406 – AL Open Load Digital Input 7
ZKP-Number: 2.8006.631
Line disruption on digital input 7
Yellow alarm – warning
Cause
Corrective action
Wiring faulty or no resistance
over switch.
1. Check wiring (→ Page 189).
2. Check target device input.
3. Contact Service.
407 – AL Open Load Digital Input 8
ZKP-Number: 2.8006.632
Line disruption on digital input 8
Yellow alarm – warning
Cause
Corrective action
Wiring faulty or no resistance
over switch.
1. Check wiring (→ Page 189).
2. Check target device input.
3. Contact Service.
408 – AL Open Load Emerg. Stop Input ESI
ZKP-Number: 2.8006.633
Open circuit at input for emergency stop.
Yellow alarm – warning
Cause
Corrective action
Wiring faulty or no resistance
over switch.
1. Check wiring (→ Page 189).
2. Check target device input.
3. Contact Service.
410 – LO U-PDU
ZKP-Number: 2.0141.921
Injector voltage too low (limit value 1)
Yellow alarm – warning
Cause
Corrective action
Cable damage or faulty power
supply.
1. Check wiring (→ Page 189).
2. Check supply.
3. Contact Service.
72 | Troubleshooting | MS150112/01E 2014-10
TIM-ID: 0000029153 - 005