PAGE 14 — QP4TH TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #3 (01/29/14)
PUMP COMPONENTS
Figure 3 shows a typical application using the QP4TH centrifugal pump. Please note that this pump is intended for the
removal of clean water.
Figure 3. QP4TH Pump Application
NOTE:
CONTACT YOUR NEAREST
MULTIQUIP DEALER FOR
QUICK DISCONNECT HOSES
AND FITTINGS.
1
3
4
5
7
6
4
8
9
11
12
4
3
2
10
1.
Pump — The model QP4TH is a 4-inch trash pump
aused in general dewatering applications.Typical
dewatering applications consist of manholes, septic
tanks, fast and slow seepage ditch water, silt water,
mud water and muck water.
2.
Fill Cap — Prior to operation, the pump casing should
be filled with water. Remove this cap to add water to
the pump. After the initial prime, a sufficient amount of
water will be retained in the casing so that the operator
will not need to re-prime later.
3.
Discharge Port — Connect a 4-inch discharge hose
to this port.
4.
Worm Clamp — Used to secure the hose to the inlet
and outlet ports on the pump. Use two clamps to secure
the hose on the inlet side of the pump.
5.
Discharge Hose — Connect a flexible rubber
hose to the discharge port on the pump. Make sure
that the hose lays flat and is not kinked. Use only
recommended type discharge hose. Contact Multiquip
Parts Department for ordering information.
6.
Suction Port — Connect a 3-inch inlet hose to this port
Use two worm clamps to secure the hose.
7.
Suction Hose — Connect this flexible rubber hose to
the suction port on the pump. Make sure that the hose
lays flat and is not kinked. Use only recommended type
suction hose. Contact Multiquip parts department for
ordering information.
8.
Clean-out Cover Handles — To gain access to the
pump's clean-out area, grip both handles, then pull to
remove cover. Make sure both locking knobs have been
released before attempting to remove clean-out cover.
9.
Drain Plug — Remove this plug to drain water from
the pump.
10.
Clean-out Cover — Remove cover to gain access to
the clean-out area.
11.
Locking Knobs — Turn both knobs clockwise to
secure clean-out cover, turn counter-clockwise to
release cover.
12.
Strainer — Always attach a strainer to bottom side of
the suction hose to prevent large objects and debris
from entering the pump. Strainer should be positioned
so that it will remain completely under water. Running
the pump with the strainer above water for long periods
can damage pump.
Содержание QP4TH
Страница 2: ...PAGE 2 QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 PROPOSITION 65 WARNING...
Страница 3: ...QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 PAGE 3 NOTES...
Страница 21: ...QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 PAGE 21 MAINTENANCE PUMP Figure 18 Pump Vacuum Tester...
Страница 30: ...PAGE 30 QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 PUMP ASSEMBLY...
Страница 32: ...PAGE 32 QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 PUMP ASSEMBLY...
Страница 34: ...PAGE 34 QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 ENGINE SERVICE PARTS...
Страница 37: ...QP4THTRASH PUMP OPERATION AND PARTS MANUAL REV 3 01 29 14 PAGE 37 NOTES...