background image

HD-96044N page 3 of 4

CAUTION:

PERFORM THE WIRING OPERATION WITH THE POWER SOURCE “OFF”

MAGNETIC PICKUP INSTALLATION

A magnetic pickup is an AC generator. It is normally installed
into the flywheel housing of an internal combustion engine, so
that the starter ring gear acts upon it to generate a voltage pulse
each time a gear tooth passes the end of the sensor. 

Magnetic Pickup Installation 

(

see Figure 5

Drill and tap a hole in the flywheel housing (See 

Specifications

Chart

below for model and thread size).  

IMPORTANT:

Drilling

too deep may damage ring gear teeth. Blow chips with air hose
when drilling and tapping hole. 

Gap Adjustment

Insert magnetic pickup and turn until it stops at the face of the gear.
Back-off the gear by turning the pickup counterclock-
wise 1/4, 1/2, or 3/4 turn (

Figure 4

) .

See 

Gap Chart

(above, right) to determine gap

distance based on the turn. Check gap clear-
ance by rotating the gear completely around. 

NOTE:

Magnetic pickup gap should be 

adjusted so that the minimum voltage required 
is attained at the engine’s lowest RPM. The 
voltage will increase as the speed increases.

If erratic readings occur, remove magnetic
pickup and check the magnetic tip for metal chips.

Murphy Magnetic Pickup Specifications Chart

Pickup Total

Threaded

Thread

Model

Length

Length

Size

MP3298*

3 in. (76 mm)

3 in. (76 mm)

5/8-18 UNF

MP7906

3 in. (76 mm)

3 in. (76 mm)

3/4-16 UNF

MP7905

††

4-1/2 in. (114 mm)

4-1/2 in. (114 mm)

3/4-16 UNF

*

Replaces 20-01-0080 and MP100. Lead wire hookup (12 in. [305 mm]).

Replaces 20-01-0081. Lead wire hookup (12 in. [305 mm]).

††

Replaces 20-01-0082. Lead wire hookup (12 in. [305 mm]). 

Gap Chart

1.

Connect terminal 5 on the HD9063 to engine ground and

connect terminal 4 to battery positive (see Figure 3).

2.

Connect the magnetic pickup cable conductors to terminals 

6 and 7.

3.

If cable is shielded, connect shield to engine chassis ground.

4.

If desired, connect a normally open test push button switch

between terminals 8 and 9.

5.

Connect crank disconnect circuit to crank disconnect termi-

nals 1 thru 3 as discussed in 

Crank Disconnect Relay

Function, 

page 2. On 

HD9063-USOS models

connect the

overspeed circuits 1 thru 3 as discussed in 

Overspeed Relay

and Underspeed Relay Function, 

page 2.

6.

Connect the overspeed circuits to overspeed terminals 10 thru

12 as discussed in 

Overspeed Relay and Underspeed Relay

Function, 

page 2.

WIRING

1 2 3 4 5 6 7 8 9 10 11 12

(+)

(+)

(  )

(  )

K1

K2

12

Common

Common

Normally Open

Normally Open

Normally Closed

Normally Closed

Test

Pushbutton

DC Positive

DC Negative
(Engine Ground)

From Magnetic Pickup

To Engine

Crank Control

Circuit 

or

to Shutdown

Circuits 

(HD9063-USOS) 

To 
Shutdown
Circuits

THREAD

SIZE

5/8-18 UNF

3/4-16 UNF

1/4

1/2

3/4

1

GAP

.013 in. 

.028 in.

.035 in.

.055 in.

(0.33 mm)

(0.71 mm)

(0.88 mm)

(1.39 mm)

.015 in.

.030 in.

.045 in.

.062 in.

(0.38 mm)

(0.76 mm)

(1.14 mm)

(1.57 mm)

TURN

1/4

 

1/2

 

3/4

AC

Meter

After adjusting,
set locknut.

Drill and tap casing
(see thread sizes in 
Specifications).

Casing

Gear (must be made
of magnetic material).

NOTE: Clean gear casing
and magnetic sensor 
of metal chips or filings.

Gap

(see Gap Chart)

Always use a two-conductor shielded cable. Ground the
shield to a metal frame ground at the engine end only.

Never run these wires
next to spark plug wires
or in wire loom with other
wires carrying inductive
loads or alternating current.