Be sure to be in conformity with the local, national and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The following precautions include important safty items. 
Observe them and never forget.

Keep this manual with the owner's manual in a handy place 
for future reference.

1.    PRECAUTIONS

The safty precautions listed here are divided into two categories. In 
either case, important safty information is listed which must be read 
carefully.

After completing the installation, make sure that the unit operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.Also, inform 
customers that they should store this installation manual along with 
the owner's manual for future reference.  

Be sure only trained and qualified service personnel to 
install, repair or service the equipment.

Improper installation, repair, and maintenance may result in 
electric shocks, short-circuit, leaks, fire or other damage to 
the equipment.

Disconnect the power supply before cleaning and 
maintenance.

Failure to observe a warning may result in death.

Failure to observe a caution may result in injury or 
damage to the equipment.

Install according to this installation instructions strictly. 

If installation is defective, it will cause water leakage, 
electrical shock fire.

When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

Use the attached accessories parts and specified parts 
for installation. 

otherwise, it will cause the set to fall, water  leakage, 
electrical shock fire.

Install at a strong and firm location which is able to 
withstand the set' s weight. 

If the strength is not enough or installation is not properly 
done, the set will drop to cause injury.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits 
must be disconnected.

The appliance must be positioned so that the plug is 
accessible.

The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow.

For electrical work, follow the local national wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

If electrical circuit capacity is not enough or defect in 
electrical work, it will cause electrical shock fire.

Use the specified cable and connect tightly and clamp 
the cable so that no external force will be acted on the 
terminal.

 

If connection or fixing is not perfect, it will cause heat-up or 
fire at the connection.

Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical 
shock.

If the supply cord is damaged, it must be replaced by the 
manufacture or its service agent or similarly qualifued 
person in order to avoid a hazard.

An all-pole disconnection swith having a contact 
separation of at least 3mm in all poles should be 
connected in fixed wiring.

When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

Otherwise, it will cause lower capacity, abnormal high 
pressure in the refrigeration cycle, explosion and injury.

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

Otherwise, it will cause fire or electrical shock.

Carry out the specified installation work after taking into 
account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling 
and causing accidents.

CAUTION

WARNING

WARNING

CONTENTS

PAGE

PRECAUTIONS........................................................................................1
INSTALLATION INFORMATION............................................................... 2
ACCESSORIES  ......................................................................................3
INSPECTING AND HANDLING THE UNIT.................................................4
INDOOR UNIT INSTALLATION.................................................................4
CONNECT THE DRAIN PIPE....................................................................6
INSTALL THE CONNECTING PIPE...........................................................6
WIRING...................................................................................................9
CONTROL..............................................................................................12

9.1 Main board Code designation

Installation manual

Console

1

TEST OPERATION.................................................................................14

TROUBLESHOOTING..................................................................13

Содержание CL23220

Страница 1: ...MVD Installation manual English CL23220 to CL23223 Console www mundoclima com...

Страница 2: ...The appliance shall not be installed in the laundry Before obtaining access to terminals all supply circuits must be disconnected The appliance must be positioned so that the plug is accessible The en...

Страница 3: ...t 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves a distance of 1 meter may not be sufficient enough to eliminate the noise The app...

Страница 4: ...improvement without further notices Cautions on remote controller installation Remote controller holder Mounting screw B ST2 9x10 C H QUANTITY SHAPE NAME 1 Hook 8 Installation manual 3 Remote control...

Страница 5: ...under which the electric wave is generated even if 1 meter is kept When run some of the units among the indoor units in heating mode voice of refrigeration flowing comes from some other non operating...

Страница 6: ...oor unit Refer to Fig 5 5 Fig 5 6 Fig 5 8 Fig 5 4 195mm Hook Tapping screw Washer mm Removing front grille 1 Open the front panel 2 Remove the 4 screws and remove the front grille while pulling it for...

Страница 7: ...ation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail The outlet has PTI screw bread Please use sealing materials and...

Страница 8: ...o Fig 7 3 Fig 7 3 Remove the front panel 2 Remove the string Refer to Fig 7 2 Allowing the front panel to fall forward will enable you to remove it Fig 7 2 Cover the joints of the connecting pipe with...

Страница 9: ...turn the valve clockwise with the hexagon wrench Securely tighten the valve until the shaft contacts the main bodyseal CAUTION CAUTION Always use a charge hose for service port connection After tighte...

Страница 10: ...o apply for products like washing machines air conditioners or electrical ovens The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube 1 2...

Страница 11: ...erminal block of indoor and outdoor units Re install the Indoor unit and outdoor unit The Specification of Power 8 3 8 4 Wiring of Indoor Unit Power Supply and Signal Wire The indoor unit should use d...

Страница 12: ...0 C For the third code ON super high fan speed OFF extreme super high fan speed 1 2 3 Temperature corrected code 0 means in the heating T1 TS 0 C the units capacity should be 0 Temperature corrected...

Страница 13: ...r fan is 4 minutes 01 means the time of stopping indoor fan is 8 minutes 10 means the time of stopping indoor fan is 12 minutes 11 means the time of stopping indoor fan is 16 minutes 6 21 6 21 6 21 6...

Страница 14: ...and then switch on it If you don t switch on the power the capacity you set can not implement Installation manual Cassette 4 way compact 13 Table 10 1 NO Type Contents LED Lamp flash Remarks The evapo...

Страница 15: ...conditioner is pre heated by turning on the power Set the air conditioner under the mode of COOLING with the remote controller and check the following points If there is any malfunction please resolv...

Страница 16: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 MVD www mundoclima com...

Отзывы: