuit element Static switc...

Страница 58: ...electable for each channel 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 9000 41091 1102000 Number of channels 1 Tripping current IN Full load 20 A 5 15 Tripping current set ting range Selectable for each channel 11 A 12 A 13 A 14 A 15 A 16 A 17 A 18 A 19 A 20 A 9000 41092 0101000 Number of channels 2 Tripping current IN Full load per channel 10 A 20 Output current I Full load all channels 20 A Trippin...

Страница 59: ...ping current IN 1 A to 10 A Disconnection time at short circuit approx 5 ms Fig 4 19 Disconnecting characteristics Tripping current Characteristics Disconnecting characteristics Tripping current IN For Mico Pro flex Tripping current IN 11 A to 20 A Disconnection time at short circuit approx 5 ms Fig 4 20 Disconnecting characteristics Tripping current ...

Страница 60: ... V Mico Pro flex 2 10 9000 41092 0101000 99 6 0 09 V Mico pro flex 4 10 9000 41094 0101000 99 3 0 16 V Parameter Conditions Value Relative humidity 5 85 Storage temperature 40 80 C Climate class IEC EN 60721 3 3 3K3 Variants Installation height Art No Parameter Conditions Value 9000 41091 0101000 9000 41091 1102000 9000 41092 0101000 9000 41094 0101000 Installation height Above sea level without a...

Страница 61: ...000 m 9000 41094 0101000 Installation height Above sea level max 4 A tripping current full load per channel max 55 C Ta 4000 m 6000 m Variants Surrounding air temperature range Ta Art No Designation Parameter Value 9000 41091 0101000 9000 41092 0101000 Mico Pro flex 1 10 Mico Pro flex 2 10 Surrounding air tem perature range Ta 25 55 C 9000 41094 0101000 Mico Pro flex 4 10 Surrounding air tem perat...

Страница 62: ... 17 8 500 Hz 2 3 g 10x f Shock test IEC 60068 2 27 2008 Test Ea EN 60068 2 27 2009 1 2 sin 30 g 11 ms Shocks caused by rough handling Drop test 1 m Parameter Conditions Value Degree of protection EN 60529 IP20 Pollution degree 2 Overvoltage category III Insulation voltage input output Type testing routine check test 50 V Parameter Conditions Value Radio interference field strength housing EN 61000...

Страница 63: ...61000 4 3 80 MHz 1 0 GHz 10 V m Parameter Conditions Value Short circuit protection Short circuit proof Overvoltage protection input Suppressor diode 36 V Overvoltage protection output Suppressor diode 36 V Overload protection See Disconnecting charac teristics Voltage monitoring No Safety fuse variants Internal fuse fail safe element per channel Art No Designation Tripping current Fuse 9000 41091...

Страница 64: ...102000 9000 41092 0101000 Dimension 12 35 mm 9000 41094 0101000 Dimension 24 35 mm Fig 4 22 Dimensions Variants Net weight Art No Parameter Conditions Value 9000 41091 0101000 Net weight 62 g 9000 41091 1102000 Net weight 68 g 9000 41092 0101000 Net weight 82 g 9000 41094 0101000 Net weight 132 g Parameter Conditions Value Variants MTBF MTTF Art No Parameter Conditions Value 9000 41091 0101000 MTB...

Страница 65: ...EN 61000 6 2 and EN 61000 6 3 Compliant EMC Directive 2014 30 EU Compliant RoHS 2011 65 EU Compliant REACH No 1907 2006 Compliant LoHS ME list of banned substances Compliant EAC Compliant UL UL508 NMTR E200364 cUL CSA C22 2 No 14 NMTR7 E200364 UR UL2367 QVRQ2 E321289 CSA CSA C22 2 No 14 CLASS 3211 07 CSAus UL 508 Ed 17 CLASS 3211 87 ...

Страница 66: ...e cooling of the device ensued by natural air circulation The installation location have to be in accordance with the requirements of EN 60950 1 point 4 7 and 4 6 1 Housing protection class IP20 EN 60529 5 1 Installation distances Fig 5 1 Installation distances a 40 mm b 6 mm ...

Страница 67: ...0 9000 41091 1102000 may only be installed in the following positions The device must be installed in the intended position in order to ensure sufficient cool ing and mechanical stability Fig 5 2 Installation position The device must be installed in the intended position in order to ensure sufficient cool ing and mechanical stability Fig 5 3 Installation position for Mico Pro fix 1 16 and Mico Pro...

Страница 68: ...stallation position The Mico Pro PS power supply may only be installed in the following po sition The device must be installed in the intended position in order to ensure sufficient cool ing and mechanical stability Fig 5 4 Installation position for Mico Pro PS 9000 41190 0000105 9000 41190 0000110 ...

Страница 69: ... a DIN mounting rail TH 35 according to EN 60715 The mounting rail must be fastened in a way that it is not twisted during mounting and dismounting Observe the maximum permissible load of the DIN mounting rail ac cording to EN 60715 Fig 5 5 Mounting rails Locking on mounting rail Locking device open Locking device closed ...

Страница 70: ...eft or right side of the previous modules side by side 1 Locking device closed 2 Place the modules parallel to the previous module and insert them uniformly into the mounting rail 3 They snap into place with an audible click and the sys tem s front side is flush 3 Mounting the system cover plates a Cover plate for left side b Cover plate for right side To mount the cover plate 1 Remove the left a ...

Страница 71: ...ion 3 between the cover plates and press it in as far as it will go Dismounting Disconnecting the wiring 1 Insert a slotted screwdriver into position 1 on the mod ule and pull the plug in link continuous jumper out 2 Remove any connected stranded wires from the part to be dismounted To dismount 1 Press the unlocking actuator on the top side of the module or place the slotted screwdriver between th...

Страница 72: ... http shop murrelektronik com associated with the item number PELV All channels can be grounded by connecting any GND 0V terminal to PE Earth Battery operation For battery operation the following conditions must be met Operating voltage of the battery pack 10 V Supply line between the battery and Mico Pro 6 m Use a suitable backup fuse or a short circuit proof battery pack WARNING Risk of fire due...

Страница 73: ...ntrol input 90 23 24 control output Alarm 13 14 control output Fig 6 2 Installation overview 1 24V terminal power input 2 24V bridging contact supply Plug In link continuous jumper for additional system components 3 GND 0V terminal power input 4 GND 0V bridging contact supply Plug In link continuous jumper for additional system components 5 Alarm 13 14 terminals for control output potential free s...

Страница 74: ...erminal 8 U1 U2 0V terminal 9 Internal system connection 10 Unlocking actuator Fig 6 4 Installation overview 1 24V bridging contact supply Plug in link continuous jumper 2 GND 0V bridging contact supply Plug in link continuous jumper 3 OUT terminal for connecting the consumer circuit 4 GND 0V terminal for connecting the consumer circuit 5 Internal system connection 6 Unlocking actuator Fig 6 5 Ins...

Страница 75: ... mit TWIN core end ferrule 0 5 1 0 mm AWG 23 14 12 mm 10 mm Flexible without core end ferrule 0 2 4 0 mm AWG 24 12 10 mm Rigid 0 2 2 5 mm AWG 24 14 10 mm Symbol Conditions Ø Flexible with core end ferrule and plastic collar 0 75 10 mm AWG 19 8 18 mm 18 mm Flexible with core end ferrule 0 75 16 mm AWG 19 6 18 mm 18 mm Flexible mit TWIN core end ferrule 0 75 4 0 mm AWG 19 12 18 mm 18 mm Flexible wit...

Страница 76: ... temperature 40 C 90 ºC with surrounding air temperature 40 C 55 C 6 3 3 Mico Pro fix and flex For Mico Pro fix and flex modules with 1 A to 16 A tripping current NOTE The connection cable at the OUTPUT terminals OUT GND 0V must be ap proved for the following operating temperatures 75 ºC with surrounding air temperature 50 C 90 ºC with surrounding air temperature 50 C 55 C For Mico Pro flex module...

Страница 77: ...hes for increase of power is not per mitted with fix or flex modules NOTE 5 seconds after a shutdown due to overload the consumer circuit channel can be switched on again NOTE Use only in connection with Mico Pro system components NOTE The product may cause audible noise 7 1 Overview 7 1 1 Mico Pro PS power supply Fig 7 1 Operation overview 1 Power LED indication 2 Alarm LED indication 3 ON termin...

Страница 78: ...ico Pro PM power module 7 1 3 Mico Pro PD power distribution Schematic wiring dia gram Fig 7 4 Schematic wiring diagram PD 2x12 Art No 9000 41000 0000212 Fig 7 3 Operation overview 1 Power LED indication 2 Alarm LED indication 3 ON terminal 4 90 23 24 terminals 5 Alarm 13 14 terminals 6 CTRL terminal ...

Страница 79: ...0200000_hdb_en_20 79 92 Fig 7 5 Schematic wiring diagram PD 2x2x06 Art No 9000 41000 0002206 7 1 4 Mico Pro fix Schematic wiring dia gram Fig 7 7 Schematic wiring diagram Fig 7 6 Operation overview 1 ON OFF LED indication ON OFF button ...

