341 – AL Open Load Cylinder A1
ZKP-Number: 1.8004.540
Injector wiring fault, cylinder A1
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A1.
1. Check injector wiring and solenoid valve.
2. Contact Service.
342 – AL Open Load Cylinder A2
ZKP-Number: 1.8004.541
Injector wiring fault, cylinder A2
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A2.
1. Check injector wiring and solenoid valve.
2. Contact Service.
343 – AL Open Load Cylinder A3
ZKP-Number: 1.8004.542
Injector wiring fault, cylinder A3
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A3.
1. Check injector wiring and solenoid valve.
2. Contact Service.
344 – AL Open Load Cylinder A4
ZKP-Number: 1.8004.543
Injector wiring fault, cylinder A4
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A4.
1. Check injector wiring and solenoid valve.
2. Contact Service.
345 – AL Open Load Cylinder A5
ZKP-Number: 1.8004.544
Injector wiring fault, cylinder A5
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A5.
1. Check injector wiring and solenoid valve.
2. Contact Service.
64 | Troubleshooting | MS150112/01E 2014-10
TIM-ID: 0000029153 - 005