MU columbia aqua FC-550 Скачать руководство пользователя страница 10

10

6.9 ACTIVATE / DEACTIVATE SOUNDS

To activate the sounds, touch the LOCK and QUANTI-

TY icons for more than 4 seconds. The portion of the 

DISPENSATION icon at the top right will flash 3 times 

accompanied by a ‘ring’ indicating that it has been ac-

tivated correctly.  

To deactivate the sounds, touch the LOCK and QUAN-

TITY icon for more than 4 seconds. The portion of the 

DISPENSATION icons below will flash 3 times accom-

panied by a ‘ring’ indicating that it has been deactivated 

correctly. 

6.10 CHANGE OF DEFAULT WATER TYPE

You can change the type of water that is dispensed by 

default if you do not select any type of water, which by 

default is factory water.

CHANGE FROM ROOM TEMP. TO COLD TEMP.

Press the COLD cold water icon for more than 5 se-

conds. The DISPENSATION icon will light blue, indica-

ting that cold water has been programmed as the de-

fault water type.

CHANGE FROM COLD TEMP. TO ROOM TEMP.

Touch the AMBIENT room temp. water icon for more 

than 5 seconds. The DISPENSATION icon will turn 

green, indicating that you have programmed room water 

as the default water type.

LOCK

QUANTITY

QUANTITY

LOCK

AMBIENT

COLD

7. HOW TO ACCESS THE FILTERS

Before changing the filters, close the inlet stopcock and 

depressurize the circuit by touching the DISPENSATION 

icon. Unplug the equipment from the power supply.

Remove the side cover of the equipment to access the 

filters.

Pull the filter you want to pull out slightly by the base 

and then, hold it firmly with one hand and turn it a quar-

ter turn to the left to remove it. 

 

Remove the protections from the new filter and insert it 

into the head by turning a quarter turn clockwise.

INLET 

STOP-

COCK

OPEN

CLOSED

Содержание columbia aqua FC-550

Страница 1: ...Technical Manual Service Booklet MU FC 550...

Страница 2: ......

Страница 3: ...0 5 PRIOR WARNINGS 6 OPERATION OF THE EQUIPMENT 7 HOW TO ACCESS THE FILTERS 8 TECHNICAL CHARACTERISTICS 9 INSTALLATION 10 CLEANING AND MAINTENANCE 11 SANITIZATION PROCEDURE 12 TROUBLESHOOTING 13 WARRA...

Страница 4: ...curity System for Hot Water ROOM TEMPERATURE Production of Room Temperature Water COLD Cold water production VENTILATION SYSTEM Forced ventilation system for the outdoors large loads and very warm reg...

Страница 5: ...ENT USED BY KINETICO 550 Depending on the KINETICO water dispenser model are availble with different types of treatment microcarbon and NANOFACT filtration 4 1 WHAT IS MICROCARBON Microcarbon filtrati...

Страница 6: ...d outdoors ATTENTION After its installation the equipment should not be connected immediately to a power source It should be left to rest for 2 hours once it has been installed in the desired spot Thi...

Страница 7: ...ded particles chloride their derivatives and other organic substances are retained and the water then passes through the NANOFACT filter where smaller particles are retained as well as viruses and bac...

Страница 8: ...r the back HOT switch must be in the ON position The frontal HOT will light up 2 Press the hot water icon 1 3 cup of the DISPENSA TION icon will turn red 3 Press the DISPENSATION icon Then hot water w...

Страница 9: ...ctly TOUCH TOUCH TOUCH DEACTIVATE Press and keep pres sed for more than 4 seconds the QUAN TITY ICON The white DISPENSATION icon will blink 3 times with a sound ding dong indicating that it has been d...

Страница 10: ...more than 5 se conds The DISPENSATION icon will light blue indica ting that cold water has been programmed as the de fault water type CHANGE FROM COLD TEMP TO ROOM TEMP Touch the AMBIENT room temp wa...

Страница 11: ...11...

Страница 12: ...CT reduces the flavour and smell of the water as well as its organic components It retains microorganisms as well as viruses and bacte ria Based on the characteristics of the water to be treated Opera...

Страница 13: ...s as necessary throughout the installation commissioning and maintenance of the equipment in order to avoid the risk of contaminating the equipment by not handling it properly Install the adapter from...

Страница 14: ...bling the equipment plan all the material that you will need to carry out the maintenance operations and the space ne cessary for it Work in a properly lit place in adequate hygienic conditions and wi...

Страница 15: ...off valve to the equipment enabling it to start up and allowing the sanitizing pro duct to go through Keep the inlet valve in that position and extract a cup of water for reach dispenser in order to...

Страница 16: ...ion The source is contaminated The rear switch COLD is in the OFF position The customer fills up bottles of cold water and empties the cold water tank The cold system is damaged or the re frigerant ga...

Страница 17: ...17...

Страница 18: ...t ensure that the installed equipment is suitable for improving the quality of the water to be treated in parti cular according to the characteristics of the equipment and the regulations in force The...

Страница 19: ...INSTALLER read this manual carefully If in doubt contact your dealer s Technical Support Service T A S The data marked with the symbol must be filled in by the technician installer and trans cribed by...

Страница 20: ...ANCE PREPARATION HYGIENISATION OTHER FULL MAINTENANCE PREPARATION HYGIENISATION OTHER TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP ORDINARY OUTSTANDING WARRANTY...

Страница 21: ...ARATION HYGIENISATION OTHER FULL MAINTENANCE PREPARATION HYGIENISATION OTHER TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP ORDINARY OUTSTANDING WARRANTY ORDINARY...

Страница 22: ...22 16 NOTES...

Страница 23: ...23 16 NOTES...

Страница 24: ...MU...

Отзывы: