7.12.5 Exhaust flaps – Actuator function check
Preconditions
☑
Engine is stopped and starting disabled.
☑
Operating voltage is not applied.
WARNING
Exhaust flaps close rapidly.
Risk of crushing hands!
• Using a suitable tool, check exhaust flaps by pressing the actuating linkage to its limit several
times and releasing it.
WARNING
Component is hot.
Risk of burning!
• Wear protective gloves.
Checking actuator function – mechanical
Note:
For installation position of exhaust flaps, refer to overview (→ Page 144).
1.
Remove guard plates of exhaust flaps.
2.
Check operability and ease of movement of
exhaust flaps and control linkage by mov-
ing the assembly at the points (arrows) and
make sure that there is no excessive play.
Result:
If exhaust flap is jamming, sluggish or has
too much play, contact Service.
3.
Check whether the internal spring pulls the
flap into the F-position:
• Fail-safe position for bypass flap and
EGR shutoff flap: opened.
• Fail-safe position for donor cylinder flap:
closed.
Result:
If the bypass flap/EGR shutoff flap is
closed or the donor cylinder flap is opened,
contact Service.
Checking operation of actuators – electrically
Note:
For installation position of exhaust flaps, refer to overview (→ Page 144).
1.
Switch on ECU.
2.
Learning cycle is carried out.
Result:
If the exhaust flaps don't move, contact Service.