176 – AL LifeData not available
Red alarm.
Associated parameter 2.4000.004
Cause
Corrective action
No (suitable) LifeData backup
system available following
timeout expiry after ECU reset.
Backup system has no LifeData
feature or CAN bus to backup
system is disrupted.
u
Contact Service. (Configuration fault)
177 – AL LifeData Restore Incomplete
Red alarm.
Associated parameter 2.4000.006
Cause
Corrective action
The fault is generated if a CRC is
faulty (specified for each
module) during the restoration
data upload (into ADEC) or if the
upload is incomplete.
u
Power up ECU, contact Service.
180 – AL CAN1 Node Lost
Yellow alarm.
Associated parameter 2.0500.680
Cause
Corrective action
Bus node (SAM or EMU) lost on
CAN bus 1.
u
Check operation of nodes and cabling. Busses (CAN bus 1 and
CAN bus 2) are redundant.
181 – AL CAN2 Node Lost
Yellow alarm.
Associated parameter 2.0500.681
Cause
Corrective action
Bus node (SAM or EMU) lost on
CAN bus 2.
u
Check operation of nodes and cabling. Busses (CAN bus 1 and
CAN bus 2) are redundant.
182 – AL CAN Wrong Parameters
Red alarm.
Associated parameter 2.0500.682
Cause
Corrective action
Incorrect parameter values
entered in data record.
u
Contact Service. (Configuration fault)
MS150097/01E 2013-10
| Troubleshooting | 97
TIM-ID: 0000027858 - 001