START UP:
1. Before connecting Power Supply and assembling Bottom Cover to Drinking Fountain, but after thoroughly flushing the
supply line and connecting it to the fixture, turn on building water supply and check all connections for leaks.
2. Air within the Drinking Fountain system or the structure supply piping will cause an irregular Bubbler outlet stream until
purged out by incoming water. Covering the Bubbler with a clean cup (or similar object) is recommended when first
activating Drinking Fountain to prevent excessive splashing. Depress the Pushbutton until steady water stream is
achieved.
3. If water flow requires adjustment, insert a Slotted Narrow Blade Screwdriver through the hole centered on the Pushbutton
to the flow regulator. Turning clockwise will increase flow and turning counterclockwise will decrease flow.
4. Recheck all water and drain connections with water flowing through system.
5. Assemble Bottom Cover to Drinking Fountain with Screws furnished.
A172VR
Page 5 of 10
Revised:
12/22/17
7020-917-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
OUTDOOR INSTALLATION INSTRUCTIONS:
1. Caulk all around the Basins where it contacts the wall and where Aprons contact the wall as shown, to prevent rain water
from leaking into the Cabinet.
DO NOT CAULK THE REMOVABLE ACCESS COVER.
Add 1/4” thick piece of soft Rubber
Weather Strip (provided by installer) between the units as shown.
STANDARD CONFIGURATION
ALTERNATIVE CONFIGURATION
CAULKING
WEATHER STRIP
WEATHER STRIP
(BETWEEN UPPER
AND LOWER UNITS)
CAULKING
WEATHER STRIP
(BETWEEN UPPER
AND LOWER UNITS)
CAULKING
WEATHER STRIP
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAIN