Paul Mueller Company Serving Beer Tank
Effective April 25, 2018
Owner’s Manual, Part No. 9865302
16
4.10 INLINER INSTALLATION
IMPORTANT: Inliners are designed for single use only!
1. Wash hands or wear gloves during this procedure.
2. Replace the sealing ring under the transit bush, if necessary, by removing the DN32 coupling nut at the
bottom of the tank and pushing the transit bush up inside. Be careful not to lose the transit bush’s pin.
2. Clean the connection ferrule inside the serving beer tank as described in Section 4.12.
3. Remove the inliner from the plastic bubble wrap, ensuring it does not come into contact with anything.
4. With the plastic connection of the inliner facing the connection ferrule inside the serving beer tank,
push the inliner down until the connection stays in place and is fully inserted in the connection ferrule
(see Figure 13).
5. Ensure the inliner is straight. Unroll the inliner 8 to 10 inches toward the back of the serving beer tank.
IMPORTANT: The inliner was packaged and shipped in such a way that after installation in the
beer tank, it can roll out to the back and then unfold to the side when it is filled (see Figure 4).
FIGURE 13: CONNECTING THE INLINER
7. Attach the piercing valve (see Figure 14A). Tighten the coupling nut with a spanner wrench (see
Figure 14B).