Glossary

42

MultiModemZPX User Guide

Serial Bus. The Device Address is the Default Address when the
Universal Serial Bus device is first powered or reset. Hubs and
functions are assigned a unique Device Address by Universal
Serial Bus software.

Device driver: 

Software that controls how a computer

communicates with a device, such as a printer or mouse.

Digital Cross-connect System (DCS): 

The CO device which

splits and redistributes the T1 bandwidth. the DCS takes time
slots from various T1 lines and alters them to provide the
needed connectivity. DCS connections are made with software
at an administrator’s workstation.

Digital Data: 

Information represented by discrete values or

conditions (contrast “Analog Data”).

Digital Loopback: 

A technique used for testing the circuitry of

a communications device. Can be initiated locally, or remotely
(via a telecommunications device). The tested device decodes
and encodes a received test message, then echoes the
message back. The results are compared with the original
message to determine if corruption occurred en route.

Digital PBX: 

A Private Branch Exchange that operates

internally on digital signals. See also “Exchange”.

Digital Service, level 0 (DS0): 

The world-wide standard speed

(64 Kbps) for digital voice conversation using PCM (pulse
coded modulation).

Digital Service, level 1 (DS1): 

The 1.544M bps voice standard

(derived from an older Bell System standard) for digitized voice
transmission in North America. The 1.544M bps consists of 24
digitally-encoded 64 Kbps voice channels (north America) and
2.048M bps (30 channels) elsewhere.

Digital Signal: 

A discrete or discontinuous signal (e.g., a

sequence of voltage pulses). Digital devices, such as terminals
and computers, transmit data as a series of electrical pulses
which have discrete jumps rather than gradual changes.

Digital Signaling Rates (DSn): 

A hierarchical system for

transmission rates, where “DS0” is 64 Kbps (equivalent to ISDN
B channel), and DS1 is 1.5 Mbps (equivalent to ISDN PRI).

Digital Transmission: 

A method of electronic information

transmission common between computers and other digital
devices. Analog signals are waveforms: a combination of many
possible voltages. A computer’s digital signal may be only “high”
or “low” at any given time. Therefore, digital signals may be
“cleaned up” (noise and distortion removed) and amplified
during transmission.

Digitize: 

To convert an analog signal to a digital signal.

DIP switch (pronounced “dip switch”): 

A set of tiny toggle

switches, built into a DIP (dual in-line package), used for setting
configurable parameters on a PCB (printed circuit board).

Downstream

: The direction of data flow from the host or away

from the host. A downstream port is the port on a hub
electrically farthest from the host that generates downstream
data traffic from the hub. Downstream ports receive upstream
data traffic.

Driver

: When referring to hardware, an I/O pad that drives an

external load. When referring to software, a program responsible
for interfacing to a hardware device; that is, a device driver.

Drop and Insert: 

The process where a portion of information

carried in a transmission system is demodulated (“Dropped”) at
an intermediate point and different information is included
(“Inserted”) for subsequent transmission.

DTE (Data Terminal Equipment): 

A term used to include any

device in a network which generates, stores or displays user
information. DTE is a telecommunications term which usually
refers to PCs, terminals, printers, etc.

DTMF (Dual-Tone MultiFrequency): 

A generic push-button

concept made popular by AT&T TouchTone.

DWORD

: Double word. A data element that is 2 words, 4 bytes,

or 32 bits in size.

Dynamic Insertion and Removal

:  the ability to attach and

remove devices while the host is in operation.

E

E&M: 

A telephony trunking system used for either switch-to-

switch, or switch-to-network, or computer/telephone system-to-
switch connection.

EIA: 

The Electronics Industries Association is a trade

organization in Washington, DC that sets standards for use of
its member companies. (See RS-232, RS-422, RS530.)

Encapsulation: 

A technique used by network-layer protocols in

which a layer adds header information to the protocol data unit
from the preceding layer. Also used in “enveloping” one protocol
inside another for transmission. For example, IP inside IPX.

End User

: The user of a host.

Endpoint

: See Device Endpoint.

Endpoint Address

: The combination of a Device Address and

an Endpoint Number on a Universal Serial Bus device.

Endpoint Number

: A unique pipe endpoint on a Universal

Serial Bus device.

Ethernet: 

A 10-megabit baseband local area network that

allows multiple stations to access the transmission medium at
will without prior coordination, avoids contention by using carrier
sense and deference, and resolves contention by using collision
detection and transmission. Ethernet uses carrier sense
multiple access with collision detection (CSMA/CD).

Excess Zeros: 

A T1 error condition that is logged when more

than 15 consecutive 0s or fewer than one 1 bit in 16 bits occurs.

Exchange: 

A unit (public or private) that can consist of one or

more central offices established to serve a specified area. An
exchange typically has a single rate of charges (tariffs) that has
previously been approved by a regulatory group.

Exchange Area: 

A geographical area with a single uniform set

of charges (tariffs), approved by a regulatory group, for
telephone services. Calls between any two points within an
exchange area are local calls. See also “Digital PBX”, “PBX”.

Exchange Termination (ET): 

The carrier’s local exchange

switch. Contrast with “Loop Termination - LT”.

Explicit Congestion Management: 

The method used in frame

relay to notify the terminal equipment that the network is overly
busy. The use of FECN and BECN is called explicit congestion
management. Some end-to-end protocols use FECN or BECN,
but usually not both options together. With this method, a
congestion condition is identified and fixed before it becomes
critical. Contrast with “implicit congesion”.

Extended Super Frame (ESF): 

One of two popular formats for

framing bits on a T1 line. ESF framing has a 24-frame super-
frame, where robbed bit signaling is inserted in the LSB (bit 8 of
the DS-0 byte) of frames 6, 12, 18 and 24. ESF has more T1
error measurement capabilities than D4 framing. Both ESF and
B8ZS are typically offered to provide clear channel service.

F

Failed Seconds: 

A test parameter where the circuit is

unavailable for one full second.

Failed Signal: 

A T1 test parameter logged when there are more

than 9 SES (Severely Errored Seconds).

Fax (facsimile): 

Refers to the bit-mapped rendition of a

Содержание MultiModem MT5634ZPX-V.92-ISA

Страница 1: ...MultiModem ZPX MT5634ZPX V 92 ISA Internal ISAData Fax Modem User Guide...

Страница 2: ...Multi Tech logo are trademarks of Multi Tech Systems Inc Adobe and Acrobat are trademarks of Adobe Systems Incorporated MNP is a trademark of Microcom Inc Microsoft Windows Windows 98 Windows Me Windo...

Страница 3: ...Telephone Line 17 Step 8 Configure the Modem for Your Country 18 AT Commands 18 Data Communications Software 18 Chapter 3 Using Your Modem 19 Operating Your MultiModemZPX 19 Testing Your Modem 19 Tes...

Страница 4: ...and R TTE Directive Compliance 33 International Modem Restrictions 33 New Zealand Telecom Warning Notice 33 Appendix B Updating Your Modem s Firmware 35 Introduction 35 Upgrade Overview 35 Appendix C...

Страница 5: ...des quick connections downstream transmissions at speeds up to 56K bps and upstream transmissions at speeds up to 48K bps when connected to V 92 compatible Internet service providers Transmissions bet...

Страница 6: ...lower speeds in noisy line conditions and fall forward to faster speeds as conditions improve line quality monitoring ITU V 42 LAP M and MNP Class 3 and 4 error correction ITU V 42bis 4 to 1 and MNP 5...

Страница 7: ...tup for operation within your country Chapter 3 Using your Modem In this chapter instructions are provided for configuring your communications software and Windows Dial up Networking The chapter also...

Страница 8: ...TR29 2 Video Compatibility ITU T V 80 for H 34 video conferencing Error Correction ITU T V 42 LAP M or MNP 4 Data Compression ITU T V 44 4 1 throughput V 42bis 4 1 throughput MNP 5 2 1 throughput Spe...

Страница 9: ...pecific cord for UK and International models one 9 pin to 25 pin serial cable for UK and International models external power transformer and cord Diagnostics Local analog loop local digital loop remot...

Страница 10: ...open your computer A nearby telephone line jack Safety Warnings Use this product only with UL and CUL listed computers U S A To reduce the risk of fire use only UL listed 26 AWG 41mm or larger teleph...

Страница 11: ...n use on your system The best way to check what resources are in use and which ones are available run WINMSD Utility 1 To check the system resources click Start I Run 2 Enter WINMSD in the Open window...

Страница 12: ...IRQs to display the used IRQs The MultiModemZPX only uses IRQs 3 4 and 5 so you need to check in the above screen to see if any of these IRQs are available The MultiModemZPX is defaulted to IRQ 5 5 Re...

Страница 13: ...lick on I O to display the available I O addresses 7 The MultiModemZPX uses the following I O addresses COM1 3F8 3FF COM2 2F8 2FF COM3 3E8 3EF COM4 2E8 2EF and is defaulted to COM 4 8 Record the avail...

Страница 14: ...efault position to your new position that supports your application 3 To change the COM port assignment from the default COM4 move the two berg jumpers from their default positions to your new positio...

Страница 15: ...izard Properties screen appears click on Set Configuration Manually option and ckick OK 9 The Add Hardware Wizard Properties window for Communications Port COM3 is dis played In the Setting based on w...

Страница 16: ...lick on the MT5634ZPX V92 option and click Next 9 The Select the port s you want to install the modem on screen appears Highlight the COM port On which ports do you want to install it This is the COM...

Страница 17: ...MultiModemZPX to your telephone wall jack If you don t have a standard modular wall jack near your computer install one or have one installed for you by your telephone company In the U S installation...

Страница 18: ...When Global Wizard announces that the parameters have been set click Finish to exit AT Commands Non Windows users can configure the modem using AT commands You must enter these commands in your commun...

Страница 19: ...or Dial Up Networking session through a set of modem configurations that you select and then associate with a target telephone number Testing Your Modem Testing Data Functions You can test your modem...

Страница 20: ...pose and then New Fax Remote Configuration Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location With password protected remo...

Страница 21: ...ith OK 4 The new password is saved automatically You now can enter more AT commands or exit the data communications program The next time you remotely configure the modem you must use the new setup pa...

Страница 22: ...Web site Fax Commands Fax commands resemble AT commands but are more complicated to use Because of this we recommend that you use a fax program to send and receive faxes rather than attempting to cont...

Страница 23: ...ion for a description and possible solution to your problem Common Problems The following is a list of common problems associated with using a modem The modem does not respond to commands The modem di...

Страница 24: ...lict If you need to change switches or jumpers on the conflicting device refer to the device s documentation If you have another MultiModemZPX install it and try to make a connection The modem dials b...

Страница 25: ...so try calling the modem s phone number from your telephone If you hear harsh sounds a modem is answering the call If the modem is answering the modems may be having problems negotiating due to modem...

Страница 26: ...od you selected in your software matches the method selected in the modem see AT commands Kn and Qn Try entering the V View Parameters command making a screen print of the diagnostics listing and chec...

Страница 27: ...ILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS Repair Procedures for U S and Canadian Customers In the event that service is required products may be shipped freight prepaid to our Mounds View Minnesot...

Страница 28: ...the problem a return shipping address must have street address not P O Box your telephone number and if the product is out of warranty a check drawn on a U S bank or your company s purchase order for...

Страница 29: ...reseller may offer the quickest and most economical repair option for your Multi Tech product You may also contact any Multi Tech sales office for information about the nearest distributor or other r...

Страница 30: ...p you get the most out of your Multi Tech product If you have any questions about the operation of this unit please call 800 972 2439 USA and Canada or 763 717 5863 international and local Please have...

Страница 31: ...rk the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify you as soon as pos...

Страница 32: ...pt any interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to o...

Страница 33: ...rticularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate...

Страница 34: ...equipment may give rise to bell tinkle or noise and may also cause a false answer condition Should such problems occur the user should NOT contact the Telecom Faults Service The preferred method of di...

Страница 35: ...You must know the model number and firmware version of your Multi Tech modem to know whether you should update it 1 Run your favorite terminal program If you are using Windows 98 Windows NT or Window...

Страница 36: ...en the program finishes copying files to your computer the Setup Complete dialog box displays indicating that you must restart your computer before using the program 8 Select Yes then Finish to restar...

Страница 37: ...mber listed in the Hex File list click Cancel to end the update process b If your modem s firmware version number is lower than the firmware version shown in the Hex File list continue with the update...

Страница 38: ...13 19 3 33 51 S 53 83 s 73 115 T DC4 14 20 4 34 52 T 54 84 t 74 116 U NAK 15 21 5 35 53 U 55 85 u 75 117 V SYN 16 22 6 36 54 V 56 86 v 76 118 W ETB 17 23 7 37 55 W 57 87 w 77 119 X CAN 18 24 8 38 56...

Страница 39: ...of specified percentages per the WEEE requirements Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging which indicates that th...

Страница 40: ...ommunication line control that uses a standard set of transmission control characters and control character sequences for binary synchronous transmission of binary coded data between stations Bit Bina...

Страница 41: ...ort on a PC Congestion A network condition where there is too much data traffic The ITU I 233 standard defines congestion managemennt in terms of speed and burstiness Congestion notification The funct...

Страница 42: ...ation is included Inserted for subsequent transmission DTE Data Terminal Equipment A term used to include any device in a network which generates stores or displays user information DTE is a telecommu...

Страница 43: ...e with a pointing device H Handshaking A process that two modems go through at the time of call setup to establish synchronization over the data communications link It is a synchronization and negotia...

Страница 44: ...formation on the T1 line is included in the form of 1s in the data stream a long string of 0s in the data stream could cause problems recovering the data Line Termination LT The electronics at the ISD...

Страница 45: ...bank Off hook The condition of a device which has accessed a phone line with or without using the line In modem use this is equivalent to a phone handset being picked up Dialing and transmission are...

Страница 46: ...ommunications services Pulse Code Modulation PCM 1 In data communication variation of a digital signal to represent information for example by means of pulse amplitude modulation PAM pulse duration mo...

Страница 47: ...Network Architecture SNA The description of the logical structure formats protocols and operational sequences for transmitting information units through and controlling the configuration and operation...

Страница 48: ...put etc are made using the A type connector downstream connections peripherals hub outputs are made using the B type connector The USB spec defines two types of connectors to protect the bus from ille...

Страница 49: ...ta communications network designed to serve an area of hundreds or thousands of miles for example public and private packet switching networks and national telephone networks Contrast with local area...

Страница 50: ...r Group 3 8 ITU T V 21 8 ITU T V 34 fax 5 ITU T V 42 8 ITU T V 44 8 ITU T V 80 8 ITU T V 92 protocol 5 M Multi Tech Internet sites 30 MultiModemZPX 5 O ordering replacement parts 30 P pulse and tone d...

Страница 51: ...V V 17 8 V 22 8 V 22bis 8 V 27ter 8 V 29 8 V 3 8 V 32 8 V 34 8 V 34 enhanced 8 V 34bis 8 V 42 8 V 42 error correction 5 V 42bis 5 8 V 44 8 V 44 data compression 5 V 90 8 V 92 8 W warranty 27 31 X XON...

Отзывы: