CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE
Note: Use the -VR maintenance tool to perform the following:
1. Strainer plug 4 must be removed before Cartridge replacement and Strainer
maintenance (no need to turn the water off at the Angle Stop). Some residual water will drain
during Plug removal.
2. Clean Strainer 4 as needed using clean water.
3. Cartridge replacement - Rotate and remove -VR Pushbutton Escutcheon 6 to release Pushbutton 7 and Springs 8 9 to
access Cartridge.
4. Remove Cartridge Retaining Nut 10 . Remove and replace Cartridge 2 . When replacing Cartridge be sure to align the
Inlet and Outlet Ports on the Cartridge with the Ports in the Valve Body.
5. Install item 10 using Maintenance Tool 5 (Becareful not to over tighten)
6. Install Button Assembly items 6 7 8 9 using Maintenance Tool 5 . Insure Springs are installed in Button correctly.
7. Reinstall Strainer 4 and Plug 3 using Maintenance Tool 5 .
NOTE: STRAINER FILTER SCREEN
MUST BE IN PLACE FOR
WATER TO FLOW.
ITEM
PART NUMBER
DESCRIPTION
1
7003-095-001
VALVE ASSEMBLY
2
7000-060-000
FLOW REGULATOR CARTRIDGE(0.5 GPM)
3
7003-097-001
O-RING &STRAINER PLUG
4
7003-864-000
STRAINER FILTER SCREEN
5
7003-194-199
(-VR) MAINTENANCE TOOL
6
7003-197-199
(-VR) PUSHBUTTON ESCUTCHEON, CHROME
7
7003-196-199
(-VR) PUSHBUTTON, CHROME
8
7003-195-000
(-VR) PUSHBUTTON OVERTRAVEL SPRING
9
7003-193-000
(-VR) PUSHBUTTON RETURN SPRING
10
7000-052-000
RETAINING NUT
2
4
3
1
5
5
6
7
8
9
10
A172VR
Page 7 of 10
Revised:
12/22/17
7020-917-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAIN