A172UBL-VR SERIES REFRIGERATED BI-LEVEL WALL MOUNTED WATER COOLER
Note: Alternate Mounting. There are no mounting changes to be made for -SO models.
IMPORTANT:
1. Waste P-Trap, Water Supply Service Angle Stop Valve and 2” x 4” Electrical Plug-In Receptacle to be supplied by others in
accordance with local codes. A Metallic P-Trap (by others) must be used for the drain connection.
2. Provide 4” minimum clear space on fixture sides to allow for proper ventilation through Cabinet Louvers.
3. Water supply is 3/8” Outside Diameter Copper Tube. Waste is 1-1/4” Outside Diameter.
4. Completely flush supply lines of all foreign debris before connecting to fixture. Drinking Fountain designed to not affect taste,
odor, color, or sediment. Optional water filter (WF1) is available should any of these problems arise from the water supply.
5. If possible, limit exposure of the Drinking Fountain to direct sun light. The actual surface temperature of a Drinking Fountain in
direct sunlight on a 90°F day, the Drinking Fountain would be about 140°F.
6. Do NOT solder Copper Tube when inserted into the Coupler as damage to the O-Ring will result.
7. All burrs must be removed from outside of cut Tubes before inserting into Coupler or other components.
9.
Warranty is voided
if installation is not made following current Murdock Mfg. installation instructions and if components are
assembled to the fixture that is not approved by Murdock Mfg.
10. Fixture operates within water pressure range of 20 to 105 PSIG (138 to 724 kPa). Murdock Mfg. will not warranty fixtures
damaged when connected to supply lines with flow pressure lower than 20 PSIG (138 kPa) or higher than 105 PSIG (724
kPa). A pressure regulator must be furnished by others on supply line if inlet pressure is greater than 105 PSIG (724 kPa).
11.
Per UPC 609.10
-
All building water supply systems in which quick acting valves are installed shall be provided with devices to
absorb the hammer caused by high pressure resulting from the quick closing of the valve. These pressure-absorbing devices
shall be approved mechanical devices. Water pressure-absorbing devices will be installed as close as possible to the quick
closing valve.
A172VR
Page 3 of 10
Revised:
12/22/17
7020-917-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
1-1/4" [32]
P-TRAP BY
OTHERS
1
3
8
"
[35]
6"
[152]
12"
[305]
*33"
[838]
6"
[152]
A. 3/8" NCT SUPPLY INLET
B. WASTE OUTLET FOR 1-1/4"
P-TRAP BY OTHERS.
C. Ø3/8" HANGER BRACKET PUNCHING, 3 PLACES
FOR ANCHORING HARDWARE BY OTHERS.
D. Ø1/4" PUNCHING, 2 PLACES FOR ANCHORING
HARDWARE BY OTHERS.
E. CAULK FOR OUTDOOR UNITS
(SEE PAGE 5)
F. Electrical Service Rough(If Bottle
Filler is being used)
E
B
A
E
21
7
8
"
[556]
35
1
4
"
[896]
C
18
5
8
"
[472]
D
19
3
8
"
[491]
6"
[152]
13
3
8
"
[340]
7
7
8
"
[202]
4
1
4
"
[108]
2
1
4
"
[57]
7
7
8
"
[202]
6
5
8
"
[169]
6
5
8
"
[169]
5
1
4
"
[133]
16
5
8
"
[422]
F
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAIN