![Munters Rotem Trio Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/munters/rotem-trio/rotem-trio_user-manual_1856895067.webp)
© Munters AB, 2020
67
12
Heating Functions
Trio supports up to six (6) on/off heating devices and variable heaters. To control the heat, Trio has two
different programs, one to maintain the target temperature in the entire house and one program that
controls separate heating zones. In the case of the latter, each heater has a dedicated sensor and unique
target temperature.
•
Defining the Central Heater Parameters
•
12.1
Defining the Central Heater Parameters
As temperature drops, Trio reduces the amount of ventilation until it provides the minimum defined
amount. If the temperature goes below the target temperature, Trio continues to run at minimum
ventilation. At the same time, heating begins when the temperature drops to a user defined temperature
(hysteresis).
Define relays and/or analogue output ports as heaters. Refer to the Installation Manual
Configuring On-Off heaters requires mapping one fan, inlet, or outlet, or tunnel door.
1. Go to Climate > Ventilation > Settings.
2. Define:
o
Start Heat Hysteresis: This is a differential. When the temperature drops to the target
temperature minus this amount, heating begins.
o
Heat Cycle: Enable central heaters to work in a cycle.
o
Total Cycle Time (sec.): For heaters defined as cycle heaters, define the cycle time.
o
Min Cycle On Time (sec.): For heaters defined as cycle heaters, define the minimum on
time.
Содержание Rotem Trio
Страница 1: ...User Manual Trio Swine Controller Ag MIS ImEN 2748 09 19 Rev 3 0 P N 116798 Trio Controller ...
Страница 42: ... Munters AB 2020 42 4 Click the fan in the upper right Both fans turn blue 5 Define fans as required ...
Страница 73: ... Munters AB 2020 73 If an outside temperature sensor is enabled map timers to it if required ...