No
Item
Test Method
13 Temperature
Appearance
No marking defects.
Fix the capacitor to the supporting jig in the same manner and under
Sudden
the same conditions as (10). Perform the five cycles according to the
Change
Capacitance
Within ±12.5%
four heat treatments listed in the following table. Let sit for 24±2
Change
hours at room temperature, then measure.
D.F.
0.120max.
I.R.
50Ω
・
F min.
Dielectric
No failure
Strength
・
Initial measurement
Perform a heat treatment at 150+0/-10°C for one houg and then let sit
for 24±2 hours at room temperature.
Perform the initial measurement.
14 High
Appearance
No marking defects.
Apply the rated voltage at 40±2
℃
and 90 to 95% humidity for 500±12 hours.
Temperature
The charge/discharge current is less than 50mA.
High
Capacitance
Within ±12.5%
Humidity
Change
・
Initial measurement
(Steady State)
Perform a heat treatment at 150+0/-10°C for one houg and then let sit
D.F.
0.2 max.
for 24±2 hours at room temperature.
Perform the initial measurement.
I.R.
12.5Ω
・
F min.
・
Measurement after test
Perform a heat treatment at 150+0/-10
℃
for one houg and
then let sit for 24±2 hours at room temperature, then measure.
15 Durability
Appearance
No marking defects.
Apply 150% of the rated voltage for 1000±12 hours at the
maximum operating temperature ±3
℃
. Let sit for 24±2 hours at
Capacitance
Within ±12.5%
room temperature,then measure.
Change
The charge/discharge current is less than 50mA.
・
Initial measurement
D.F.
0.2 max.
Perform a heat treatment at 150+0/-10
℃
for one houg and then let sit
for 24±2 hours at room temperature.
Perform the initial measurement.
I.R.
25Ω
・
F min.
・
Measurement after test
Perform a heat treatment at 150+0/-10
℃
for one houg and
then let sit for 24±2 hours at room temperature, then measure.
■
SPECIFICATIONS AND TEST METHODS
Specification
Step
1
2
3
4
Temp.(
℃
)
Min.
Operating
Temp.
+
0/-3
Room
Temp.
Max.
Operating
Temp.+3/-0
Room
Temp.
Time(min.)
30
±
3
2 to 3
30
±
3
2 to 3
JEMCAS-00669A
3