MEK-36,48,58 / MAK-36,48,58
Issue 12.2009/Rev. 02
Page 9/20
Melt and preheat temperatures are controlled
separately. The setpoint and momentary values are
displayed concurrently.
The melt temperature must have reached the preset
start interlock temperature for the startup timer to
be activated. After the startup timer has timed out,
the start interlock will be released and the extruder
can be started.
The temperature-controlled start interlock prevents
the drive from starting if there is still unmolten
material in the extruder, thus precluding damage to
the unit.
The output rate is variable so that the preheat
temperature can be matched to the weld thickness.
5 Startup and Shutoff
5.1 General
In addition to the operating instructions and the
national and local accident prevention regulations
applicable at the place of use, the acknowledged
technical rules for safe and proper working practices
must be observed.
Any working practices posing a safety risk are
prohibited.
Before starting / shutting off the hand extruder, make
sure to carefully read the instructions under section
“Safety”.
Only trained and qualified personnel may be
assigned to the operation of the hand extruder.
5.2 Preparation
•
Place hand extruder on a firm support and secure
it against toppling over as shown in the
illustration.
•
Mount hot air hood
•
Position handle
Loosen handle (55) and move it to the ideal
working position by pushing it back and forth. The
extruder handles can be additionally swivelled
upward and downward, so that the machine can
be operated by both right-handed and left-handed
persons.
•
Position T-grip on “landfill” extruder version
To rotate the T-grip, loosen it and then retighten it
in the desired position.
•
Only for type MEK hand extruder with external
air supply:
Connect the hand extruder to the external air
source using the hose coupling LW 13 / NM 7.2
provided for this purpose (quick connect-
disconnect); set air rate to 300 l/min at 0.4 bar. A
suitable controller with flow metering function is
recommended for setting the air rate.
CAUTION The supply air must be clean, dry and
free from oil and water.
Never connect an external air source to a
MAK hand extruder.