MU-M4SOL
User’s Manual
Page 83 of 130
5.3.4.3.1
Run (Generate Data)
The HDBaseT report data collection feature is used to collect the data required to perform HDBaseT
cable analysis.
To access data for HDBaseT cable analysis:
Connect the
MU-M4SOL
test device to both ends of the CATx cable, as shown below in
◼
The HDMI cable
must
be connected to the Internal Generator to ensure that HDMI
traffic is running on the HDBaseT link.
◼
The “local” side of the cable is connected to either the tr
ansmitter or receiver module,
housed in the
MU-M4SOL
chassis.
◼
The “remote” side of the cable is connected to the othe
r
MU-M4SOL
module.
Make sure
that the remote module is terminated by a Pluggable POH Adapter as
shown below.
Figure 101: Cable Test Setup
IMPORTANT
The HDMI cable must be connected to the Internal Generator to ensure that HDMI traffic is running on the
HDBaseT link.
HDBaseT
HDMI