Страница 80: ...TRL terminal it can only be reconnected via the CTRL terminal Manually Connect and disconnect by means of the ON OFF button directly on the consumer circuit channel Signals via control inputs On the Mico Pro PM module connect all consumer circuits channels after an overload in the complete system via the ON terminal On the Mico Pro PM module disconnect and connect all consumer cir cuits channels v...

Страница 81: ...rminal Tripping current Set via the Set Iout and ON OFF buttons 1 Switch on the voltage supply of the module 2 Select the desired OUT channel load branch 3 The Set button has to be pressed for 3 s to switch to the tripping cur rent setting mode 4 The OUT channel load branch switches off the LED indication ON OFF lights up red 5 The LED indication 1 10 Iout or 11 20 Iout flashes green 6 Use the Set...

Страница 82: ...ge reset Cascading the expan sion modules NOTE The admissible total current may not be exceeded during cascading Cascading on level 3 L 3 is not allowed Fig 7 10 Cascading Legend PS Power supply unit L Level PM Power module power feeding module 16 A 20 A Fix module or flex module load circuit monitoring with 16 A or 20 A 2 A 10 A Fix module or flex module load circuit monitoring with 2 A to 10 A ...

Страница 83: ...t channel is disconnected manually using the ON OFF button it can only be reconnected manually by means of the ON OFF button If a consumer circuit channel is disconnected via the CTRL terminal it can only be reconnected via the CTRL terminal CTRL signal low 0 V 1 V DC CTRL signal high 9 V 30 V DC 40 3 ms 400 30 ms Consumer circuits channels are disconnected CTRL signal high 9 V 30 V DC 20 3 ms 200...

Страница 84: ...a consumer circuit channel is disconnected manually using the ON OFF button it can only be reconnected manually by means of the ON OFF button If a consumer circuit channel is disconnected via the CTRL terminal it can only be reconnected via the CTRL terminal CTRL signal low 0 V 1 V DC CTRL signal high 9 V 30 V DC 40 3 ms 400 30 ms Consumer circuits channels are disconnected CTRL signal high 9 V 30...

Страница 85: ...Operation User manual 9000 41011 0200000_hdb_en_20 85 92 Fig 7 11 Turn on after short circuit Fig 7 12 CTRL signal variant 1 ...

Страница 86: ...Operation User manual 9000 41011 0200000_hdb_en_20 86 92 Fig 7 13 CTRL signal variant 2 Fig 7 14 CTRL signal variant 3 ...

Страница 87: ... Red Permanently lit Power supply alarm Output voltage too low 21 V LED indication LED state Description Off No error All channels are connected Red Permanently lit At least one channel has been discon nected through overload short circuit or manual switch ing LED display State Description Off Power OFF Green Permanently lit Power ON LED indication LED state Description Off No error All channels a...

Страница 88: ...er supply available on the input side Green Permanently lit Channel connected function OK Green Flashing Channel in the limit range load 90 of the tripping current Orange Permanently lit Channel disconnected via CTRL control input Red Permanently lit Channel disconnected manually via the ON OFF button Red Flashing 1 Hz Channel disconnected overload short circuit Red Rapidly flashing 5 Hz Channel d...

Страница 89: ... 1x red 9000 41000 0000002 Fix Modul Load circuit monitoring with preadjusted tripping current value Designation Art No Mico Pro fix 1 2 9000 41011 0200000 Mico Pro fix 1 4 9000 41011 0400000 Mico Pro fix 1 4 CL2 9000 41011 0400001 Mico Pro fix 1 6 9000 41011 0600000 Mico Pro fix 1 8 9000 41011 0800000 Mico Pro fix 1 10 9000 41011 1000000 Mico Pro fix 1 16 9000 41011 1600000 Mico Pro fix 2 2 9000 ...

Страница 90: ...als Please contact us if you would like to suggest any improvements Copyright It is prohibited to transfer or photocopy the documentation either in paper or in digital form reuse or divulge its contents unless otherwise expressly permitted by Murrelektronik GmbH or in conjunction with the production of documenta tion for third party products that contain products made by Murrelektronik Gm bH Compe...

Страница 91: ...t we have no influence on changes or applications of the technical documentation and even minor changes to the initial product or deviations in the intended applications may render incorrect the specifications contained in the technical documentation For this reason the customer is obliged to label the technical documentation provided by Murrelektronik GmbH if and the extent to which the documenta...

Страница 92: ...ANY 49 7191 47 0 49 7191 47 491 000 info murrelektronik com www murrelektronik com The information in the manual has been compiled with utmost care Liability for the correctness completeness and topicality of the information is restricted to gross negligence ...

Отзывы: