Munters MIR 37 WU Скачать руководство пользователя страница 1

Operating, Installation 
and Service Instructions  
 

 

 
 
 
 

 

 
 
 
Direct- and Indirect-fired  
Diesel/Kerosene Heaters 
 

TOR 67 WU 
TOR 115 WU 
TOR 175 WU 
MIR 37 WU  
MIR 55 WU 
MIR 85 WU 

 

 

 

TOR 
MIR 

 
 

Содержание MIR 37 WU

Страница 1: ...Operating Installation and Service Instructions Direct and Indirect fired Diesel Kerosene Heaters TOR 67 WU TOR 115 WU TOR 175 WU MIR 37 WU MIR 55 WU MIR 85 WU TOR MIR ...

Страница 2: ...________________________________________________________________________________________________ 2 ...

Страница 3: ...ERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALI...

Страница 4: ...0 180 900 288 700 Air Flow Rate ft min 1180 1470 2650 Fuel Types Diesel Kerosene 1 2 Fuel Oil Fuel Consumption gal hr 0 88 1 28 2 04 Fuel Nozzle 0 65 60 H 1 00 60 H 1 50 80 W Efficiency 87 1 87 1 88 5 Noise Level at 2m dB A 75 73 73 Voltage V 115V 60Hz 1ph Electrical Power W 460 460 800 Current Rating A 7 0 7 0 12 5 Weight lb 154 178 282 Lenght in 47 54 8 68 0 Width in 24 27 6 29 5 Height in 31 32...

Страница 5: ...e unit level When a direct fired heater or an indirect fired heater not connected to a flue pipe is used in a closed room provide a minimum opening area of 3 ft2 per US gallon capacity at the unit level and a continuous natural air circulation through windows and doors For the use of the heater the general and special fire safety regulations in force in all fields of applications must be followed ...

Страница 6: ...himney or to a exhaust duct To get a proper draught at least 0 1 mbar in the chimney the exhaust gas path must rise Avoid any elbows and bends in the first part of the exhaust ducts for at least 3 m For operation of heater in closed rooms without flue refer to the instructions for installation par 4 If a room remote thermostat is used set maximum temperature on it Turn switch to position ON Set th...

Страница 7: ...wer Check main distribution board and power supply line Faulty cable connections Check have cable replaced by a qualified electrician Burnt fuse Room thermostat set too low Check and replace if required Set room thermostat on a higher temperature Room thermostat socket cap not inserted Insert cap into the thermostat socket Heater in lock out mode Reset Dirty or faulty flame sensor Clean or replace...

Страница 8: ... Solenoid Valve TR Ignition Transformer M Motor SL Warning Lamp PA Air Pressure Switch FS Fuse FC Flame Sensor PL Reset Button IN Switch TH Remote Thermostat FR Heated Filter TOR 175 WU TH IN FC EV M black green green black white PL TR white EV TR M L N FR TRcont FC PL TH IN PL black black black white white L N FR SL green white red black white white white black M13 M17 M15 M9 M7 M11 M18 M16 M14 M...

Страница 9: ...________________________________________________________________________________________________ 9 ...

Страница 10: ...________________________________________________________________________________________________ 10 ...