5.1 CONDITIONS FOR THE CORRECT OPERATION OF 

THE EQUIPMENT 

• The equipment should not be fed with hot water 

(T>40ºC).

• The temperature of the room must be between  4º and 

45ºC.

• For waters with a salinity level higher than 500 ppm, 

get in touch with your distributor so that they can advi-

se you for the most appropriate treatment for your case 

and thus ensure the proper operation of your equip-

ment, avoid damaging the components and guarantee 

the quality of the water provided.

5.2 PRE-INSTALLATION WARNINGS 

• If you need to adapt the facilities of your residence or 

business in order to be able to install the equipment in 

the designated space, any adaptation should be done 

following all applicable national regulations concerning 

the internal installation of water and power supplies.

• KINETICO equipment requires that a power outlet be 

placed at least one meter away.

• KINETICO equipment should not be installed laying 

down or at an angle. They should be placed over a flat 

surface in order to operate correctly and securely.

• The spot designated for its installation must be large 

enough to host the device, its accessories, connections 

and to allow for maintenance to be carried out comfor-

tably.

• Maintain a minimum separation of 10 cm from the si-

des and back wall to ensure the proper ventilation of the 

equipment.

• The equipment should never be installed outdoors.

ATTENTION: After its installation, the equipment 

should not be connected immediately to a power 

source. It should be left to rest for 2 hours once it has 

been installed in the desired spot. This is very impor-

tant in order to guarantee the proper operation of the 

system, since otherwise the compressor may end up 

damaged. The manufacturer will not be responsible 

for any of the damages suffered by the equipment in 

this case.

5.3. WARNINGS REGARDING THE USE OF THE EQUIP-

MENT

• If you are going to be absent for more than one week, 

close the equipment’s water inlet valve, empty it and 

disconnect it from the power supply. When you come 

back, connect the power supply to the equipment, open 

the inlet valve and empty the storage tank twice before 

consuming the water.

Attention: If the equipment has not worked or has 

not produced water for a prolonged period of time 

(more than one month), get in touch with the dis-

tributor in order to set up its appropriate sanitization 

and maintenance.

Attention: Particular attention must be paid to 

the regular cleaning and hygiene of the frontal 

dispensers, especially when carrying out their 

periodical maintenance and sanitization. For this, use 

a sanitising spray and single use paper towels (see the 

chapter on Sanitization). 

6.  OPERATION OF THE EQUIPMENT

6.1 IDENTIFICATION OF THE PRINCIPAL COMPONENTS

Control Panel

Front

Back

Hot water 

switch

Cold water 

switch

Nozzle 

Dispenser

Drip Tray

Connection for 

External Faucet for 

Room Temperature 

Water 

Cold water Drain

Water Inlet

Filter Housing 

Cover

Power Cable

Содержание columbia aqua FC-550

Страница 1: ...Technical Manual Service Booklet MU FC 550...

Страница 2: ......

Страница 3: ...0 5 PRIOR WARNINGS 6 OPERATION OF THE EQUIPMENT 7 HOW TO ACCESS THE FILTERS 8 TECHNICAL CHARACTERISTICS 9 INSTALLATION 10 CLEANING AND MAINTENANCE 11 SANITIZATION PROCEDURE 12 TROUBLESHOOTING 13 WARRA...

Страница 4: ...curity System for Hot Water ROOM TEMPERATURE Production of Room Temperature Water COLD Cold water production VENTILATION SYSTEM Forced ventilation system for the outdoors large loads and very warm reg...

Страница 5: ...ENT USED BY KINETICO 550 Depending on the KINETICO water dispenser model are availble with different types of treatment microcarbon and NANOFACT filtration 4 1 WHAT IS MICROCARBON Microcarbon filtrati...

Страница 6: ...d outdoors ATTENTION After its installation the equipment should not be connected immediately to a power source It should be left to rest for 2 hours once it has been installed in the desired spot Thi...

Страница 7: ...ded particles chloride their derivatives and other organic substances are retained and the water then passes through the NANOFACT filter where smaller particles are retained as well as viruses and bac...

Страница 8: ...r the back HOT switch must be in the ON position The frontal HOT will light up 2 Press the hot water icon 1 3 cup of the DISPENSA TION icon will turn red 3 Press the DISPENSATION icon Then hot water w...

Страница 9: ...ctly TOUCH TOUCH TOUCH DEACTIVATE Press and keep pres sed for more than 4 seconds the QUAN TITY ICON The white DISPENSATION icon will blink 3 times with a sound ding dong indicating that it has been d...

Страница 10: ...more than 5 se conds The DISPENSATION icon will light blue indica ting that cold water has been programmed as the de fault water type CHANGE FROM COLD TEMP TO ROOM TEMP Touch the AMBIENT room temp wa...

Страница 11: ...11...

Страница 12: ...CT reduces the flavour and smell of the water as well as its organic components It retains microorganisms as well as viruses and bacte ria Based on the characteristics of the water to be treated Opera...

Страница 13: ...s as necessary throughout the installation commissioning and maintenance of the equipment in order to avoid the risk of contaminating the equipment by not handling it properly Install the adapter from...

Страница 14: ...bling the equipment plan all the material that you will need to carry out the maintenance operations and the space ne cessary for it Work in a properly lit place in adequate hygienic conditions and wi...

Страница 15: ...off valve to the equipment enabling it to start up and allowing the sanitizing pro duct to go through Keep the inlet valve in that position and extract a cup of water for reach dispenser in order to...

Страница 16: ...ion The source is contaminated The rear switch COLD is in the OFF position The customer fills up bottles of cold water and empties the cold water tank The cold system is damaged or the re frigerant ga...

Страница 17: ...17...

Страница 18: ...t ensure that the installed equipment is suitable for improving the quality of the water to be treated in parti cular according to the characteristics of the equipment and the regulations in force The...

Страница 19: ...INSTALLER read this manual carefully If in doubt contact your dealer s Technical Support Service T A S The data marked with the symbol must be filled in by the technician installer and trans cribed by...

Страница 20: ...ANCE PREPARATION HYGIENISATION OTHER FULL MAINTENANCE PREPARATION HYGIENISATION OTHER TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP ORDINARY OUTSTANDING WARRANTY...

Страница 21: ...ARATION HYGIENISATION OTHER FULL MAINTENANCE PREPARATION HYGIENISATION OTHER TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP ORDINARY OUTSTANDING WARRANTY ORDINARY...

Страница 22: ...22 16 NOTES...

Страница 23: ...23 16 NOTES...

Страница 24: ...MU...

Отзывы: