MT5634ZPW-PCI
44
Owner’s Manual
Command:
&K
n
Local Flow Control Selection
Values:
n = 0, 3, or 4
Defaults:
3
Description:
&K0
Flow control disabled.
&K3
Enable CTS/RTS hardware flow control.
&K4
Enable XON/XOFF software flow control.
Command:
&M
n
Communications Mode
Values:
n = 0
Defaults:
0
Description:
&M0
Asynchronous mode.
&M1
Reserved—responds ERROR.
Command:
&Q
n
Asynchronous Communications Mode
Values:
n = 0, 5, or 6
Defaults:
5
Description:
&Q0
Asynchronous with data buffering. Same as
\N0.
&Q5
Error control with data buffering. Same as
\N3.
&Q6
Asynchronous with data buffering. Same as
\N0.
Command:
&S
n
Data Set Ready (DSR) Control
Values:
n = 0 or 1
Default:
0
Description:
&S0
Force DSR high (on).
&S1
Let DSR follow CD.
Command:
&T
n
Self-Test Commands
Values:
n = 0, 1, 3 or 6
Default:
None
Description:
&T0
Abort. Stop any test in progress.
&T1
Local analog loop test.
&T3
Local digital loopback test.
&T6
Remote digital loopback test.
Command:
&V
View Current Configuration
Values:
n/a
Description:
Displays the active modem settings.
Содержание MultiModem MT5634ZPW-PCI
Страница 1: ...Model Number MT5634ZPW PCI Owner s Manual...
Страница 6: ...vi...
Страница 7: ...Chapter 1 Introduction and Description...
Страница 15: ...Chapter 2 Installation...
Страница 32: ...MT5634ZPW PCI 32 Owner s Manual...
Страница 33: ...Chapter 3 AT Commands S Registers and Result Codes...
Страница 54: ...MT5634ZPW PCI 54 Owner s Manual...
Страница 55: ...Chapter 4 Troubleshooting...
Страница 65: ...Chapter 5 Warranty Service and Technical Support...
Страница 75: ...Appendices...