background image

7

2

6

5

1

9

3

8

4

Valve

Coil

Ground

Jumper

 Optional

Resistor

(See Note)

10

Jumper

Disconnect

Switches

Ignition 1       Ignition 2

7

2

6

5

1

9

3

8

4

Valve

Coil

(Note)

Ground

10

 Switch 2

 Switch 1

White

Black

Red

Ground

Optional
Resistor
(Note)

Internal Wiring
for M2582

M5081 Internal
Wiring

M2582 Internal Wiring

Wiring shown in normal mode of operation (seat open). The 20 AWG
(0.75 mm

2

) wire is color coded to the coil: 

For CD ignitions:

White and Orange

For Magneto ignitions:

White and Green

For Battery: 

White and Blue

Conduit Installation

Install a 1/2 NPT conduit from the M2582 conduit connection to the
power source. See M2582 Dimensions (page 3) for location.

For wiring the M2582 fuel valve to Solid-State TATTLETALE

®

annunciators, refer to pages 9, 10, and 11.

M5081 Internal Wiring

Wiring shown in normal mode of operation (seat open). The 18 AWG 
(1.0 mm

2

) wire is color coded to the coil:

For CD Ignitions: 

White and Orange

For Magneto Ignitions: 

White and Green 

For Battery:

White and Blue

Conduit Installation

Install a 1/2 NPT conduit from the M5081 conduit connection to the
power source. Refer to Dimensions (on page 4) for location.

For typical wiring of the M5081 models refer to pages 7 and 8. 

For wiring the M5081 fuel valves to Solid-State TATTLETALE

®

annunciators, refer to pages 9, 10, and 11.

M5081FS Internal Wiring

For typical Wiring refer to page 8.
For wiring the M5081FS to MARK IV 12/24 refer to page 10.

Magnetic Switch Adapters for Use with
Capacitor Discharge Ignitions

Connect the Magnetic Switch Adapter between the fuel Valve 
terminal 1 and the CD Ignition. See wiring diagrams (pages 7

and 11).

WARNING:

PERFORM THE WIRING OPERATION WITH THE POWER SOURCE “OFF” AND THE AREA MADE NON-HAZARDOUS.

MAKE SURE THE VOLTAGE AND CURRENT REQUIREMENTS ARE WITHIN THE FUEL SHUT-OFF VALVE RATINGS. HARD CONDUIT
WITH APPROVED SEALS IS REQUIRED BY THE NEC FOR HAZARDOUS AREA INSTALLATIONS.  

NOTE

:

For grounding the ignition (CD models only)
through the fuel valve snap-switch, use a
Magnetic Switch Adapter (see 

Magnetic

Switch Adapter

, below) and install a 100

ohm; 2 watt resistor (included on page 11).

NOTE

: For grounding the ignition (CD models only) through the fuel

valve snap-switches, use a Magnetic Switch Adapter, see 

Magnetic

Switch Adapter

, below and the 

“TO CLOSE THE FUEL VALVE and

GROUND THE IGNITION”

attachment, and install a 100 ohm; 2

watt resistor (included with your attachment).

NOTE

: Wiring shown in normal mode of operation (seat open). The 18 AWG (1.0 mm

2

)

wire is red color for both options: 12 VDC and 24 VDC.

WIRING INFORMATION

GND

ALT

 1

SW

+

ALT

 2

IN4007

Negative ground 

Magnetic Switch Adapter shown

65700053 (was 65020126): 

For use with 

negative ground ignitions up to 240 VDC.

65700054 (was 65020127): 

For use with 

positive ground ignitions up to 450 VDC.

65700055 (was 65020155): 

For use with 

negative ground ignitions up to 450 VDC.

White

FV–

FV+

Orange

(IGN)

White

FV–

FV+

Orange

(IGN)

Installation M-7980N page 6 of 12

1-800-548-1191 - http://www.partdeal.com - [email protected]

Содержание M5081FS

Страница 1: ...orward in the line after shut off M5081FS Normally Energized Circuit The M5081FS is manually opened electrically latched open and tripped by interrupting the coil power circuit Magnetic Switch Adapter As ignition systems wear from usage their power output becomes less and less Ignition may not have the capacity to reliably trip the Fuel Valve Therefore the use of a Magnetic Switch Adapter for CD i...

Страница 2: ...3000 84 96 2750 77 88 750 21 24 0 1 0 25 4 2 0 50 8 3 0 76 2 4 0 101 6 5 0 127 0 6 0 152 4 7 0 177 8 8 0 203 2 9 0 228 6 10 0 254 0 4 o z 0 1 1 k g 1 0 o z 0 2 8 k g 5 p s i g 3 4 k P a 0 3 4 b a r 1 0 p s i g 6 9 k P a 0 6 9 b a r 2 0 p s i g 1 3 8 k P a 1 3 8 b a r 3 0 p s i g 2 0 7 k P a 2 0 7 b a r 4 o z 0 1 1 k g 1 0 o z 0 2 8 k g 5 p s i g 3 4 k P a 0 3 4 b a r 1 0 p s i g 6 9 k P a 0 6 9 b ...

Страница 3: ...ed to convert to vacuum control NOTE 2 Thumb operated opening latch 2 5 psi 17 kPa 0 17 bar required to release cocking latch 6 1 8 in 156 mm 1 4 in 6 mm connection control pressure 3 psi 21 kPa 0 21 bar minimum 80 psi 552 kPa 5 52 bar maximum see NOTE 1 Latch Arm see NOTE 2 M2582 M5180 P Magnetic Switch Adapters 65700053 was 65020126 65700054 was 65020127 65700055 was 65020155 M2582 P CAUTION THE...

Страница 4: ...n 366 367 mm 3 4 in 19 mm dia 4 places each end equally spaced on a 15 32 in 121 mm b c bolt circle 45 3 5 8 in 92 mm dia 2 in 51 mm dia 2 places 150 RF raised face pipe flange M5081 and M5081FS M5081 3 Steel Flanged Option CAUTION THE ARROW ON THE SIDE OF THE FUEL VALVE MUST POINT TO THE CORRECT DIRECTION OF THE FLOW FROM FUEL SOURCE TO THE ENGINE APPLY PIPE DOPE ONLY TO FUEL PIPE NOT TO THE FUEL...

Страница 5: ...ow manual opening of the valve The thumb operated latch can be locked in place to hold the lever arm latched The cocking latch will be released when pilot pressure reaches 2 5 psi 17 kPa 0 17 bar M2582 P and M5180 P automatically open at 2 psi 14 kPa 0 14 bar and fully open at 3 psi 21 kPa 0 21 bar See Specifications page 12 for maximum control pressure 3 If vacuum control is desired swap the Cont...

Страница 6: ...K IV 12 24 refer to page 10 Magnetic Switch Adapters for Use with Capacitor Discharge Ignitions Connect the Magnetic Switch Adapter between the fuel Valve terminal 1 and the CD Ignition See wiring diagrams pages 7 and 11 WARNING PERFORM THE WIRING OPERATION WITH THE POWER SOURCE OFF AND THE AREA MADE NON HAZARDOUS MAKE SURE THE VOLTAGE AND CURRENT REQUIREMENTS ARE WITHIN THE FUEL SHUT OFF VALVE RA...

Страница 7: ...NITIONS Dual CD Ignition Systems Remove the jumper on terminals 6 5 Connect second ignition to Magnetic Switch Adapter terminal ALT2 NOTE 4 To CLOSE FUEL VALVE and GROUND THE IGNITION Dual CD Ignition Systems Remove the jumper on terminals 6 5 Connect a 100 ohm 2 watt resistor between valve terminals 1 2 Ground terminal 6 Connect second ignition to Magnetic Switch Adapter terminal ALT2 Jumpers 6 2...

Страница 8: ... 5 Terminal Block NOTE 2 To CLOSE FUEL VALVE NOT GROUNDING THE IGNITIONS Dual Magneto Systems Remove the factory installed jumpers on terminals 6 5 and 9 8 Add 65010065 diode package as shown Do NOT ground terminals NOTE 4 To CLOSE FUEL VALVE and GROUND THE IGNITION Dual Magneto Systems Remove the jumper on terminals 9 8 Add 65010065 diode package as shown Add ground wire to terminal 5 Jumpers 6 2...

Страница 9: ...HE FUEL SHUT OFF VALVE RATINGS HARD CONDUIT WITH APPROVED SEALS IS REQUIRED BY THE NEC FOR HAZARDOUS AREA INSTALLATIONS M5081 C to LCDT PS CD R P positive ground FV GND IGN 1 FV NO C NC Relay Contacts jumper jumper M5081 Terminal block LCDT PS CD R P Terminal block 7 2 6 5 1 9 3 8 4 10 FV FET output rated 0 5 A 250 VDC max Relay contacts rated 3 A 30 VDC 4 A 125 250 VAC M5081 C to LCDT PS CD N neg...

Страница 10: ... MARK IV 12 24 ALM 12 24 FV S D GRD MARK III 12 24 terminal block Auxiliary Relay Auxiliary or Shutdown Relay 7 2 6 5 1 9 3 8 4 10 M5081FS Terminal Block 12 24 VDC Power source MARK III has FET outputs rated 0 5 A 250 V max 1 Auxiliary Relays must be hermetically sealed third party certified for use in Class I Division 2 Gps C D areas 2 1 2 2 K1 K2 IN4005 Diode for flyback protection FV IGN FV ALM...

Страница 11: ...Black Red Magnetic Switch Adapter GND ALT1 ALT2 SW K2 K2 is hermetically sealed auxiliary relay third party certified for use in Class I Div 2 Gps C D areas 1 1 K2 Magnetic Switch Adapter GND ALT1 ALT2 SW jumper jumper M5081 Terminal block 7 2 6 5 1 9 3 8 4 10 K2 is hermetically sealed auxiliary relay third party certified for use in Class I Div 2 Gps C D areas 1 1 SD GRD NA FV ALR MPU GRD 10 32VD...

Страница 12: ...d Seat Kit 55000146 55000131 55000161 55000150 55000155 Top Works Complete Valve Less Body and Vent 55000143 55000132 55000132 65700053 65700053 65010065 65700054 65700054 65700055 65700055 55000143 55000132 Vent Bushing Assembly 55000184 55000153 Diaphragm Assembly 00007908 55050420 Pilot Diaphragm Single Dual ign negative ground up to 240 VDC Single Dual ign positive ground up to 450 VDC Single ...

Отзывы: