PAGE 40 —GBX24S/GBX24B LIGHT TOWER • OPERATION AND PARTS MANUAL — REV. #0 (05/30/19)
Table 13. Lamp Troubleshooting (GBX24S continued)
SYMPTOM
POSSIBLE PROBLEM
SOLUTION
Lamps only lights for a short time.
Error indicators of the lighting units flash
twice continuously?
Voltage of the LED power supply output.
DC24V between 3(+) and 4(-) does not
appear.
Replace defective LED power
supply.
Error indicators of the lighting units flash
3 times continuously?
Voltage of the LED power supply output.
DC240V between 1(+) and 2(-) does not
appear.
Replace defective LED power
supply.
Error indicator of the lighting unit flashes
3 times continuously?
Voltage of the LED power supply output.
DC240V between 1(+) and 2(-) appears.
Replace lighting unit.
Lighting up, but not so bright or only
lights for a short time.
Error indicator of the lighting unit
flashes 4 or 5 or 6 times continuously.
Miswiring?
Correct the wiring.
Error indicator of the lighting unit flashes
4 or 5 or 6 times continuously. Some
LED chips are not lit up?
Replace the LED panel or the whole
lighting unit.
Error indicator of the lighting unit flashes
4 or 5 or 6 times continuously. Wiring
correct and all LED chips OK?
Replace the control board inside the
lighting unit.
Lampstand actuator not working.
The ignition key switch is not turned to
ON position?
Turn the ignition key switch.
Miswiring?
Correct the wiring.
Fuses on the right side of the control
panel(box) broken?
Check the "Fuse" page, replace the
broken fuse and remove the cause
of it.
DC12V is applied to the lampstand
actuator?
Replace the lampstand actuator.
Lampstand actuator is not working
or is too slow.
DC12V is applied to the lampstand
actuator but when trying to operate, the
voltage measured at battery is down?
Charge or replace the battery
DC12V is applied to the actuator, and
when trying to operate, the voltage
measured at battery is not down, but the
lampstand actuator is?
Replace the contact blocks behind
the actuator switch or cables.
TROUBLESHOOTING
Содержание GLOBUG GBX24B
Страница 58: ...PAGE 58 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 BLOCK DIAGRAM...
Страница 59: ...GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 PAGE 59 AC WIRING DIAGRAM...
Страница 60: ...PAGE 60 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 DC WIRING DIAGRAM...
Страница 62: ...PAGE 62 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 ENGINE WIRING DIAGRAM 1...
Страница 63: ...GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 PAGE 63 ENGINE WIRING DIAGRAM 2...
Страница 64: ...PAGE 64 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 LIGHTS WIRING DIAGRAM GBX24B...
Страница 65: ...GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 PAGE 65 LIGHTS WIRING DIAGRAM GBX24S...
Страница 66: ...PAGE 66 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 LIGHT TOWER WIRING DIAGRAM...
Страница 67: ...GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 PAGE 67 NOTES...