Start-run
timer
CD ignition
To additional
TATTLETALE
®
Additional
CD ignition
7
2
6
5
1
9
3
8
4
Ground
100 ohm, 2 watt
Resistor
(Notes 3 and 4)
10
M5081-C
CD Ignition Models
Magnetic
Switch
Adapter
GND ALT1 ALT2 SW
Terminal Block
NOTE 1:
To CLOSE FUEL VALVE–NOT GROUNDING THE IGNITION (Single CD Ignition Systems) Remove the factory-installed jumper on terminals 6-5.
Do NOT ground terminal 6.
NOTE 3:
To CLOSE FUEL VALVE and GROUND THE IGNITION (Single CD Ignition Systems) Remove the jumper on terminals 6-5.
Connect a 100 ohm, 2 watt resistor between valve terminals 1-2. Ground terminal 6.
NOTE 2:
To CLOSE FUEL VALVE–NOT GROUNDING THE IGNITIONS (Dual CD Ignition Systems) Remove the jumper on terminals 6-5.
Connect second ignition to Magnetic Switch Adapter terminal ALT2.
NOTE 4:
To CLOSE FUEL VALVE and GROUND THE IGNITION (Dual CD Ignition Systems) Remove the jumper on terminals 6-5. Connect a 100 ohm,
2 watt resistor between valve terminals 1-2. Ground terminal 6. Connect second ignition to Magnetic Switch Adapter terminal ALT2.
Jumpers
6
2
3
5
4
1
MS2100
6
2
3
5
4
1
MS2100
TYPICAL WIRING for M5081-C (CD IGNITION MODELS)
Start-run
timer
To additional
TATTLETALE
®
7
2
6
5
1
9
3
8
4
Ground
10
+
--
DC Power
source
M5081-B
Battery Models
Terminal Block
Jumpers
MS2110
IN4005 Diode
for flyback protection
*
*
6
2
3
5
1
4
MS2110
6
2
3
5
1
4
TYPICAL WIRING for M5081-B (BATTERY IGNITION MODELS)
Installation M-7980N page 7 of 12
1-800-548-1191 - http://www.partdeal.com - [email protected]