POWER DRAW
Conduit
®
Hardware Guide
17
Voltage
No Connections
(Amps)
1
Ethernet
Connected only
(Amps)
2
Maximum
Current (Amps)
3
Total Inrush
Charge (mC)
4
Total Inrush
Charge Duration
(mS)
24.0 Volts
0.081
0.086
0.114
2.48
14.6
1
No Connections
: Typical measure performed with the unit powered up only–no connections to the device.
2
Ethernet Connected Only:
Typical power with Ethernet measured and the device attached to PC with Ethernet
cable only.
3
Maximum Current:
Maximum current measured with Ethernet connected, SD Card, and USB Device actively
running read/write script, USB Debug and Host active running find/command.
4
Total Inrush Charge
: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load.