background image

© Munters AB, 2014

24

Spare part list

Chapter9

TU600STD

1

2

3

5

4

6

7

8

9

10

11

12

13

17

16

14

6

20

21

15

16

19

18

15

Содержание TU600

Страница 1: ...Manual for use and maintenance TU600 TU800 Chimney fan TU Ag MIT UmGB 2181 04 14 rev 1 0 CE Declaration of conformity ...

Страница 2: ...ive 2006 42 EC paragraph A Annex II and to ErP Directive 2009 125 CE Commission Regulation 327 2011 This document is destined for the user of the apparatus it may not be reproduced in whole or in part committed to computer memory as a file or delivered to third parties without the prior authorisation of the assembler of the system Munters A S reserves the right to effect modifications to the appar...

Страница 3: ... 2 Points to observe 7 3 BEFORE USING 8 3 1 Delivery check 8 3 2 Packaging and transport of assembled fans 8 3 3 Structure 8 4 Operating Conditions 9 5 INSTALLATION 10 5 1 Electrical connections for standard motor 10 5 2 Electrical connections for Munters Drive motor 10 5 3 Assembly instructions 11 5 4 Placement of fans 13 5 5 Electrical wiring 14 6 COMMISSIONING 17 Index ...

Страница 4: ...NICAL DATA 18 7 1 Dimensions 18 7 2 Technical specification 19 7 3 Motor specifications 20 7 4 Data for Fan Eco Design Directive 20 8 MAINTENANCE 21 8 1 Introduction 21 8 2 Cleaning 21 9 SPARE PART LIST 22 10 WARRANTY 30 Index ...

Страница 5: ...ned for moving air to control temperature and humidity in livestock Model Tu600 TU800 Year of manufacture 2014 conforms with the essentiAl safety requirements stated by Apparatus Directive 2006 42 EC and performance requirements comply with the eRp directive 2009 125 ce With particular reference to the following provisions UNI EN 953 2009 UNI EN ISO 12100 2010 UNI EN ISO 12499 2009 UNI EN ISO 1385...

Страница 6: ...y fan In order to realize the full benefit from this product it is important that it is installed commissioned and operated correctly Before installation or using the fan this manual should be studied carefully It is also recommended that it is kept safely for future reference The manual is intended as a reference for installation commissioning and day to day operation of the fans 1 3 Notes Date o...

Страница 7: ... into the atmosphere must be within the limits determined by local authorities the fan is intended to be installed and used by qualified personnel who are familiar with relevant safety requirements safety equipment necessary for the prevention of accidents at the mounting and operating site shall be provided by the buyer in accordance with the regulations prevailing in the local country fans shoul...

Страница 8: ...ould not be done manually as the fans have no handles or grips Consequently one of the following alternatives should be used forklift before loading make sure that forks are adequately protected for avoiding to damage fan parts crane fix adequate supports on the housing and then hook the lifting cable on them 3 3 Structure The fans consist of the following components fan housing in plastic with st...

Страница 9: ...tructure which helps to keep under control temperature in livestock buildings Normal ambient temperature limits are 25 C to 50 C Maximum altitude is 1000m above sea level Should a fan be required to operate at a higher altitude the loss in mass flow heat removing capacity due to lower air density should be taken into consideration Operating conditions 4 ...

Страница 10: ... ac fig 2 With frequency inverter 3x400v ac 5 2 Electrical connections for Munters Drive motor fig 3 1 Cover of controller housing 2 3 cable glands 3 x M16 included 3 cable entry points with plastic fastener 4 mains connection 5 connection alarm relay 6 connection controls 7 slot for add on module Installation 5 ...

Страница 11: ...3 Assembly instructions fig 4 Click the two rolling junctions together as in the zoom showing the cut of the pipe Installation Chapter5 Temperatures up to 85 C can be present on the controller housing to connect always use heat resistant wires or as an alternative silicon tubes self tapping screws are used for the PE conductor connection these cannot be loosened and sufficiently retightened infini...

Страница 12: ...t pipe into the sleeve and fasten with 8 pcs of sheet metal screws 4 8x16 N136 121 and washers 5 3x15 stainless 02 420 fig 6 Assembled pipes fig 7 Mount 3 pcs motor fittings inside the pipe in rough bored holes Figure illustrates motor suspension and cut of the pipe fig 8 Fasten the fan on the shaft Mount the flange on the motor with 4 set screw 6x16 Installation Chapter5 ...

Страница 13: ... Munters AB 2014 13 5 4 Placement of fans Roof installation fig 9 Ceiling installation fig 10 Floor inside installation fig 11 Installation Chapter5 ...

Страница 14: ... reasons the overload switch can be locked by a padlock not supplied by Munters The installer must provide a suitable control box in compliance with requirements specified by EN 60204 rules Electrical earthing must be carried out according to local regulations before the motor is connected to the supply voltage Installation Chapter5 In order to comply with CE regulations fans must be mounted so th...

Страница 15: ...g the fan to the mains electrical supply These diagrams are however subject to local laws and regulations and should be modified if necessary to comply with such laws and regulations fig 15 fig 16 Overload protection switch Circuit breaker Fan motor Installation Chapter5 1 2 3 ...

Страница 16: ...n be ordered from Munters and be supplied with the fans NOTE Motor specifications are written on the label stuck on the motor Before operating the fan make sure the motor turns in a way to move the air from bell mount towards outside of the building To change the direction of rotation of a three phase motor it is necessary to change the connection of two of the phases Warning The connection cable ...

Страница 17: ...the building 5 remove all obstacles from the front and back sides of the fans 6 ensure that all people and animals are standing clear of the fans 7 turn the electrical power to the fans on 8 observe the direction in which the propeller of each of the fans are turning to ensure that it is in the same direction 9 turn the electrical power to the fans off Commissioning 6 Do not attempt to correct any...

Страница 18: ...Model A B C D E F G H TU600 1 830 633 900 900 660 1 000 170 TU800 1 830 837 1 100 1 100 660 1 000 170 floor inside outside dimensions fig 19 Model A B C D E F G H TU600 3 830 633 900 900 660 1 000 170 940 TU800 3 830 837 1 100 1 100 660 1 000 170 940 Technical data 7 ...

Страница 19: ...765 18 329 10 788 19 364 11 397 8 741 5 145 Airflow at 40 Pa m 3 h cfm 9 560 5 627 11 414 6 718 15 460 9 099 16 730 9 847 16 728 9 846 18 244 10 738 3 881 2 284 Specific performance at 0 Pa m 3 h W cfm W 27 5 16 2 28 4 16 7 91 4 53 8 31 7 18 6 33 0 19 4 25 0 14 7 34 0 20 0 116 0 68 3 Specific performance at 20 Pa m 3 h W cfm W 24 0 14 1 24 9 14 7 57 2 33 7 27 0 15 9 27 0 15 9 22 0 12 9 27 8 16 4 6...

Страница 20: ...t category Efficiency category Efficiency grade Target efficiency grade 2013 2015 VSD must be installed with the fan Motor power input at optimum energy efficiency W Flow rate at optimum energy efficiency m 3 h Pressure at optimum energy efficiency Pa RPM at optimum energy efficiency Specific ratio TU600 STD 250W 27 5 A static 36 36 no 485 8 150 58 9 898 1 TU600 Munters Drive 660W 41 1 A static 49...

Страница 21: ...Maintenance 8 The capacitor in single phase motors can retain a charge which appears across the motor terminals even when the motor has reached standstill Warning Keep motor body clean Dust deposit on motor body will lead to overheating and failure of bearings and motor itself Do not use water for motor cleaning Use compressed air only Water spraying will cause rust inside the bearings and lead to...

Страница 22: ... Munters AB 2014 22 TU600 Munters drive 1 2 3 5 4 6 7 8 9 10 11 12 13 17 16 14 6 20 21 15 16 19 18 15 Spare part list 9 ...

