Appendix B – Antenna for the Wireless RouteFinder
Multi-Tech Systems, Inc. RouteFinder RF825/RF825-AP User Guide (Document Number S000422B)
93
Appendix B – Antenna for the
Wireless RouteFinder
The Access Point Antenna
Your ship kit for the wireless RouteFinder includes a 2.4 GHz 5dBi SWI-Reverse-F Swivel Antenna.
Important Notes:
•
The antenna for this product must be a reverse polarity SMA antenna.
•
The antenna must be attached in order for the RouteFinder access point to be operational.
Antenna Electrical Characteristics
Frequency:
2400 to 2500 MHZ
Gain:
4.5dBi (nominal)
VSWR:
≤
2
Polarization:
Linear, Vertical
Maximum Power:
20W
Impedance:
50
Ω
Connector:
RP-SMA Plug
Reverse Polarity Meets FCC Part 15.203 Requirements
Mechanical
Testing Condition Note:
Non-operating during test.
Endurance
Number of connection/disconnection of the connector: 500 cycles
Number of 360
°
rotation of the connector: 1000 cycles
Mandatory: Guaranty of functionalities after test
Bending
Number of 90
°
at the hinge parts and bending on one direction with 1kg force: 1000 cycles
Mandatory: No mechanical damage tolerated. Guaranty of functionalities after test.
Antenna Resistance
Tests are applicable to all parts and both sides.
Traction
Tractions force applied 3 times on plugs during 15 seconds: 5kg
Mandatory: No mechanical damage tolerated. Guaranty of functionalities after test.
Environmental
Storage
Condition: Non-operating during test.
Cold:
-40
°
C during 72h (IEC 68-2-1 standard Ab/Ad test)
Dry Heat: +80
°
C during 96h (IEC 68-2-2 standard Bb/Bd test)
Humidity:
+40
°
C at 95% R.H. during 4 days (IEC 68-2-56 standard Cb test)
Mandatory: No mechanical or visible damage tolerated. Guaranty of functionalities after test.
Operation
Condition: Operating during test.
Cold:
-10
°
C during 48h (IEC 68-2-1 standard Ab/Ad test)
Dry Heat: +55
°
C during 48h (IEC 68-2-2 standard Bb/Bd test)
Humidity:
-10
°
C to +55
°
C at 95% R.H. 4 cycles (IEC 68-2-30 standard Nb test)
Mandatory: No mechanical or visible damage tolerated. Guaranty of functionalities during and after