![MTU 8V4000L62FB Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/mtu/8v4000l62fb/8v4000l62fb_operating-instructions-manual_1852721078.webp)
1.4510.187 – Combined Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Combined alarm (for details,
refer to the source alarm).
u
Combined alarm (for details, refer to the source alarm).
1.4510.188 – Internal Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart knock module.
1.4510.189 – Error Camshaft
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from camshaft sensor
for anti-knock control.
u
Check cabling. Check sensor B 1.3 and replace if necessary.
1.4510.192 – Knock Sensor Error A1
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.193 – Knock Sensor Error A2
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.194 – Knock Sensor Error A3
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
78 | Troubleshooting | MS150097/01E 2013-10
TIM-ID: 0000027854 - 001