![MTU 8V4000L62FB Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/mtu/8v4000l62fb/8v4000l62fb_operating-instructions-manual_1852721063.webp)
112619 – LOLO T-Exhaust B9
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 137).
4. Check valve drive.
112620 – LOLO T-Exhaust B10
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 137).
4. Check valve drive.
112701 – HIHI T-Exhaust A1 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112702 – HIHI T-Exhaust A2 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112703 – HIHI T-Exhaust A3 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high.
1. Check emission values.
2. Check ignition timing(→ Page 137).
3. Check valve drive (exhaust valves do not close).
112704 – HIHI T-Exhaust A4 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
MS150097/01E 2013-10
| Troubleshooting | 63
TIM-ID: 0000027854 - 001