POWER DRAW
20
Conduit
®
Hardware Guide
Radio Protocol
Idle Cellular
Connection no
data (Amps)
Average Tx
Current at Max
Power Passing
Data (Amps)
1
Peak Tx Current
(Amps)
2
Total Inrush
Charge (mC)
3
Total Inrush
Charge Duration
(mS)
24.0 Volts
LTE
0.096
0.227
0.300
2.75
7.43
1
Max Power
: The continuous current during maximum data rate with the radio transmitter at maximum power.
2
Peak Tx Current
: The average peak current during LTE connection.
3
Total Inrush Charge
: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load.
MTCDT-210 No Modem and No Accessory Cards
Voltage
No Connections
(Amps)
1
Ethernet
Connected only
(Amps)
2
Maximum
Current (Amps)
3
Total Inrush
Charge (mC)
4
Total Inrush
Charge Duration
(mS)
9.0 Volts
0.151
0.168
0.265
2.37
1.05
12.0 Volts
0.130
0.139
0.204
3.4
8.24
24.0 Volts
0.080
0.086
0.114
2.8
22.7
1
No Connections
: Typical measure performed with the unit powered up only–no connections to the device.
2
Ethernet Connected Only
: Typical power with Ethernet measured and the device attached to PC with Ethernet
cable only.
3
Maximum Current
: Maximum current measured with Ethernet connected, SD Card, and USB Device actively
running read/write script, USB Debug and Host active running find/command.
4
Total Inrush Charge
: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when