Munsch MAK-36 Скачать руководство пользователя страница 9

 
 

 

 

 

MEK-36,48,58 / MAK-36,48,58 

Issue 12.2009/Rev. 02 

Page 9/20 

 

Melt and preheat temperatures are controlled 
separately. The setpoint and momentary values are 
displayed concurrently. 
 

 

The melt temperature must have reached the preset 
start interlock temperature for the startup timer to 
be activated. After the startup timer has timed out, 
the start interlock will be released and the extruder 
can be started. 

 
 

The temperature-controlled start interlock prevents 
the drive from starting if there is still unmolten 
material in the extruder, thus precluding damage to 
the unit.  

 

The output rate is variable so that the preheat 
temperature can be matched to the weld thickness. 
 

5  Startup and Shutoff 

5.1  General  
In addition to the operating instructions and the 
national and local accident prevention regulations 
applicable at the place of use, the acknowledged 
technical rules for safe and proper working practices 
must be observed. 

 

Any working practices posing a safety risk are 
prohibited. 

 

Before starting / shutting off the hand extruder, make 
sure to carefully read the instructions under section 
“Safety”. 

 

Only trained and qualified personnel may be 
assigned to the operation of the hand extruder. 
 
5.2  Preparation 

  Place hand extruder on a firm support and secure 

it against toppling over as shown in the 
illustration.  

 

 

 

 

  Mount hot air hood   

 

  Position handle  

Loosen handle (55) and move it to the ideal 
working position by pushing it back and forth. The 
extruder handles can be additionally swivelled 
upward and downward, so that the machine can 
be operated by both right-handed and left-handed 
persons. 

 

  Position T-grip on “landfill” extruder version   

To rotate the T-grip, loosen it and then retighten it 
in the desired position.  

 

  Only for type MEK hand extruder with external 

air supply: 
Connect the hand extruder to the external air 
source using the hose coupling LW 13 / NM 7.2 
provided for this purpose (quick connect-
disconnect); set air rate to 300 l/min at 0.4 bar. A 
suitable controller with flow metering function is 
recommended for setting the air rate.

 

 

 

CAUTION The supply air must be clean, dry and 

free from oil and water.  

 

Never connect an external air source to a  
MAK hand extruder. 

Содержание MAK-36

Страница 1: ..._________ MEK 48 MAK 48 Article No ______________ MEK 58 MAK 58 These operating instructions contain important information to be observed for hand extruder operation and maintenance It is therefore im...

Страница 2: ...CTION AND MOUNTING 7 2 7 UNAUTHORIZED MODIFICATIONS AND SPARE PARTS 7 3 TRANSPORT AND STORAGE 8 3 1 TRANSPORT 8 3 2 STORAGE 8 3 3 RETURN TO MUNSCH 8 4 PRODUCT DESCRIPTION 8 4 1 APPLICATION RANGE 8 4 2...

Страница 3: ...ing harmonised standards or parts of these standards were applied DIN EN ISO 12100 1 2004 DIN EN 13732 1 2008 DIN EN ISO 12100 2 2004 In addition the hand extruders are in accordance with the followin...

Страница 4: ...eover failure to observe the safety instructions may lead to the forfeiture of any damages Non observance of the safety instructions may in particular involve the following risks failure of important...

Страница 5: ...age of not less than 230 V 1 must be available at the connector of the hand extruder When using an extension cable make sure to observe the minimum conductor cross section Use extension cables with pr...

Страница 6: ...t air supply risk of hand extruder damage When using an external air source make sure that the air supply line is adequately dimensioned CAUTION The supply air must be clean dry and free from oil and...

Страница 7: ...nspection and mounting activities are performed by authorized and qualified personnel who are thoroughly familiar with the operating instructions As a rule the hand extruder must be shut off and the c...

Страница 8: ...lication range of the hand extruder is defined by the data on the type tag and the service limits indicated in these operating instructions CAUTION Operation of the hand extruder outside the service l...

Страница 9: ...fore starting shutting off the hand extruder make sure to carefully read the instructions under section Safety Only trained and qualified personnel may be assigned to the operation of the hand extrude...

Страница 10: ...material over the entire joint width at as low a hot air temperature as possible For larger weld seam widths a wider preheat nozzle is available as an accessory 5 3 Starting the hand extruder Observe...

Страница 11: ...the welding rod 5 4 2 Replacement and aging of welding rod If the welding rod is to be replaced make sure that any remaining rod in the hand extruder is completely removed For this purpose operate th...

Страница 12: ...on once to switch off the heating circuits Pull mains connector Maintain the air supply of the hand extruder until the unit has completely cooled down Never use water or another coolant to accelerate...

Страница 13: ...MEK 36 48 58 MAK 36 48 58 Issue 12 2009 Rev 02 Page 13 20...

Страница 14: ...er working practices must be observed Any working practices posing a safety risk are prohibited Activities other than those described in this section may only be performed at the Manufacturer s worksh...

Страница 15: ...MEK 36 48 58 MAK 36 48 58 Issue 12 2009 Rev 02 Page 15 20...

Страница 16: ...mperature 2 3 4 8 10 18 22 14 Melt temperature below setpoint temperature 2 3 9 11 14 Extruder does not heat up 2 3 12 22 Temperature above preset range 2 3 18 19 Controller fault signal E 2 Controlle...

Страница 17: ...Rated voltage permissible voltage Check mains voltage Rated voltage permissible voltage Check mains voltage 1 15 Extension cable heats up Unroll cable reel Check cable cross section see also section...

Страница 18: ...0 mm and film sheeting welds 48 Wall thicknesses 10 35 mm and film sheeting welds 58 Wall thicknesses 12 40 mm and film sheeting welds Weight 36 48 9 kg 58 10 kg 36 48 9 2 kg 58 10 2 kg Drive 230 V AC...

Страница 19: ...t to be free from defects in materials and workmanship from the date of its first acquisition Should deficiencies resulting from defects in materials or workmanship be identified during the warranty p...

Страница 20: ...efect the Purchaser may demand annulment cancellation of the contract or a price reduction reduction of compensation in lieu of remedial work In such a case the Purchaser shall not be entitled to any...

Отзывы: