background image

 

CLEANING & MAINTENANCE GUIDE:

1.

Motors have lifetime lubrication and do not require scheduled maintenance.

2.

Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it 

will cycle on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air 
hose or brush the condenser fins and cabinet ventilation louvers. In environments where dirt and dust is 
more prevalent, clean more frequently.

3.

Periodically remove fountain top and clean out in-line strainer.

4.

Periodically remove access panel of cooler and clean out inline “Y’’ strainer

For Powder coated units:

 Units should be cleaned using a mild soap solution with a sponge or cotton cloth. 

Wipe down surfaces then rinse with clean water.

For Stainless steel units:

1.

To Remove water spots or rust spots, stainless steel cleaner/polish on a cloth is
recommended.

2. 

If there are stubborn spots or if you wish to treat a scratch, using synthetic abrasive general
purpose pads, such as Scotch-Brite™, are recommended.

3.

Apply stainless steel cleaner/ polish to the synthetic abrasive pads and carefully rub the 
panel with the grain.

4. 

DO NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will
void the Murdock warranty. DO NOT use abrasives on powder coated units.

5. 

Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/ 

polish is maintained, stainless steel surfaces will retain their new, clean, polished 
appearance indefinitely.

DRINKING FOUNTAIN CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE 

Note: Use the universal maintenance tool to perform the following:

1. 

Strainer plug must be removed before cartridge replacement and strainer maintenance (no need to turn the 
water off at the angle stop). Some residual water will drain during plug removal.

2. 

Clean strainer as needed using clean water.

3. 

Cartridge replacement - insert diamond end of the universal tool into pushbutton, rotate 90 degrees and pull 
firmly to remove the button. Remove cartridge retaining nut . Remove and replace cartridge. When replacing 
cartridge be sure to align the inlet and outlet ports on the cartridge with the ports in the valve body.

NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

ITEM #

PART NUMBER DESCRIPTION

1

7000-050-001

Valve Cartridge Assembly

2

7000-060-000

Valve Cartridge

3

7000-053-199

Jam Nut

2

1

3

CARTRIDGE VALVE PARTS BREAKDOWN

 

M-OBR4-GRD

Page 14 of 17

New: 12

/01/17

7020-960-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

 OUTDOOR BOTTLE FILLERS

 

Содержание M-OBR4-GRD Series

Страница 1: ...rges and does not apply to materials which have been damaged by other causes such as mishandling improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the...

Страница 2: ...ovide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S M OBR4 GRD Page 2 of 17 New 12 01 17 7020 960 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phon...

Страница 3: ...rain well See rough in details 5 Completely flush water supply lines of all foreign debris before connecting to the fixture DRINKING FOUNTAIN START UP 1 Before connecting power supply but after thoroughly flushing the supply line and connecting it to the cooler turn on building water supply and check all connections for leaks 2 Air within the drinking fountain system or the structure supply piping...

Страница 4: ... 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of OUTDOOR BOTTLE FILLERS 1 1 4 O D Drinking Fountain Waste 1 1 4 O D Bottle Filler Drinking Fountain Waste 1 2 1 Provide wall opening as indicated in rough in detail provided Block out for bottle filler box and provide structural support for mounting pl...

Страница 5: ...te 2x6 Stud Frame Finish Wall Ref only 1 2 3 2 Separate Fixture Panel Bottle Filler Box Mounting Plate and 10 32 x 1 4 Screws from packaging careful to avoid damage to fixtures and fixture sub assemblies 5 Anchoring Hardware 4 4 1 2 3 Finished Floor 36 267 8 1 281 2 3 Supporting Mounting Plate against wall align Bottle Filler opening and Mounting Plate Ø1 4 Anchoring holes with structural support ...

Страница 6: ...g Plate opening and secure with 10 32 x 1 4 Phillips Head Screws Note Cutoff 2 1 2 of material from the tailpiece See Detail A 2 Position Bottle Filler Panel and center to Mounting Plate and secure with 10 32 x 1 2 Stainless Steel Flat Head Center Reject Hex Screw 3 With Bottle Filler Panel installed to open Bottle Filler remove 10 32 x 3 4 Flat Head Center Reject Screws and swing open Bottle Fill...

Страница 7: ... studs through the Bottle Filler Panel and into the Mounting Plate so that a minimum of 1 1 4 of thread projects beyond Bottle Filler Panel 3 Align threaded studs with drinking fountain mounting openings and slide fixtures to panel and secure with nuts and washers 2 Remove the Drinking Fountain bottom Access Panel by removing the Access Panel Vandal Resistant Screws Be sure to safeguard drain Acce...

Страница 8: ...s are required from the Building Water Supply Line to connect to 2 1 4 NCT x 1 4 OD Push In Y Strainers and 1 4 NPT Male Fitting for the Bottle Filler Supply Line See Steps 3 and 4 DO NOT SOLDER Soldering will damage strainer O Ring preventing a watertight seal Layout shown for reference only To Building Water Supply Line 3 8 OD Push in Tee Ref Only 3 6 1 4 NCT x 1 4 OD Push In Y Strainer 7 1 4 OD...

Страница 9: ...he Drinking Fountains To increase or decrease flow use slotted screwdriver Re install Access Panel with screws 4 Connect the last Multiple Water Supply Connection to the 1 4 OD Tube x 1 4 NPT Male Fitting Note An adapter is required to connect the Main Water Supply Line to the 1 4 Male NPT Fitting Connect the blue 1 4 OD Tube to Bottle Filler Spout 1 4 NCT x 1 4 OD Drinking Fountain 1 2 Drinking F...

Страница 10: ...ber of OUTDOOR BOTTLE FILLERS 1 1 4 Tee Assembly with 1 1 Remove the 1 1 4 Tee Assemblies with compressions and the 1 1 4 OD x 4 Long Brass Tubing from packaging 2 From the interior of the building install Tee Assembly with Compression to Drinking Fountain and Bottle Filler Cut to fit Drinking Fountain tailpiece 1 1 4 OD x 4 Long 2 21 4 1 1 2 Slip Joint Compression Nuts 1 1 4 OD Bottle Filler Tail...

Страница 11: ...855 4860 www murdockmfg com Member of OUTDOOR BOTTLE FILLERS 3 4 Install P Traps to Waste outlets P Traps are provided by others P Trap by others 1 2 1 1 4 OD Waste Outlet Tailpiece Bottle Filler 3 From the interior of the building of the fixture wall install Tee Assembly with Compression to Drinking Fountain with Two tailpieces Cut to fit Drinking Fountain tailpiece 21 4 1 1 4 OD Vent Outlet Tail...

Страница 12: ...counterclockwise to remove 3 Remove and replace the cartridge turning clockwise to secure 4 Turn Shut Off Valve Knob a 1 4 turn counterclockwise to open water supply 5 Test for leaks and proper operation before closing Bottle Filler Access Door and re fastening 10 32 Screws Water Filter Cartridge Replacement Instructions M OBR4 GRD Page 12 of 17 New 12 01 17 7020 960 001 MURDOCK MFG 15125 Proctor ...

Страница 13: ...n solenoid valve outlet elbow clogged remove clean h No power to transformer connections loose or wires cut 3 WATER DRIPS OR WILL NOT SHUT OFF a Open fixture Loosen nuts holding valve bracket assembly to bottom of fixture but do not remove Move complete valve bracket assembly further back from the front push pad and tighten to lock in place b Replace valve cartridge SENSOR TROUBLE SHOOTING 4 IF LI...

Страница 14: ... coated units 5 Stainless steel should be kept clean at all times If a coating of stainless steel cleaner polish is maintained stainless steel surfaces will retain their new clean polished appearance indefinitely DRINKING FOUNTAIN CARTRIDGE REPLACEMENT STRAINER MAINTENANCE Note Use the universal maintenance tool to perform the following 1 Strainer plug must be removed before cartridge replacement ...

Страница 15: ...iner 2 7000 068 001 Retaining Ring and Button Assembly 8 0112 002 000 Center Reject Allen Button Head Screw 3 7000 065 001 Recessed Pushbutton Valve Assembly 9 0296 025 199 Center Reject Hex Driver Bit 4 7000 012 001 Stainless Steel Bubbler 10 0401 128 000 128 O Ring 5 0152 010 000 Center Reject Allen Flat Head Screw 11 7000 017 001 Elbow O Ring x 1 1 4 Compression 6 7000 006 000 Flat Drain Adapte...

Страница 16: ...LL MOUNTED DRINKING FOUNTAIN 6 0116 004 000 10 32 x 1 4 ROUND HEAD SCREW 2 JSMBF505 001 COVER PLATE ASSEMBLY 7 JSMBF494 001 WATER AND AIR SUPPLY COMPONENTS 3 0152 002 000 10 32 x 1 2 FLAT HEAD SCREW 8 JSMBF504 001 WASTE OUTLET COMPONENTS 4 JSMBF475 001 BOTTLE FILLER DOOR ASSEMBLY 9 JSMBF501 001 MOUNTING PLATE ASSEMBLY 5 JSMBF462 002 BOTTLE FILLER HOUSING ASSEMBLY 1 1 4 5 9 2 3 8 7 6 M OBR4 GRD Ser...

Страница 17: ...AD SCREW 3 JSMBF479 199 BOTTOM SCREEN 4 JSMBF480 199 ALCOVE SCREEN PLATE 5 0302 005 000 1 4 20 UNC STN STL HEX NUT 6 2566 050 002 BACK OUTLET PUSHBUTTON ASSY 7 2566 022 000 ESCUTCHEON RETAINER 8 2566 001 000 AIR TROL DIAPHRAGM 9 2566 056 199 DIAPHRAGM RETAINER BACK OUTLET 10 1895 450 000 1 8 OD NYLON COMPRESSION NUT 11 7013 010 199 NANO SENSOR BRACKET 12 6527 108 000 8 INTERNAL TOOTH LOCKWASHER 13...

Отзывы: