MU-M4SOL
User’s Manual
Page 17 of 130
Figure 12:
MU-M4SOL
Modules Test Setup using Internal Pattern Generator
To setup the system for testing:
Insert the Transmitter or Receiver module into the
MU-M4SOL
main unit in the lower slot
–
this module will be defined as the
local
module. The other module will be defined as the
remote
module.
NOTE
Only the
lower slot
is used to connect modules to the
MU-M4SOL
main unit. The upper slot is used
for module storage only.
2.
Using a CATx cable, connect the HDBaseT port (RJ45) of the local module to the HDBaseT
port of the remote module.
3.
Attach the pluggable PoH adapter to the remote module so that it will function as a PoH
powered device (PD).
Figure 13: Pluggable PoH Adapter on Remote Module
HDBaseT
HDMI
HDMI
Internal Pattern
Generator