Maintenance and checks 

 

Depending  on  the  operational  conditions,  usually  every  year,  the  heater  should  be  checked  by  qualified 

personnel. 

 

Prior  to  start-up,  the  user  must  check  for  any  evident  non-compliance  with  rules  of  use,  safety  and 

protection

.  

 

5. INSTRUCTIONS FOR USE

 

 

5.1 Start-up 

 

The  heater  is  factory  set  for  operation 

without room thermostat. 

 

If  operation  with  room  (remote) 

thermostat  is  desired,  remove  the  socket 
cover (Fig. 1 nr. 1) and insert the thermostat 
plug into the socket.   

 

Fill the tank with fuel of proper type.

  

 
 
 

 

   Fig.1

 

 

Connect the supply plug to a 115V ~ 60 Hz single phase earthed socket. The green lamp indicates that the 

heater is powered.  

 

WARNING: THE APPLIANCE MUST BE EARTHED 

 

 

Correct 

Incorrect 

 

Indirect fired heaters: connect the heater to a 

chimney  or  to  a  exhaust  duct.  To  get  a  proper 
draught  (at  least  0,1  mbar)  in  the  chimney  the 
exhaust  gas  path  must  rise.    Avoid  any  elbows 
and  bends  in  the  first  part  of  the  exhaust  ducts 
for at least 3 m. For operation of heater in closed 
rooms  without  flue  refer  to  the  instructions  for 
installation (par. 4)  

 

If  a  room  (remote)  thermostat  is  used,  set 

maximum temperature on it. 

 

Turn switch to position “ON” 

 

Set the desired temperature on room 

thermostat. 

 

 

 

5.2. Reset after lockout – Safety air pressure switch 

 

 

The heater is equipped with a Reset pushbutton. When the heater locks out, the red lamp on the pushbutton 

(fig.  1  n°2)  lights  up.  In  this  case  push  the  Reset  button  (see  also  the  par.  “Troubleshooting”)  to  restart  the 
heater.    

 

The  heater  is  also  equipped  with  an  air  pressure  switch  that  controls  the  airflow  pressure  and  locks  the 

heater out in the event of unit overheating. If this occurs, detect and eliminate the cause of overheating before 
using  the  heater  again.  Have  the  heater  inspected  by  a  qualified  technician  if  required.  See  point  above  for 
resetting. 

 
 
 
 

Содержание MIR 37 WU

Страница 1: ...Operating Installation and Service Instructions Direct and Indirect fired Diesel Kerosene Heaters TOR 67 WU TOR 115 WU TOR 175 WU MIR 37 WU MIR 55 WU MIR 85 WU TOR MIR ...

Страница 2: ...________________________________________________________________________________________________ 2 ...

Страница 3: ...ERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALI...

Страница 4: ...0 180 900 288 700 Air Flow Rate ft min 1180 1470 2650 Fuel Types Diesel Kerosene 1 2 Fuel Oil Fuel Consumption gal hr 0 88 1 28 2 04 Fuel Nozzle 0 65 60 H 1 00 60 H 1 50 80 W Efficiency 87 1 87 1 88 5 Noise Level at 2m dB A 75 73 73 Voltage V 115V 60Hz 1ph Electrical Power W 460 460 800 Current Rating A 7 0 7 0 12 5 Weight lb 154 178 282 Lenght in 47 54 8 68 0 Width in 24 27 6 29 5 Height in 31 32...

Страница 5: ...e unit level When a direct fired heater or an indirect fired heater not connected to a flue pipe is used in a closed room provide a minimum opening area of 3 ft2 per US gallon capacity at the unit level and a continuous natural air circulation through windows and doors For the use of the heater the general and special fire safety regulations in force in all fields of applications must be followed ...

Страница 6: ...himney or to a exhaust duct To get a proper draught at least 0 1 mbar in the chimney the exhaust gas path must rise Avoid any elbows and bends in the first part of the exhaust ducts for at least 3 m For operation of heater in closed rooms without flue refer to the instructions for installation par 4 If a room remote thermostat is used set maximum temperature on it Turn switch to position ON Set th...

Страница 7: ...wer Check main distribution board and power supply line Faulty cable connections Check have cable replaced by a qualified electrician Burnt fuse Room thermostat set too low Check and replace if required Set room thermostat on a higher temperature Room thermostat socket cap not inserted Insert cap into the thermostat socket Heater in lock out mode Reset Dirty or faulty flame sensor Clean or replace...

Страница 8: ... Solenoid Valve TR Ignition Transformer M Motor SL Warning Lamp PA Air Pressure Switch FS Fuse FC Flame Sensor PL Reset Button IN Switch TH Remote Thermostat FR Heated Filter TOR 175 WU TH IN FC EV M black green green black white PL TR white EV TR M L N FR TRcont FC PL TH IN PL black black black white white L N FR SL green white red black white white white black M13 M17 M15 M9 M7 M11 M18 M16 M14 M...

Страница 9: ...________________________________________________________________________________________________ 9 ...

Страница 10: ...________________________________________________________________________________________________ 10 ...

Отзывы: