30
USAGE SYSTEM
PANEL OPENING
It is possible to open the grease filter cover panel
pulling it gently, as shown in
fig. 1
.
The panel is fixed with three magnets, there
are two safety cables to release in order to re-
move the panel from the product.
For the proper functioning, it is recommended to
install the product at a maximum distance of 2000
- 2100 mm, from the floor level.
Before proceeding with the installation of the ap-
pliance, check that all the components are not
damaged otherwise, please contact the dealer
and do not continue with the installation.
Use an air outlet pipe with a maximum length of
no more than 5 metres.
- Reduce the number of curves in the duct as
each curve reduces the suction efficiency equi-
valent to 1 linear meter. (E.g.: if 2 90° curves are
used, the length of the duct should not exceed 3
meters in length).
- Avoid drastic changes of direction.
- Use a duct with a diameter of 150mm constant
over the entire length.
- Use a duct of recognized and approved mate-
rial.
31
4V HOOD VERSION
INSTALLATION
For the installation of this product it is necessary
to create a plasterboard lowering, keeping at le-
ast 220mm distance between the same and the
solid ceiling.
The material supplied with the product allows it
to be installed on lowerings ranging from 220mm
(fig. 2) to 300mm (fig. 3) of distance between the
plasterboard and the solid ceiling.
It is necessary to make a circular opening in the
plasterboard, with a diameter equal to:
510mm
(fig. 4)
Using a level and a pencil, bring the four ends of
the holes created in the plasterboard directly into
the solid ceiling, see fig. 5, then draw perpendi-
cular lines as shown in fig. 6, in order to find the
center of the hole.
Position the drilling template supplied, aligning
the centre of the template with the centre of the
axes previously drawn (fig. 7). Using a pencil, tra-
ce the three holes to be made in the solid ceiling.
Before tracing the holes you can rotate the
drilling template in order to orient the air out-
let of the fan in the desired direction.
The po-
sition of the air outlet of the fan is indicated in the
drilling template.
Perform the three holes in the solid ceiling using
a helical tip with a diameter of 8mm.
Insert the metric inserts supplied into the holes
made.
Insert the threaded bars into the metric inserts
previously installed.
Screw the threaded bars using two nuts, as
shown in fig. 8, act in the nut below to screw the
threaded bar.
Insert an additional nut, a metal washer and a
plastic locking washer as shown in figure 9.
For
correct installation, position the metal washer
200mm high from the bottom surface of the
plasterboard, see figure 10.
Содержание SLT973
Страница 2: ...2 2...
Страница 3: ...3 1 3 2 4 5 3 6...
Страница 4: ...4 7 4 8 9 10 12 11...
Страница 5: ...5 13 5 14 16 17 15 18...
Страница 6: ...6 19 6 22 21 20...
Страница 22: ...22 10 Hiba eset n Menjen vissza a kezd lapra Koppintson a Claim Devices Eszk z k ig nyl se lehet s gre...
Страница 43: ...43 44 10 In case of following error Go back to the home page TAP Claim Devices...