Page 10

 Do

cumen

t N

o. 020-306-20I

nstall

Proper Cover Installation

Improper Cover Installation

1

4

3

6

5

2

4.18 Attach Base to Cover 

Using the supplied hardware attach the base to the 

cover in the six available locations. Tighten each 

screw with 15lbs per inch of torque MAXIMUM 

to where they are flush with the plastic. DO NOT 

overtighten. To ensure a proper seal tighten each 

screw in a alternating pattern.

4.19 Installation Inspection 

Once final installation is completed visually inspect 

the Fiber Tap Plus. This includes but is not limited 

to the grommet being sealed and tightened 

correctly, each fiber adapter installed correctly 

and tightened, and the cover seated evenly on the 

base.

Installation (Cont.)

4.17 Place Cover Over Base 

Place the Fiber Tap Plus cover of the base in 

the orientation shown and ensure that the 

cover is seated correctly on the base before 

flipping the enclosure over safely. 

Содержание Fiber Tap Plus

Страница 1: ...ngs 5 3 1 Laser Light Warning 3 2 Laser Light Magnification Warning 3 3 Loose Fiber Warning 3 4 Sharp Edge Warning 3 5 Safety Glasses Warning 3 6 Electrical Shock Warning 3 7 Fiber Damage Warning 4 In...

Страница 2: ...location This guide is for installers who are familiar with fiber optic cable systems and their applications 1 Introduction 1 1 Product Description FTTX Network Planning Multilink s Fiber Tap Plus al...

Страница 3: ...LIP CENTRAL STRENGTH MEMBER CLAMP VIEW DDEN FLAT DROP CABLE INPUT GROMMET 2X WALL POLE MOUNT BOSSES m NO SHARP EDGES OR BURRS ALLOWED DRAWN BY MATERIAL FINISH XX 03 XXX 010 020 306 10REF BY MFG ENG UN...

Страница 4: ...us base Configuring grommet s for cable entry Installing connectors into internal adapters Attaching FTP base to cover using supplied hardware Safety Glasses Cut Resistant Gloves Scissors Side Cutters...

Страница 5: ...of fiber to stick to your clothing or fall into the work area where they can cause injury later Use tweezers to pick up broken cut pieces of fiber and place on a piece of tape that has been set aside...

Страница 6: ...ng This should result in 2 of exposed CSM 4 3 Install CSM Clamp and Tie Anchor Attach the CSM clamp to the base of the Fiber Tap Plus using the supplied hardware Be sure to install the clamp on the en...

Страница 7: ...g simultaneously slide the CSM under the CSM clamp 4 7 Install CSM Clamp to CSM Adjust the CSM under the CSM clamp so that the jacket is barely exposed and the 2 of CSM doesn t stick too far out of th...

Страница 8: ...he orientation using the supplied hardware Tighten each screw with 4lbs per inch of torque MAXIMUM to where they are flush with the plastic DO NOT overtighten To ensure a proper seal tighten each scre...

Страница 9: ...cap from the connector and plug in the connector into the internal adapter following the color fiber chart to that on the Fiber Tap Plus cover Repeat steps 4 13 4 14 the appropriate number of times ti...

Страница 10: ...rque MAXIMUM to where they are flush with the plastic DO NOT overtighten To ensure a proper seal tighten each screw in a alternating pattern 4 19 Installation Inspection Once final installation is com...

Страница 11: ...APC SM Field Installable Kit 066 025 10 SC UPC SM Field Installable Kit 066 024 10 LC APC SM Field Installable Kit 066 131 10 LC UPC SM Field Installable Kit 066 029 10 Tool Kit w Basic Fiber Cleaver...

Страница 12: ...il engsupport gomultilink com Tel 1 440 366 6966 Fax 1 440 366 6802 Email engsupport gomultilink com Tel 1 440 366 6966 Fax 1 440 366 6802 Email lasupport gomultilink com Europe Middle East Africa Lat...

Отзывы: