Humidity: Set the humidity level above which air treatment starts. Range 0%-100%
o
Co2: Set the Co2 level above which air treatment starts. Range 0 - 5000
ppm
o
NH3: Set the ammonia level above which air treatment starts. Range: 0 - 100 ppm
13.2
Defining the Air Quality Settings
•
Define:
o
Mode: Select how to compensate air quality:
Off
By Ventilation
By Heat
By Outside Temp (Auto)
o
Outside T⁰ To Operate By Heaters (diff below target): Below this difference from the
target temperature the controller automatically adjusts the heat output to compensate the
air quality. Range -40°to +90°
o
Maximum Additional Ventilation (%): The maximum increase in ventilation (maximum
compensation). Range: 1% to 100%
o
Maximum Additional Heat (%): The maximum increase in heat (max compensation).
Range: 1% to 100%
o
RH Shutoff Differential: (%): Below this level, humidity treatment ceases. Range: 0% to
10%
o
High RH Alarm Threshold (%): Trio sends an alarm when the humidity level rises above
this level. Range: 0% to 100%
o
Co2 Shutoff Differential: (ppm): When CO2 levels are below the target level by this
amount, all CO2 treatment stops. Range: 0 to 500 ppm
o
High Co2 Alarm threshold (ppm): Trio sends an alarm when the CO2 level rises above
this level. Range: 0 to 5000 ppm