SETTING UP AND CONFIGURING THE DEVICE
Conduit
®
Hardware Guide
31
Connector Information
Description
Manufacturer
P/N or Product Number
Contacts
3-pin connector with
crimp-style contacts
(female socket)
JST
JST-ZHR-3
SZH-002T-P0.5
Restoring User Defined Settings
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole.
To restore user defined settings for an
mPower device
:
1.
Locate the hole in the panel labeled RESET. The reset button is recessed into the housing.
2.
Use the pin to press in the button for between 3 to 29 seconds, then release the reset button.
If you do not press in the button long enough, the device will reset, but the user defined settings
will not be restored.
If you hold it too long (30 seconds or longer), factory default settings will be restored.
Note:
The RESET button is in the same location on all Conduit models.
Resetting the Device
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole.
The following is the default condition for the RESET button on the Conduit. You can program a change to the
behavior of the button if needed.
To reset the device:
1.
Find the hole in the front panel labeled RESET. The reset button is recessed into the case.
2.
For mPower models
: Use the pin to press the RESET button for less than 3 seconds, then release. The