Страница 23: ...ive motor cage Ø600 1 8 hexagon screw M6x16 11 9 propeller Ø600 1 10 washer Ø5x20 1 11 spring washer Ø5 1 12 hexagon screw M5x16 1 13 fan body Ø600 1 14 bush for damper shaft 2 15 washer Ø6 18 8 16 self locking nut M6 8 17 axLE 1 18 damper Ø600 1 19 ACTUATOR SHAFT 1 20 AIR CONVEYOR Ø600 1 21 Slotted pan head screw M6 16 4 table 3 propeller motor group motor propeller poWER W RPM PHASES tension V B...

Страница 24: ... Munters AB 2014 24 Spare part list Chapter9 TU600STD 1 2 3 5 4 6 7 8 9 10 11 12 13 17 16 14 6 20 21 15 16 19 18 15 ...

Страница 25: ... 1 8 hexagon screw M6x16 11 9 propeller Ø600 1 10 washer Ø5x20 1 11 spring washer Ø5 1 12 hexagon screw M5x16 1 13 fan body Ø600 1 14 bush for damper shaft 2 15 washer Ø6 18 8 16 self locking nut M6 8 17 axLE 1 18 damper Ø600 1 19 ACTUATOR SHAFT 1 20 AIR CONVEYOR Ø600 1 21 Slotted pan head screw M6 16 4 table 3 propeller motor group motor propeller poWER W RPM PHASES tension V BLADES No inclinaTIO...

Страница 26: ... Munters AB 2014 26 1 2 3 4 5 6 7 8 9 10 11 12 13 17 16 14 6 20 21 15 16 19 18 15 26 TU800 Munters drive Spare part list Chapter9 ...

Страница 27: ...ive motor cage Ø800 1 8 hexagon screw M6x16 12 9 propeller Ø800 1 10 washer Ø5x20 1 11 spring washer Ø5 1 12 hexagon screw M5x16 1 13 fan body Ø800 1 14 bush for damper shaft 2 15 washer Ø6 18 8 16 self locking nut M6 8 17 axLE 1 18 damper Ø800 1 19 ACTUATOR SHAFT 1 20 AIR CONVEYOR Ø800 1 21 Slotted pan head screw M6 16 4 table 1 propeller motor group motor propeller poWER W RPM PHASES tension V B...

Страница 28: ... Munters AB 2014 28 1 2 3 4 5 6 7 8 9 10 11 12 13 17 16 14 6 20 21 15 16 19 18 15 Spare part list Chapter9 TU800STD ...

Страница 29: ... M6x16 12 9 propeller Ø800 1 10 washer Ø5x20 1 11 spring washer Ø5 1 12 hexagon screw M5x16 1 13 fan body Ø800 1 14 bush for damper shaft 2 15 washer Ø6 18 8 16 self locking nut M6 8 17 axLE 1 18 damper Ø800 1 19 ACTUATOR SHAFT 1 20 AIR CONVEYOR Ø800 1 21 Slotted pan head screw M6 16 4 table 2 propeller motor group motor propeller poWER W RPM PHASES tension V BLADES No inclinaTION 370 900 1 230 5 ...

Страница 30: ...iscovery of the defect and within 12 months of the delivery of the defective product Munters has thirty days from the date of receipt in which to take action and has the right to examine the product at the customer s premises or at its own plant carriage cost to be borne by the customer Munters at its sole discretion has the option of replacing or repairing free of charge products which it conside...

Страница 31: ...llation tools and consumables required for fitting and installation lubricants necessary for commissioning and maintenance It is mandatory to purchase and use only original spare parts or those recommended by the manufacturer Dismantling and assembly must be performed by qualified technicians and according to the manufacturer s instructions The use of non original spare parts or incorrect assembly...

Страница 32: ...taly Munters Italy S p A Chiusavecchia Phone 39 0183 52 11 Japan Munters K K Phone 81 3 5970 0021 Korea Munters Korea Co Ltd Phone 82 2 761 8701 Mexico Munters Mexico Phone 52 818 262 54 00 Russia Munters AB Phone 7 812 448 5740 Singapore Munters Pte Ltd Phone 65 744 6828 South Africa and Sub Sahara Countries Munters Pty Ltd Phone 27 11 997 2000 Spain Munters Spain S A Phone 34 91 640 09 02 Sweden...